Magnetic beads-based electrochemiluminescence assay for rapid and sensitive detection of telornerase activity

被引:32
|
作者
Zhou, Xiaoming
Xing, Da [1 ]
Zhu, Debin
Jia, Li
机构
[1] S China Normal Univ, MOE Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
基金
中国国家自然科学基金;
关键词
telomerase activity; TRAP; electrochemiluminescence; magnetic beads;
D O I
10.1016/j.elecom.2008.01.039
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Telomerase is a potential cancer marker. We developed a new and robust telomerase activity assay which combines the modified telomere repeat amplification protocol (TRAP) with magnetic beads-based electrochemiluminescence (ECL) detection. The high performance of this assay is related to the determination of telomerase activity from single cell levels, and ECL intensity is linear over the range of 1-1000 HeLa cell equivalents. The proposed telomerase assay offers a highly cost- and time-effective alternative to presently available telomerase assays, which are limited by tedious and complicated post-PCR detection. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:564 / 567
页数:4
相关论文
共 50 条
  • [31] Detection of Listeria monocytogenes based on teicoplanin functionalized magnetic beads combined with fluorescence assay
    Deng, Mei
    Chen, Guanhua
    Feng, Xiaoyan
    Wang, Zhengzheng
    Xu, Qian
    Xu, Hengyi
    MICROCHEMICAL JOURNAL, 2021, 171
  • [32] A homogeneous electrochemiluminescence immunoassay platform based on carbon quantum dots and magnetic beads enrichment for detection of thyroglobulin in serum
    Zhang, Yu
    Zheng, Zhen-Ni
    Lin, Xin-Hua
    Liu, Ai-Lin
    Lei, Yun
    TALANTA, 2024, 276
  • [33] Rapid and Sensitive Detection of Vinorelbine in the Urine of Tumor Patients by Capillary Electrophoresis with Tris(2,2′-bipyridyl)ruthenium(II)-based Electrochemiluminescence Assay
    Zhou, Qing-Wei
    Wu, Di
    Meng, Qin
    Tang, Hai-Bo
    Wei, Zheng-Ren
    Kuang, Ye
    Yin, Jian-Yuan
    Chen, Jia-Jun
    ANALYTICAL SCIENCES, 2013, 29 (07) : 757 - 760
  • [34] Rapid and Sensitive Detection of Vinorelbine in the Urine of Tumor Patients by Capillary Electrophoresis with Tris(2,2′-bipyridyl)ruthenium(II)-based Electrochemiluminescence Assay
    Qing-Wei Zhou
    Di Wu
    Qin Meng
    Hai-Bo Tang
    Zheng-Ren Wei
    Ye Kuang
    Jian-Yuan Yin
    Jia-Jun Chen
    Analytical Sciences, 2013, 29 : 757 - 760
  • [35] Sensitive cancer cell detection based on Au nanoparticles enhanced electrochemiluminescence of CdS nanocrystal film supplemented by magnetic separation
    Zhang, Huai-Rong
    Xia, Xing-Hua
    Xu, Jing-Juan
    Chen, Hong-Yuan
    ELECTROCHEMISTRY COMMUNICATIONS, 2012, 25 : 112 - 115
  • [36] Highly sensitive electrochemiluminescence biosensors for cholesterol detection based on mesoporous magnetic core–shell microspheres
    Juanjuan Zhang
    Shihong Chen
    Xingrong Tan
    Xia Zhong
    Dehua Yuan
    Yinfeng Cheng
    Biotechnology Letters, 2014, 36 : 1835 - 1841
  • [37] Magnetic Beads-Based Biological Mass Spectrometry Technology for Evaluating Therapeutic Efficacy of Acute Leukemia
    Liang Ting-Ting
    Wang Na
    Wang Guan-Jun
    Li Ai-Ling
    He Kun
    Wang Jie
    Cui Jiu-Gui
    Li Yan
    Li Wei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (02) : 233 - 236
  • [38] A gold nanoparticle based electrochemiluminescence probe for high sensitive telomerase activity analysis
    Zhou, Xiaoming
    Xing, Da
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 217 - +
  • [39] A rapid competitive ELISA assay of Okadaic acid level based on epoxy-functionalized magnetic beads
    Pang, Linjiang
    Quan, Haoran
    Sun, Ying
    Wang, Pingya
    Ma, Daifu
    Mu, Pengqian
    Chai, Tingting
    Zhang, Yiming
    Hammock, Bruce D.
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2019, 30 (01) : 1286 - 1302
  • [40] Different approaches for the detection of thrombin by an electrochemical aptamer-based assay coupled to magnetic beads
    Centi, S.
    Messina, G.
    Tombelli, S.
    Palchetti, I.
    Mascini, M.
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) : 1602 - 1609