Evaluation of infarcted murine heart function: comparison of prospectively triggered with self-gated MRI

被引:31
作者
Bovens, Sandra M. [1 ,2 ]
Boekhorst, Bernard C. M. Te [1 ,2 ]
den Ouden, Krista [1 ]
van de Kolk, Kees W. A. [1 ]
Nauerth, Arno [3 ]
Nederhoff, Marcel G. J. [1 ,2 ]
Pasterkamp, Gerard [1 ]
ten Hove, Michiel [1 ]
van Echteld, Cees J. A. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Expt Cardiol, NL-3584 CX Utrecht, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Bruker BioSpin MRI GmbH, Ettlingen, Germany
关键词
retrospective; cardiac MRI; infarct; self-gating; mouse; FAILING MOUSE HEARTS; MYOCARDIAL-INFARCTION; CARDIAC-FUNCTION; CINE; SYSTEM;
D O I
10.1002/nbm.1593
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Measurement of cardiac function is often performed in mice after, for example, a myocardial infarction. Cardiac MRI is often used because it is noninvasive and provides high temporal and spatial resolution for the left and right ventricle. In animal cardiac MRI, the quality of the required electrocardiogram signal is variable and sometimes deteriorates over time, especially with infarcted hearts or cardiac hypertrophy. Therefore, we compared the self-gated IntraGate-FLASH method with a prospectively triggered FLASH (fast low-angle shot) method in mice with myocardial infarcts (n = 16) and in control mice (n = 21). Mice with a myocardial infarct and control mice were imaged in a vertical 9.4-T MR system. Images of contiguous 1-mm slices were acquired from apex to base with prospective and self-gated methods. Data were processed to calculate cardiac function parameters for the left and right ventricle. The signal-to-noise and contrast-to-noise ratios were calculated in mid-ventricular slices. The signal-to-noise and contrast-to-noise ratios of the self-gated data were higher than those of the prospectively gated data. Differences between the two gating methods in the cardiac function parameters for both left and right ventricle (e. g. end-diastolic volumes) did not exceed the inter-observer variability in control or myocardial infarcted mice. Both methods gave comparable results with regard to the cardiac function parameters in both healthy control mice and mice with myocardial infarcts. Moreover, the self-gated method provided better signal-to-noise and contrast-to-noise ratios when the acquisition time was equal. In conclusion, the self-gated method is suitable for routine use in cardiac MRI in mice with myocardial infarcts as well as in control mice, and obviates the need for electrocardiogram triggering and respiratory gating. In both gating methods, more than 10 frames per cardiac cycle are recommended. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 13 条
[1]   Retrospective gating for mouse cardiac MRI [J].
Bishop, J ;
Feintuch, A ;
Bock, NA ;
Nieman, B ;
Dazai, J ;
Davidson, L ;
Henkelman, RM .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :472-477
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Automated rectilinear self-gated cardiac cine imaging [J].
Crowe, ME ;
Larson, AC ;
Zhang, Q ;
Carr, J ;
White, RD ;
Li, DB ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :782-788
[4]   Comparison between prospective and retrospective triggering for mouse cardiac MRI [J].
Heijman, Edwin ;
de Graaf, Wolter ;
Niessen, Petra ;
Nauerth, Arno ;
van Eys, Guillaume ;
de Graaf, Larry ;
Nicolay, Klaas ;
Strijkers, Gustav J. .
NMR IN BIOMEDICINE, 2007, 20 (04) :439-447
[5]   Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T [J].
Hiba, B ;
Richard, N ;
Janier, M ;
Croisille, P .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :506-513
[6]   HIGH-RESOLUTION HIGH-FIELD RODENT CARDIAC IMAGING WITH FLOW ENHANCEMENT SUPPRESSION [J].
ROSE, SE ;
WILSON, SJ ;
ZELAYA, FO ;
CROZIER, S ;
DODDRELL, DM .
MAGNETIC RESONANCE IMAGING, 1994, 12 (08) :1183-1190
[7]   Magnetic resonance microimaging for noninvasive quantification of myocardial function and mass in the mouse [J].
Ruff, J ;
Wiesmann, F ;
Hiller, KH ;
Voll, S ;
von Kienlin, M ;
Bauer, WR ;
Rommel, E ;
Neubauer, S ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (01) :43-48
[8]   Long-term stability of cardiac function in normal and chronically failing mouse hearts in a vertical-bore MR system [J].
Schneider, JE ;
Hulbert, KJ ;
Lygate, CA ;
Ten Hove, M ;
Cassidy, PJ ;
Clarke, K ;
Neubauer, S .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 17 (3-6) :162-169
[9]   Fast, high-resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system [J].
Schneider, JE ;
Cassidy, PJ ;
Lygate, C ;
Tyler, DJ ;
Wiesmann, F ;
Grieve, SM ;
Hulbert, K ;
Clarke, K ;
Neubauer, S .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) :691-701
[10]   Three-dimensional shape analysis of right ventricular remodeling in repaired tetralogy of Fallot [J].
Sheehan, Florence H. ;
Ge, Shuping ;
Vick, G. Wesley, III ;
Urnes, Kara ;
Kerwin, William S. ;
Bolson, Edward L. ;
Chung, Taylor ;
Kovalchin, John P. ;
Sahn, David J. ;
Jerosch-Herold, Michael ;
Stolpen, Alan H. .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (01) :107-113