Computational Fluid Dynamic Simulations of Aortic Coarctation Comparing the Effects of Surgical- and Stent-Based Treatments on Aortic Compliance and Ventricular Workload

被引:39
作者
Coogan, Jessica Shih [1 ]
Chan, Frandics Pak [2 ]
Taylor, Charles Anthony [1 ]
Feinstein, Jeffrey Allan [1 ,3 ]
机构
[1] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Pediat Cardiol, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
coarctation; simulation; CFD; stenting; surgery; stiffness; TERM FOLLOW-UP; ENDOVASCULAR STENTS; BLOOD-FLOW; IMPLANTATION; PRESSURE; MANAGEMENT; STIFFNESS; CHILDREN; REPAIR;
D O I
10.1002/ccd.22878
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: In this work, we examine the effects of stent-induced aortic stiffness on cardiac workload and blood pressure using computational fluid dynamic simulations. Background: Treatment of aortic coarctation (CoA) consists of either open, surgical repair or angioplasty with or without stenting. Although stenting is a minimally invasive alternative to surgery, aortic stiffness increases in the stented section. Concern over this increased stiffness has long been argued to be detrimental to the overall vascular health of the patient. Methods: MR imaging was performed on a 15-year-old female with CoA. A 3D model of the large thoracic arteries was created, and the heart and downstream vasculature were represented by lumped parameter models at the model inlet and outlets, respectively. A deformable wall assumption was used in conjunction with variable wall properties and tissue support, and 3D velocity, pressure, and wall dynamics were computed. The lumped parameter values and wall properties were tuned to match the mean flow and aortic deformation as measured by MRI. The CoA was then virtually removed from the model representing an end-to-end surgical correction. In a second model, the repaired section was prescribed to be nearly rigid, representing stenting. All other variables remained the same. Results: When compared to surgery, stenting resulted in clinically negligible increases in cardiac work (0.4%) and no change in mean blood pressure. Conclusions: This pilot study suggests CoA stenting may not affect cardiac work to any significant degree as is commonly believed in the clinical community. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:680 / 691
页数:12
相关论文
共 40 条
[31]   Efficient anisotropic adaptive discretization of the cardiovascular system [J].
Sahni, O. ;
Muller, J. ;
Jansen, K. E. ;
Shephard, M. S. ;
Taylor, C. A. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2006, 195 (41-43) :5634-5655
[32]   Endovascular stent treatment of aortic coarctation [J].
Sanders, SP .
AMERICAN HEART JOURNAL, 2000, 139 (06) :936-938
[33]   Single-beat estimation of end-systolic pressure-volume relation in humans - A new method with the potential for noninvasive application [J].
Senzaki, H ;
Chen, CH ;
Kass, DA .
CIRCULATION, 1996, 94 (10) :2497-2506
[34]  
Shah L, 2005, J INVASIVE CARDIOL, V11, P614
[35]   Patient-Specific Modeling of Cardiovascular Mechanics [J].
Taylor, C. A. ;
Figueroa, C. A. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2009, 11 :109-134
[36]   Long segment coarctation of the thoracic aorta: Treatment with multiple balloon-expandable stent implantation [J].
Thanopoulos, B ;
Triposkiadis, F ;
Margetakis, A ;
Mullins, CE .
AMERICAN HEART JOURNAL, 1997, 133 (04) :470-473
[37]   Outflow boundary conditions for three-dimensional finite element modeling of blood flow and pressure in arteries [J].
Vignon-Clementel, Irene E. ;
Figueroa, C. Alberto ;
Jansen, Kenneth E. ;
Taylor, Charles A. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2006, 195 (29-32) :3776-3796
[38]  
Wilson Nathan., 2001, MEDICAL IMAGE COMPUT, V2208, DOI [DOI 10.1007/3-540-45468-3_, 10.1007/3-540-45468-3_54, DOI 10.1007/3-540-45468-3_54]
[39]   Simulation of blood flow in deformable vessels using subject-specific geometry and spatially varying wall properties [J].
Xiong, Guanglei ;
Figueroa, C. Alberto ;
Xiao, Nan ;
Taylor, Charles A. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2011, 27 (07) :1000-1016
[40]   Intravascular ultrasound assessment of regional aortic wall stiffness, distensibility, and compliance in patients with coarctation of the aorta [J].
Xu, JP ;
Shiota, T ;
Omoto, R ;
Zhou, XD ;
Kyo, S ;
Ishii, M ;
Rice, MJ ;
Sahn, DJ .
AMERICAN HEART JOURNAL, 1997, 134 (01) :93-98