Technetium-99m tetrofosmin myocardial perfusion scan: Comparison of 1-day and 2-day protocols

被引:0
|
作者
Yong, TKA
Chambers, J
Maisey, MN
Fogelman, I
Clarke, SEM
机构
[1] GUYS HOSP,DEPT NUCL MED,LONDON SE1 9RT,ENGLAND
[2] GUYS HOSP,DEPT CARDIOL,LONDON SE1 9RT,ENGLAND
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 03期
关键词
technetium-99m tetrofosmin; protocols; coronary heart disease;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Nineteen patients with angina were recruited in this study for comparison of two 1-day protocols (stress-4 h rest and rest-4-h stress) and a 2-day protocol of technetium-99m tetrofosmin single-photon emission tomography (SPET). All of them underwent coronary angiography before or after the study. Exercise stress-rest study and rest-stress study were performed on two consecutive days. Delayed imaging was performed before the rest injection on the 2nd day. The stress study on the Ist day and rest study on the 2nd day were considered as a 2-day protocol. The I-day stress-rest protocol had a sensitivity of 100% (18/18) and an accuracy of 100% (19/19) in diagnosing ischaemic heart disease. The 1-day rest-stress protocol had a sensitivity of 94.4% (17/18) and an accuracy of 94.7% (18/19), These differences were not statistically significant (P=0.5 for sensitivity and accuracy). There was also no statistically significant difference between the two protocols in the diagnosis of ischaemic heart disease in individual artery territories. For the left descending artery, sensitivity was 88.2% (15/17) vs 76.5% (13/17) (P=0.48) for the stress-rest and rest-stress studies respectively. For the left circumflex artery, sensitivity was 90% (9/10) vs 80% (8/10) (P=1) and specificity was 66.7% (6/9) vs 77.8% (7/9) (P=1) respectively. For the right coronary artery, the sensitivity was 100% (16/16) vs 94% (15/16) (P=1) respectively, while the specificity was 33.3% (1/3) in both studies. Three hundred and forty-two myocardial segments were analysed. The stress-rest and 2-day protocols showed no statistically significant difference in the overall identification of segments with reversible ischaemia (48/141 segments vs 48/141 segments) or in respect of individual artery territories, There was also no significant difference in the identification of reversible ischaemic segments between the rest-stress and 2-day protocols (48/141 segments vs 34/135 segments, P=0.14), Abdominal activity was seen in 36 studies and interpretation was affected in five of them. Five patients with 24-h delayed images were evaluated and 24 segments with washout were identified. It is concluded that Tc-99m-tetrofosmin is a valuable new tracer in the investigation of ischaemic heart disease. The 1-day stress-rest protocol is as good as the 1-day rest-stress protocol in diagnosing coronary heart disease. The 1-day protocols and the 2-day protocol display no difference in identifying segments with reversible ischaemia.
引用
收藏
页码:320 / 325
页数:6
相关论文
共 50 条
  • [1] MYOCARDIAL IMAGING WITH TECHNETIUM-99M-TETROFOSMIN - COMPARISON OF ONE-DAY AND 2-DAY PROTOCOLS
    BRAAT, SH
    LECLERCQ, B
    ITTI, R
    LAHIRI, A
    SRIDHARA, B
    RIGO, P
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (10) : 1581 - 1585
  • [2] PERFUSION AND FUNCTION AT REST AND TREADMILL EXERCISE USING TECHNETIUM-99M-SESTAMIBI - COMPARISON OF ONE-DAY AND 2-DAY PROTOCOLS IN NORMAL VOLUNTEERS
    BORGESNETO, S
    COLEMAN, RE
    JONES, RH
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (07) : 1128 - 1132
  • [3] Parathyroid scintigraphy: Comparison of technetium-99m methoxyisobutylisonitrile and technetium-99m tetrofosmin studies
    Aigner, RM
    Fueger, GF
    Nicoletti, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (06): : 693 - 696
  • [4] An ultrashort 1-day protocol of Tc-99m tetrofosmin
    Hattori, N
    Tamaki, N
    Masuda, I
    Taniguchi, Y
    Kitano, H
    Kudoh, T
    Inubushi, M
    Tadamura, E
    Magata, Y
    Nakao, K
    Konishi, J
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (02) : 85 - 91
  • [5] Technetium-99m sestamibi/tetrofosmin myocardial perfusion scanning in cardiac and noncardiac sarcoidosis
    Eguchi, M
    Tsuchihashi, K
    Hotta, D
    Hashimoto, A
    Sasao, H
    Yuda, S
    Nakata, T
    Shijubou, N
    Abe, S
    Shimamoto, K
    CARDIOLOGY, 2000, 94 (03) : 193 - 199
  • [6] Lymphoscintigraphy and sentinel node localization in breast cancer patients:: A comparison between 1-day and 2-day protocols
    Yeung, HWD
    Cody, HS
    Turlakow, A
    Riedel, ER
    Fey, J
    Gonen, M
    Nuñez, R
    Yeh, SD
    Larson, SM
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (03) : 420 - 423
  • [7] Tomographic myocardial imaging with technetium-99m tetrofosmin - Comparison with tetrofosmin and Thallium planar imaging and with angiography
    Benoit, T
    Vivegnis, D
    Lahiri, A
    Itti, R
    Braat, S
    Rigo, P
    EUROPEAN HEART JOURNAL, 1996, 17 (04) : 635 - 642
  • [8] COMPARISON BETWEEN 1-DAY AND 2-DAY OCCLUSION TIMES IN PATCH TESTING
    GOH, CL
    WONG, WK
    NG, SK
    CONTACT DERMATITIS, 1994, 31 (01) : 48 - 50
  • [9] Comparative myocardial uptake of technetium-99m sestamibi and technetium-99m tetrofosmin one hour after stress injection
    Gremillet, E
    Champailler, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (11) : 1502 - 1510
  • [10] No gender bias in referral for coronary angiography after myocardial perfusion scintigraphy with technetium-99m tetrofosmin
    Jeanine E. Roeters van Lennep
    Judocus J. J. Borm
    Aeilko H. Zwinderman
    Ernest K. J. Pauwels
    Albert V. G. Bruschke
    Ernst E. van der Wall
    Journal of Nuclear Cardiology, 1999, 6 : 596 - 604