摘要
Capillary electrophoresis (CE) is often limited by the need to measure nanoliter-volume, low-concentration analytes with selectivity and specificity. A post-column chemiluminescence (CL) method is described in which the capillary effluent is collected on a membrane which has been coated with a peroxyoxalate CL reagent, bis(2,4,6-trichlorophenyl)oxalate. After the CE run, the CL reaction is initiated on the membrane by applying hydrogen peroxide, a scientific charge-coupled device (CCD) camera images the resultant CL emission, and an electropherogram is reconstructed. This postcolumn detection scheme decouples the separation parameters from detection and allows longer lived CL reagents to be used with fast separations. As the reaction is catalyzed by imidazole, CL intensities and lifetimes resulting from imidazole-and non-imidazole-running buffers are compared. The postcolumn CL method is compared to on-line UV absorbance detection for a mixture of dansylated amino acids, with limits of detection (LODs) of 1.5 mu M (13 fmol) and separation efficiencies of 170,000 plates. The ability to preserve the sample on the membrane allows several selective detection schemes to be employed; the combination of postcolumn chemiluminescence and radionuclide detection from a single electrophoretic separation is demonstrated. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:329 / 337
页数:9
相关论文
共 50 条
  • [21] Determination of puerarin by capillary electrophoresis with chemiluminescence detection
    Han, Suqin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (14-15): : 1591 - 1594
  • [22] Determination of levodopa by capillary electrophoresis with chemiluminescence detection
    Zhao, Shulin
    Bai, Wenling
    Wang, Bing
    He, Min
    TALANTA, 2007, 73 (01) : 142 - 146
  • [23] Development of capillary electrophoresis - chemiluminescence detection system
    Tsukagoshi, K
    BUNSEKI KAGAKU, 2003, 52 (01) : 1 - 13
  • [24] Recent Advances in Chemiluminescence Detection for Capillary Electrophoresis
    Ji Xing-Hu
    Xu Qin-Feng
    He Zhi-Ke
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (11) : 1579 - 1586
  • [25] On-line indirect chemiluminescence detection in capillary electrophoresis
    Zhang, Y
    Huang, B
    Cheng, JK
    ANALYTICA CHIMICA ACTA, 1998, 363 (2-3) : 157 - 163
  • [26] Determination of clenbuterol by capillary electrophoresis immunoassay with chemiluminescence detection
    Ji, Xinghu
    He, Zhike
    Ai, Xinping
    Yang, Hanxi
    Xu, Chuanlai
    TALANTA, 2006, 70 (02) : 353 - 357
  • [27] Simple and Convenient Cell for Chemiluminescence Detection in Capillary Electrophoresis
    Kazuhiko Tsukagoshi
    Takeshi Nakamura
    Masahiko Hashimoto
    Riichiro Nakajima
    Analytical Sciences, 1999, 15 : 1047 - 1048
  • [28] Simple and convenient cell for chemiluminescence detection in capillary electrophoresis
    Tsukagoshi, K
    Nakamura, T
    Hashimoto, M
    Nakajima, R
    ANALYTICAL SCIENCES, 1999, 15 (11) : 1047 - 1048
  • [29] Determination of terbutaline sulfate by capillary electrophoresis with chemiluminescence detection
    Li, Shuting
    Wang, Janshi
    Zhao, Shulin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 155 - 158
  • [30] Determination of folic acid by capillary electrophoresis with chemiluminescence detection
    Zhao, SL
    Yuan, HY
    Xie, C
    Xiao, D
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1107 (1-2) : 290 - 293