Computer-aided detection for the automated evaluation of pulmonary embolism

被引:4
作者
Li, Yan [1 ]
Dai, Yongliang [2 ]
Deng, Lei [1 ]
Yu, Nan [1 ]
Guo, Youmin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiol, Yanta Western Rd, Xian 710061, Shaanxi, Peoples R China
[2] Weap Ind 521 Hosp, Dept Radiol, Xian, Shaanxi, Peoples R China
关键词
Pulmonary embolism; mastora; qanadli; computer-aided detection; ANGIOGRAPHY; DIAGNOSIS;
D O I
10.3233/THC-171315
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: There are few quantitative studies that directly evaluate methods of determining pulmonary embolism (PE). New computer-aided detection (CAD) methods for measuring PE may help in defining the relationship of PE to right heart failure (RHF). OBJECTIVES: We used CAD to investigate the severity of PE and explored whether the severity of PE was associated with RHF. METHODS: A fully automatic calculation conducted by CAD was made of the embolism area/lumen area, which was used to evaluate the severity of the PE. The vascular obstruction index (VOI) was also used to evaluate PE, using the Mastora and Qanadli scores. Paired t tests were used to compare the severity of PE evaluated by Mastora or Qanadli score, to the severity determined by CAD. Correlation between the severity of the PE and RHF was also evaluated by Spearman's rank correlation analysis. RESULTS: There was no significant difference between the PE evaluated by Mastora compared with the measurement by CAD (P = 0.720), and also no difference between evaluation by Qanadli and automatic measurement by CAD (P = 0.617). The severity of PE evaluated by Mastora, Qanadli, and CAD had significant positive correlation with RHF (R = 0.75 P = 0.01, R = 0.69 P = 0.02, R = 0.80 P = 0.00). CONCLUSION: We found strong correlation between RHF and the severity of PE evaluated by CAD, and the method was found to be simple and reliable.
引用
收藏
页码:S135 / S142
页数:8
相关论文
共 50 条
  • [41] A Multistage Approach to Improve Performance of Computer-Aided Detection of Pulmonary Embolisms Depicted on CT Images: Preliminary Investigation
    Park, Sang Cheol
    Chapman, Brian E.
    Zheng, Bin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (06) : 1519 - 1527
  • [42] Computer-Aided Pulmonary Embolism Detection Using a Novel Vessel-Aligned Multi-planar Image Representation and Convolutional Neural Networks
    Tajbakhsh, Nima
    Gotway, Michael B.
    Liang, Jianming
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 62 - 69
  • [43] Computer-Aided Detection of Acute Pulmonary Embolism With 64-Slice Multi-Detector Row Computed Tomography: Impact of the Scanning Conditions and Overall Image Quality in the Detection of Peripheral Clots
    Dewailly, Marion
    Remy-Jardin, Martine
    Duhamel, Alain
    Faivre, Jean-Baptiste
    Pontana, Fraacois
    Deken, Valerie
    Bakai, Anne-Marie
    Remy, Jacques
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 23 - 30
  • [44] Automated computer-aided stenosis detection at coronary CT angiography: initial experience
    Elisabeth Arnoldi
    Mulugeta Gebregziabher
    U. Joseph Schoepf
    Roman Goldenberg
    Luis Ramos-Duran
    Peter L. Zwerner
    Konstantin Nikolaou
    Maximilian F. Reiser
    Philip Costello
    Christian Thilo
    European Radiology, 2010, 20 : 1160 - 1167
  • [45] Computer-Aided Detection of Cancer in Automated 3-D Breast Ultrasound
    Tan, Tao
    Platel, Bram
    Mus, Roel
    Tabar, Laszlo
    Mann, Ritse M.
    Karssemeijer, Nico
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (09) : 1698 - 1706
  • [46] A fully-automated computer-aided breast lesion detection and classification system
    Mutlu, Fuldem
    Cetinel, Gokcen
    Gul, Sevda
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 62
  • [47] Rapid image stitching and computer-aided detection for multipass automated breast ultrasound
    Chang, Ruey-Feng
    Chang-Chien, Kuang-Che
    Takada, Etsuo
    Huang, Chiun-Sheng
    Chou, Yi-Hong
    Kuo, Chen-Ming
    Chen, Jeon-Hor
    MEDICAL PHYSICS, 2010, 37 (05) : 2063 - 2073
  • [48] A Hybrid Lung and Vessel Segmentation Algorithm for Computer Aided Detection of Pulmonary Embolism
    Raghupathi, Laks
    Lakare, Sarang
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [49] The Use of Computer-Aided Detection for the Assessment of Pulmonary Arterial Filling Defects at Computed Tomographic Angiography
    Walsham, Anna C.
    Roberts, Heidi C.
    Kashani, Hany Mehdizadeh
    Mongiardi, Christopher N.
    Ng, Yuen-Li
    Patsios, Demetris A.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (06) : 913 - 918
  • [50] Computer-aided detection for screening mammography
    Astley, SM
    ACADEMIC RADIOLOGY, 2004, 11 (10) : 1139 - 1143