Quantitative determination of poly(vinylpyrrolidone) by continuous-flow off-line pyrolysis-GC/MS

被引:44
作者
Antic, Vesna V. [1 ]
Antic, Malisa P. [1 ]
Kronimus, Alexander [2 ]
Oing, Katja [2 ]
Schwarzbauer, Jan [2 ]
机构
[1] Univ Belgrade, Fac Agr, Zemun Belgrade 11080, Serbia
[2] Rhein Westfal TH Aachen, Inst Geol & Geochem Petr & Coal, D-52056 Aachen, Germany
关键词
Off-line pyrolysis-GC/MS; Poly(vinylpyrrolidone); N-Vinylpyrrolidone; Personal care products; Pollution; Wastewater; River water; CHROMATOGRAPHY-MASS SPECTROMETRY; GAS CHROMATOGRAPHY; IDENTIFICATION; POLYMER; POLYVINYLPYRROLIDONE;
D O I
10.1016/j.jaap.2010.10.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly(vinylpyrrolidone) (PVP) is a widely used and environmentally stable synthetic polymer whose occurrence in wastewater is likely. However, an appropriate method for identification and quantification of this polymer in environmental samples is still lacking. Hence, in this study an analytical method based on continuous-flow off-line pyrolysis-gas chromatography/mass spectrometry (pyrolysis-GC/MS) was developed to identify and quantify PVP in waste and surface water samples. Pyrolysis of commercial PVP, of some personal care products, of spiked water samples as well as of wastewater samples and river water samples was performed in a tube furnace at 500 degrees C under a continuous nitrogen flow. GC/MS was used for identification of specific degradation products, while GC-FID analysis was performed for quantitative determination. The concentration of PVP was calculated on the basis of the main pyrolytic product, N-vinylpyrrolidone (NVP). Very good linear correlation between initial amounts of PVP and released amounts of NVP was obtained and used as external calibration. The detected level of PVP in investigated personal care products was 6.4 (hair gel), 0.8 (laundry detergent) and 1.4%(tablets for throat disinfection). Spiked water samples, wastewater samples and river water samples were pre-extracted with hexane and diethyl ether prior to pyrolysis. It was found that the recovery of spiked samples was 94.6 +/- 1.6% which indicated that pre-extraction did not provoke significant loss of polymer. Finally, application of the developed method on real environmental samples (river water) revealed that PVP was present in effluents from wastewater treatment plants in concentrations between 0.9 mg/L and 7 mg/L, as well as in river water affected by municipal sewage emissions with concentrations around 0.1 mg/L. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 23 条
[1]  
BARABAS ES, 1987, ENCY POLYM SCI ENG, V17, P198
[2]   Recent trends in analytical and applied pyrolysis of polymers [J].
Blazso, M .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1997, 39 (01) :1-25
[3]   Thermal degradation of polyvinylpyrrolidone on the surface of pyrogenic silica [J].
Bogatyrev, VM ;
Borisenko, NV ;
Pokrovskii, VA .
RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2001, 74 (05) :839-844
[4]  
Buhler V., 1998, Kollidon -Polyvinylpyrrolidone for the Pharmaceutical Industry, V4
[5]   Identification and determination of cross-linkers in cross linked poly(vinylpyrrolidone) by pyrolysis-gas chromatography mass spectrometry [J].
Cheng, TMH ;
Malawer, EG .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :468-475
[6]  
Cheng TMH, 1996, J AM SOC BREW CHEM, V54, P85
[7]   TRACE DETERMINATION OF HIGH-MOLECULAR-WEIGHT POLYVINYLPYRROLIDONE BY PYROLYSIS-GAS CHROMATOGRAPHY [J].
ERICSSON, I ;
LJUNGGREN, L .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1990, 17 (03) :251-260
[8]   STUDIES ON ISOLATED LIGNINS AND LIGNINS IN WOODY MATERIALS BY PYROLYSIS-GAS CHROMATOGRAPHY-MASS SPECTROMETRY AND OFF-LINE PYROLYSIS-GAS CHROMATOGRAPHY WITH FLAME IONIZATION DETECTION [J].
FAIX, O ;
MEIER, D ;
GROBE, I .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1987, 11 :403-416
[9]  
HELIOFF MW, 1991, Patent No. 5032391
[10]   On-line size exclusion chromatography-pyrolysis-gas chromatography-mass spectrometry for copolymer characterization and additive analysis [J].
Kaal, Erwin R. ;
Alkema, Geert ;
Kurano, Mitsuhiro ;
Geissler, Margit ;
Janssen, Hans-Gerd .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :182-189