Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings

被引:17
作者
Habib, Syed Rashid [1 ]
Asiri, Waleed [2 ]
Hefne, Mohammed Jameel [2 ]
机构
[1] King Saud Univ, Coll Dent, Dept Prosthet Dent Sci, Riyadh 11545, Saudi Arabia
[2] King Saud Univ, Coll Dent, Riyadh 11545, Saudi Arabia
关键词
Zirconia copings; Zirconia crowns; Marginal fit of zirconia crowns; Adaptation of zirconia crowns; FIXED DENTAL PROSTHESES; FINITE-ELEMENT-ANALYSIS; FILM THICKNESS; CROWN COPINGS; STRESS-DISTRIBUTION; CERAMIC COPINGS; INTERNAL GAPS; MARGINAL FIT; IN-VITRO; CEMENTATION;
D O I
10.4047/jap.2014.6.6.444
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. To compare the accuracy of marginal and internal adaptation of zirconia (Zr) copings fabricated on anatomic (A), semi-anatomic (SA) and non-anatomic (NA) occlusal surface preparations. MATERIALS AND METHODS. 45 extracted bicuspid teeth were prepared for receiving zirconia crowns, with different occlusal preparation designs,A=15, SA=15 & NA=15. The Zr copings were fabricated by using CAD4DENT, CAD/CAM. The copings were adjusted, cemented and were cross sectioned centrally from buccal cusp tip to lingual cusp tip into mesial and distal halves, The copings were examined under electron microscope at x 200 magnification and the measurements were recorded at 9 predetermined areas in micrometers. RESULTS. Overall mean gap values for the three groups was found to be 155.93 +/- 33.98 mu m with Anatomical. Occlusal preparation design having the least gap value of 39.23 +/- 30.85 mu m showing the best adaptation among the groups, Post Hoc Tukey's test showed a statistically significant difference (P=.007) between the means of gap for A & NA preparation designs. Measurements recorded at 9 predetermined points showed variations for the three groups. CONCLUSION. Anatomical occlusal preparation designs resulted in better marginal and internal adaptation of Zr copings. There is a considerable variation between the measured marginal and internal gap values for the Zr copings fabricated by the (CAD4DENT-CAD/CAM). This variation may be associated with the lack of standardization of the preparation of teeth, computerized designing of the coping for each tooth, cement used, uniform pressure application during the cementation of the copings, sectioning of the copings and the microscopic measurements.
引用
收藏
页码:444 / 450
页数:7
相关论文
共 30 条
[1]   Fit of zirconia fixed partial denture: a systematic review [J].
Abduo, J. ;
Lyons, K. ;
Swain, M. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (11) :866-876
[2]   MARGINAL ADAPTATION OF THREE DIFFERENT ZIRCONIUM DIOXIDE THREE-UNIT FIXED DENTAL PROSTHESES [J].
Att, Wael ;
Komine, Futoshii ;
Gerds, Thomas ;
Strub, Joerg Rudolf .
JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (04) :239-247
[3]  
Azar MS, 2011, INT J PROSTHODONT, V24, P264
[4]  
Beuer F, 2009, QUINTESSENCE INT, V40, P243
[5]   Marginal and internal fits of fixed dental prostheses zirconia retainers [J].
Beuer, Florian ;
Aggstaller, Hans ;
Edelhoff, Daniel ;
Gernet, Wolfgang ;
Sorensen, John .
DENTAL MATERIALS, 2009, 25 (01) :94-102
[6]   Precision of fit: zirconia three-unit fixed dental prostheses [J].
Beuer, Florian ;
Naumann, Michael ;
Gernet, Wolfgang ;
Sorensen, John A. .
CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) :343-349
[7]   MEASUREMENT OF FORCES APPLIED DURING THE CLINICAL CEMENTATION OF DENTAL CROWNS [J].
BLACK, S ;
AMOORE, JN .
PHYSIOLOGICAL MEASUREMENT, 1993, 14 (03) :387-392
[8]   NONCAST TITANIUM RESTORATIONS IN FIXED PROSTHODONTICS [J].
BOENING, KW ;
WALTER, MH ;
REPPEL, PD .
JOURNAL OF ORAL REHABILITATION, 1992, 19 (03) :281-287
[9]   Evaluation of marginal and internal fit of ceramic crown copings [J].
Colpani, Juliana Tereza ;
Borba, Marcia ;
Della Bona, Alvaro .
DENTAL MATERIALS, 2013, 29 (02) :174-180
[10]  
Fransson B, 1985, Dent Mater, V1, P197, DOI 10.1016/S0109-5641(85)80019-1