Immunoelectron microscopy on epoxy sections without deplasticizing to detect glomerular immunoglobulin and complement deposits in renal diseases

被引:17
作者
Brorson, SH
Strom, EH
Skjorten, F
机构
[1] Department of Pathology, Ullevål Hospital, Oslo
[2] Department of Pathology, Ullevål Hospital, 0407 Oslo
关键词
epoxy resin; immunoelectron microscopy; renal biopsies; kidney; immunofluorescence microscopy;
D O I
10.1111/j.1699-0463.1997.tb00552.x
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Twenty renal biopsies were studied by immunoelectron microscopy (IEM) after embedding in epoxy resin. Immunogold labeling for immunoglobulins and complement C3 was performed on the epoxy sections, which were not subjected to any kind of etching or deplasticizing prior to the immunolabeling. The concentration of accelerator, DMP-30 (Tri (Dimethyl Amino Methyl) Phenol), was increased in the infiltration and embedding steps far beyond the values normally used to make immunolabeling of these antigens possible on epoxy sections. The sections were stained with tannic acid accompanied by uranyl acetate and lead citrate. Immunofluorescence (IF) for light microscopy was carried out on frozen sections of parallel tissue samples. Some cases with IgA-nephritis demonstrated a higher sensitivity for IEM than IF, in the sense that smaller amounts of antigen were detectable with IEM. Ultrastructural preservation with this method was approximately the same as that usually seen on epoxy-embedded material. By combining excellent immunolabeling with nearly optimal ultrastructural morphology in one procedure, this method is useful particularly in situations where the material available is limited, such as in studies of renal biopsies. As far as we know, this is the first time that immunoglobulins have been satisfactorily immunolabeled on epoxy sections without etching or deplasticizing.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 17 条
[1]   THE MORPHOLOGICAL AND IMMUNOHISTOCHEMICAL ANALYSIS OF RENAL BIOPSIES BY LIGHT AND ELECTRON-MICROSCOPY USING A SINGLE PROCESSING METHOD [J].
BOWDLER, AL ;
GRIFFITHS, DFR ;
NEWMAN, GR .
HISTOCHEMICAL JOURNAL, 1989, 21 (07) :393-402
[2]   Improved technique for immunoelectron microscopy. How to prepare epoxy resin to obtain approximately the same immunogold labeling for epoxy sections as for acrylic sections without any etching [J].
Brorson, SH ;
Skjorten, F .
MICRON, 1996, 27 (3-4) :211-217
[3]   The theoretical relationship of immunogold labeling on acrylic sections and epoxy sections [J].
Brorson, SH ;
Skjorten, F .
MICRON, 1996, 27 (3-4) :193-201
[4]   Mechanism for antigen detection on deplasticized epoxy sections [J].
Brorson, SH ;
Skjorten, F .
MICRON, 1995, 26 (04) :301-310
[5]  
BRORSON SH, IN PRESS MICRON
[6]  
Hayat M.A., 1989, PRINCIPLES TECHNIQUE, P24
[7]  
HAYAT MA, 1970, PRINCIPLES TECHNIQUE, V1, P140
[8]  
HAYAT MA, 1989, PRINCIPLES TECHNIQUE, P298
[9]   ULTRASTRUCTURAL POSTEMBEDDING IMMUNOGOLD LABELING - APPLICATIONS TO DIAGNOSTIC PATHOLOGY [J].
HERRERA, GA .
ULTRASTRUCTURAL PATHOLOGY, 1989, 13 (5-6) :485-499
[10]   ULTRASTRUCTURAL AND ELECTRON IMMUNOHISTOCHEMICAL FEATURES OF MEDULLARY-THYROID CARCINOMA [J].
HOLM, R ;
FARRANTS, GW ;
NESLAND, JM ;
SOBRINHOSIMOES, M ;
JORGENSEN, OG ;
JOHANNESSEN, JV .
VIRCHOWS ARCHIV A-PATHOLOGICAL ANATOMY AND HISTOPATHOLOGY, 1989, 414 (05) :375-384