Image Quality in Low-dose Multidetector Computed Tomography: A Pilot Study to Assess Feasibility and Dose Optimization in Whole-body Bone Imaging

被引:23
作者
Gleeson, Tadhg G. [1 ]
Byrne, Brenda [2 ]
Kenny, Pat [2 ]
Last, Jason [4 ]
Fitzpatrick, Patricia [5 ]
O'Gorman, Peter [3 ]
Eustace, Steven J. [1 ]
机构
[1] Mater Misericordiae Univ Hosp, Dept Radiol & Diagnost Imaging, Dublin, Ireland
[2] Mater Misericordiae Univ Hosp, Dept Med Phys, Dublin, Ireland
[3] Mater Misericordiae Univ Hosp, Dept Haematol, Dublin, Ireland
[4] Univ Coll Dublin, Dept Anat, Dublin 2, Ireland
[5] Univ Coll Dublin, Sch Publ Hlth & Populat Sci, Dublin 2, Ireland
来源
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES | 2010年 / 61卷 / 05期
关键词
Computed tomography; Dose; Multiple myeloma; MULTIPLE-MYELOMA; CONVENTIONAL RADIOGRAPHY; CT; PELVIS; SPINE;
D O I
10.1016/j.carj.2010.01.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To study the impact of close parameters on image quality at whole-body low-dose multidetector computed tomography (CT) in an attempt to derive parameters that allow diagnostic quality images of the skeletal system without incurring significant radiation dose in patients referred for investigation of plasma cell dyscrasias. Methods: By using a single cadaver, 14 different whole-body low-dose CT protocols were individually assessed by 2 radiologists, blinded to acquisition parameters (kVp and mAs, reconstruction algorithm, close reduction software). Combinations of kVps that range from 80-140 kVp, and tube current time product from 14-125 mAs were individually scored by using a Likert scale from 1-5 in 4 separate anatomical areas (skull base, thoracic spine, pelvis, and distal femora). Correlation between readers scores and effective doses were obtained by using correlation coefficient statistical analysis, statistical significance was considered P < .01. Interobserver agreement was assessed by using a Bland and Altman plot. Interobserver agreement in each of the 4 anatomical areas was assessed by using kappa statistics. A single set of parameters was then selected for use in future clinical trials in a cohort of patients referred for investigation of monoclonal gammopathy, including multiple myeloma. Results: Several sets of exposure parameters allowed low-dose whole-body CT to be performed with effective doses similar to skeletal survey while preserving diagnostic image quality. Individual reader's and average combined scores showed a strong inverse correlation with effective dose (reader 1, r = 0.78, P = .0001; reader 2, r = -0.75, P = .0003); average combined scores r = -0.81, P < .0001). Bland and Altman plot of overall scores shows reasonable interobserver agreement, with a mean difference of 1.055. Conclusion: Whole-body low-dose CT can be used to obtain adequate CT image quality to assess normal osseous detail while delivering effective doses similar to those associated with conventional radiographic skeletal survey.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 12 条
[1]  
Amis E Stephen Jr, 2007, J Am Coll Radiol, V4, P272, DOI 10.1016/j.jacr.2007.03.002
[2]   Multiple myeloma: Clinical review and diagnostic imaging [J].
Angtuaco, EJC ;
Fassas, ABT ;
Walker, R ;
Sethi, R ;
Barlogie, B .
RADIOLOGY, 2004, 231 (01) :11-23
[3]   16-Row multidetector CT of the pelvis after iliosacrally inserted osteosynthetic screws: Experimental study of dose adjustment on preserved human cadaver specimens [J].
Begemann, P. G. ;
Mahnken, A. ;
Ries, T. ;
Briem, D. ;
Nolte-Ernsting, C. ;
Adam, G. ;
Koops, A. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (10) :1022-1027
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Can low-dose computed tomographic scan of the spine replace conventional radiography? An evaluation based on imaging myelomas, bone metastases, and fractures from osteoporosis [J].
Chassang, Madleen ;
Grimaud, Anne ;
Cucchi, J. M. ;
Novellas, Sebastien ;
Amoretti, Nicolas ;
Chevallier, Patrick ;
Bruneton, Jean Noeel .
CLINICAL IMAGING, 2007, 31 (04) :225-227
[6]   Guidelines for the use of imaging in the management of myeloma [J].
D'Sa, Shirley ;
Abildgaard, Niels ;
Tighe, Jane ;
Shaw, Penny ;
Hall-Craggs, Margaret .
BRITISH JOURNAL OF HAEMATOLOGY, 2007, 137 (01) :49-63
[7]   The role of anatomic and functional staging in myeloma: Description of Durie/Salmon PLUS staging system [J].
Durie, Brian G. M. .
EUROPEAN JOURNAL OF CANCER, 2006, 42 (11) :1539-1543
[8]   Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI) [J].
Gleeson, T. G. ;
Moriarty, J. ;
Shortt, C. P. ;
Gleeson, J. P. ;
Fitzpatrick, P. ;
Byrne, B. ;
McHugh, J. ;
O'Connell, M. ;
O'Gorman, P. ;
Eustace, S. J. .
SKELETAL RADIOLOGY, 2009, 38 (03) :225-236
[9]   Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT [J].
Gurung, J ;
Khan, MF ;
Maataoui, A ;
Herzog, C ;
Bux, R ;
Bratzke, H ;
Ackermann, H ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2005, 15 (09) :1898-1905
[10]   Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography [J].
Horger, M ;
Claussen, CD ;
Bross-Bach, U ;
Vonthein, R ;
Trabold, T ;
Heuschmid, M ;
Pfannenberg, C .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (02) :289-297