Flap Monitoring using Thermal Imaging Camera: A Contactless Method

被引:13
|
作者
Rabbani, Muhammad Jibran [1 ]
Bhatti, Asif Zubair [1 ]
Shahzad, Ahmed [1 ]
机构
[1] Shalamar Hosp, Dept Burn & Plast Surg, Lahore, Pakistan
来源
JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN | 2021年 / 31卷 / 06期
关键词
Flir one; Flap monitoring; Thermal imaging camera; INFRARED THERMOGRAPHY; SALVAGE;
D O I
10.29271/jcpsp.2021.06.703
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the accuracy of the thermal imaging camera for the detection of vascular insult before the onset of permanent tissue damage. Study Design: Descriptive study. Place and Duration of Study: Department of Burn and Plastic Surgery, from July to December 2019. Methodology: The thermal image was used as an adjunct to clinical assessment in 84 flaps. Both pedicled and free flaps were performed in the study with a frequency of 68 (81%) and 16 (19%), respectively. Flap monitoring was performed regularly for five days by same team of surgeons and nurses. Flap vascularity was assessed by temperature gradient colour coding of thermal image taking the clinical assessment like colour, temperature, capillary refill, as a gold standard. Sensitivity and specificity of the thermal camera were calculated. Results: The age range of patients was from 5 years to 55 years. The diagnostic accuracy of thermal imaging camera was calculated to be 96.43% with a sensitivity of 98.7%, specificity of 75%. The positive predictive value was found to be 97.4%, negative predictive value was 85.7%, the false-negative value was 14.3%, and the false-positive value was 2.6%. Conclusion: Thermal imaging camera is an effective and useful adjunct for clinical assessment, as it is an easy and contactless technique.
引用
收藏
页码:703 / 706
页数:4
相关论文
共 50 条
  • [31] Assessment of temperature changes in carcasses in the early post-mortem period using the spectrum of a thermal imaging camera
    Listos, Piotr
    Gryzinska, Magdalena
    Panasiuk-Flak, Kinga
    Ciesielka, Marzanna
    Teresinski, Grzegorz
    MEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICE, 2021, 77 (05): : 253 - 257
  • [32] Development of a Thermal Camera Using a Low Noise High Speed Far Infrared Camera
    Chirila, C.
    Szolga, L. A.
    2019 IEEE 25TH INTERNATIONAL SYMPOSIUM FOR DESIGN AND TECHNOLOGY IN ELECTRONIC PACKAGING (SIITME 2019), 2019, : 183 - 193
  • [33] Review of Biomedical Applications of Contactless Imaging of Neonates Using Infrared Thermography and Beyond
    AlZubaidi, Abbas K.
    Ethawi, Yahya
    Schmoelzer, Georg M.
    Sherif, Sherif
    Narvey, Michael
    Seshia, Molly
    METHODS AND PROTOCOLS, 2018, 1 (04) : 1 - 20
  • [34] Flap Monitoring Using Transcutaneous Oxygen or Carbon Dioxide Measurements
    Halani, Sameer H.
    Hembd, Austin S.
    Li, Xingchen
    Kirby, Ben
    Beard, Courtney C.
    Haddock, Nicholas T.
    Suszynski, Thomas M.
    JOURNAL OF HAND AND MICROSURGERY, 2022, 14 (01) : 10 - 18
  • [35] Thermal imaging as a viable tool for monitoring plant stress
    Stoll, Manfred
    Jones, Hamlyn G.
    JOURNAL INTERNATIONAL DES SCIENCES DE LA VIGNE ET DU VIN, 2007, 41 (02): : 77 - 84
  • [36] Performance of infrared thermography and thermal stress test in perforator mapping and flap monitoring: A meta-analysis of diagnostic accuracy
    Raheman, J. Firas
    Rojoa, M. Djamila
    Patel, G. Nakul
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2021, 74 (09) : 2013 - 2025
  • [37] Imaging meets chemistry: The application of a thermal imaging camera in chemistry classes of secondary schools first stage
    Wagner, Tom
    Kempke, Torn
    CHEMKON, 2022, 29 (07) : 664 - 672
  • [38] Shelf temperature estimation of a vacuum freeze dryer by infrared thermal imaging camera
    Li, Hsing-Chieh
    Cheng, Hong-Ping
    Cheng, Chin-Chi
    QUANTITATIVE INFRARED THERMOGRAPHY JOURNAL, 2025,
  • [39] Fire service and first responder thermal imaging camera (TIC) advances and standards
    Konsin, Lawrence S.
    Nixdorff, Stuart
    INFRARED TECHNOLOGY AND APPLICATIONS XXXIII, 2007, 6542
  • [40] Application of spatial frequency response as a criterion for evaluating thermal imaging camera performance
    Lock, Andrew
    Amon, Francine
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XIX, 2008, 6941