Peroxyoxalate chemiluminescence detection for capillary electrophoresis using membrane collection

被引:0
|
作者
Shultz, LL [1 ]
Shippy, S [1 ]
Nieman, TA [1 ]
Sweedler, JV [1 ]
机构
[1] Univ Illinois, Urbana, IL 61801 USA
关键词
capillary electrophoresis; postcolumn detection; membrane collection; peroxyoxalate chemiluminescence; radionuclide detection;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis (CE) is often limited by the need to measure nanoliter-volume, low-concentration analytes with selectivity and specificity. A post-column chemiluminescence (CL) method is described in which the capillary effluent is collected on a membrane which has been coated with a peroxyoxalate CL reagent, bis(2,4,6-trichlorophenyl)oxalate. After the CE run, the CL reaction is initiated on the membrane by applying hydrogen peroxide, a scientific charge-coupled device (CCD) camera images the resultant CL emission, and an electropherogram is reconstructed. This postcolumn detection scheme decouples the separation parameters from detection and allows longer lived CL reagents to be used with fast separations. As the reaction is catalyzed by imidazole, CL intensities and lifetimes resulting from imidazole-and non-imidazole-running buffers are compared. The postcolumn CL method is compared to on-line UV absorbance detection for a mixture of dansylated amino acids, with limits of detection (LODs) of 1.5 mu M (13 fmol) and separation efficiencies of 170,000 plates. The ability to preserve the sample on the membrane allows several selective detection schemes to be employed; the combination of postcolumn chemiluminescence and radionuclide detection from a single electrophoretic separation is demonstrated. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:329 / 337
页数:9
相关论文
共 50 条
  • [41] Development of capillary electrophoresis - chemiluminescence detection system
    Tsukagoshi, K
    BUNSEKI KAGAKU, 2003, 52 (01) : 1 - 13
  • [42] Improvement of a Capillary Electrophoresis–Chemiluminescence Detection System for Using a Polyacrylamide-Coated Capillary
    Kazuhiko Tsukagoshi
    Takahiro Kimura
    Toshinari Fuji
    Riichiro Nakajima
    Akihiro Arai
    Analytical Sciences, 2001, 17 : 345 - 347
  • [43] Indirect determination of enzyme kinetics using capillary electrophoresis with chemiluminescence detection
    Yavelak, Veronica M.
    Puckett, Libby G.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [44] A study on the system of nonaqueous microchip electrophoresis with on-line peroxyoxalate chemiluminescence detection
    Hu, Hong-Mei
    Yin, Xue-Feng
    Wang, Xiu-Zhong
    Shen, Hong
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (04) : 713 - 720
  • [45] MEMBRANE-FRACTION COLLECTION FOR CAPILLARY ELECTROPHORESIS
    CHENG, YF
    FUCHS, M
    ANDREWS, D
    CARSON, W
    JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 109 - 116
  • [46] PROTEIN IMMUNODETECTION USING CAPILLARY ELECTROPHORESIS WITH MEMBRANE-FRACTION COLLECTION
    WARREN, WJ
    CHENG, YF
    FUCHS, M
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1994, 12 (01): : 22 - &
  • [47] Improvement of a capillary electrophoresis-chemiluminescence detection system for using a polyacrylamide-coated capillary
    Tsukagoshi, K
    Kimura, T
    Fuji, T
    Nakajima, R
    Arai, A
    ANALYTICAL SCIENCES, 2001, 17 (02) : 345 - 347
  • [48] Determination of clenbuterol by capillary electrophoresis immunoassay with chemiluminescence detection
    Ji, Xinghu
    He, Zhike
    Ai, Xinping
    Yang, Hanxi
    Xu, Chuanlai
    TALANTA, 2006, 70 (02) : 353 - 357
  • [49] On-line indirect chemiluminescence detection in capillary electrophoresis
    Zhang, Y
    Huang, B
    Cheng, JK
    ANALYTICA CHIMICA ACTA, 1998, 363 (2-3) : 157 - 163
  • [50] Off-column chemiluminescence detection in capillary electrophoresis
    Lee, YT
    Whang, CW
    JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) : 379 - 384