Implantable Neural Probes for Brain-Machine Interfaces - Current Developments and Future Prospects

被引:57
作者
Choi, Jong-ryul [1 ]
Kim, Seong-Min [2 ,3 ]
Ryu, Rae-Hyung [4 ]
Kim, Sung-Phil [5 ]
Sohn, Jeong-Woo [2 ,3 ]
机构
[1] DGMIF, Med Device Dev Ctr, Daegu 41061, South Korea
[2] Catholic Kwandong Univ, Dept Med Sci, Coll Med, Kangnung 25601, South Korea
[3] Catholic Kwandong Univ, Biomed Res Inst, Int St Marys Hosp, Incheon 21711, South Korea
[4] DGMIF, Lab Anim Ctr, Daegu 41061, South Korea
[5] UNIST, Dept Human Factors Engn, Ulsan 44919, South Korea
基金
新加坡国家研究基金会;
关键词
Implantable neural probes; Brain-machine interface; Multi-channel electrodes; Neural probes with advanced materials; IN-VIVO; COMPUTER INTERFACE; ELECTRODE ARRAY; MICROELECTRODE ARRAYS; ELECTRICAL RECORDINGS; MULTIUNIT RECORDINGS; CORTICAL CONTROL; OPTICAL CONTROL; GRAPHENE; MULTICHANNEL;
D O I
10.5607/en.2018.27.6.453
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
A brain-machine interface (BMI) allows for direct communication between the brain and machines. Neural probes for recording neural signals are among the essential components of a BMI system. In this report, we review research regarding implantable neural probes and their applications to BMIs. We first discuss conventional neural probes such as the tetrode, Utah array, Michigan probe, and electroencephalography (ECoG), following which we cover advancements in next-generation neural probes. These next-generation probes are associated with improvements in electrical properties, mechanical durability, biocompatibility, and offer a high degree of freedom in practical settings. Specifically, we focus on three key topics: (1) novel implantable neural probes that decrease the level of invasiveness without sacrificing performance, (2) multi-modal neural probes that measure both electrical and optical signals, (3) and neural probes developed using advanced materials. Because safety and precision are critical for practical applications of BMI systems, future studies should aim to enhance these properties when developing next-generation neural probes.
引用
收藏
页码:453 / 471
页数:19
相关论文
共 160 条
[111]   INTRACORONARY STENTING FOR ACUTE AND THREATENED CLOSURE COMPLICATING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
ROUBIN, GS ;
CANNON, AD ;
AGRAWAL, SK ;
MACANDER, PJ ;
DEAN, LS ;
BAXLEY, WA ;
BRELAND, J .
CIRCULATION, 1992, 85 (03) :916-927
[112]   Spatial co-adaptation of cortical control columns in a micro-ECoG brain-computer interface [J].
Rouse, A. G. ;
Williams, J. J. ;
Wheeler, J. J. ;
Moran, D. W. .
JOURNAL OF NEURAL ENGINEERING, 2016, 13 (05)
[113]   A MEMS-based flexible multichannel ECoG-electrode array [J].
Rubehn, Birthe ;
Bosman, Conrado ;
Ostenveld, Robert ;
Fries, Pascal ;
Stieglitz, Thomas .
JOURNAL OF NEURAL ENGINEERING, 2009, 6 (03)
[114]   Tactile Frequency-Specific High-Gamma Activities in Human Primary and Secondary Somatosensory Cortices [J].
Ryun, Seokyun ;
Kim, June Sic ;
Lee, Hyeongrae ;
Chung, Chun Kee .
SCIENTIFIC REPORTS, 2017, 7
[115]  
Schalk Gerwin, 2011, IEEE Rev Biomed Eng, V4, P140, DOI 10.1109/RBME.2011.2172408
[116]  
Schwarz DA, 2014, NAT METHODS, V11, P670, DOI [10.1038/NMETH.2936, 10.1038/nmeth.2936]
[117]   The evolution of endovascular electroencephalography: historical perspective and future applications [J].
Sefcik, Roberta K. ;
Opie, Nicholas L. ;
John, Sam E. ;
Kellner, Christopher P. ;
Mocco, J. ;
Oxley, Thomas J. .
NEUROSURGICAL FOCUS, 2016, 40 (05)
[118]   Model validation of untethered, ultrasonic neural dust motes for cortical recording [J].
Seo, Dongjin ;
Carmena, Jose M. ;
Rabaey, Jan M. ;
Maharbiz, Michel M. ;
Alon, Elad .
JOURNAL OF NEUROSCIENCE METHODS, 2015, 244 :114-122
[119]   Prediction of Muscle Activities from Electrocorticograms in Primary Motor Cortex of Primates [J].
Shin, Duk ;
Watanabe, Hidenori ;
Kambara, Hiroyuki ;
Nambu, Atsushi ;
Isa, Tadashi ;
Nishimura, Yukio ;
Koike, Yasuharu .
PLOS ONE, 2012, 7 (10)
[120]   Statistical encoding model for a primary motor cortical brain-machine interface [J].
Shoham, S ;
Paninski, LM ;
Fellows, MR ;
Hatsopoulos, NG ;
Donoghue, JP ;
Normann, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) :1312-1322