Estimation of bacterial risk in extending the shelf life of PLT concentrates from 5 to 7 days

被引:40
作者
Lee, CK
Ho, PL
Lee, KY
Cheng, WW
Chan, NK
Tsoi, WC
Lin, CK
机构
[1] Hong Kong Red Cross Blood Transfus Serv, Hong Kong, Hong Kong, Peoples R China
[2] Univ Hong Kong, Ctr Infect, Hong Kong, Hong Kong, Peoples R China
[3] Univ Hong Kong, Dept Microbiol, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1046/j.1537-2995.2003.00456.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The use of bacterial culture to prevent bacterial contamination of blood components has renewed interest for extending the shelf life of PLT concentrates to 7 days after collection. STUDY DESIGN AND METHODS: This study was therefore conducted to determine the residual risk of bacterial contamination in PLT concentrates at the end of 5 and 7 days after collection in a center where all PLT concentrates are routinely screened by taking samples on Day 2 for culture. PLT units with no growth after 48 hours were sampled a second time on Day 5 or Day 7 after collection, followed by inoculation into aerobic culture bottles. The inoculated bottles were then monitored for up to 7 days at WC in an automatic monitoring and detection system. RESULTS: During a 16-month study period, a total of 6020 PLT concentrates were tested 5 days (Group A, n = 3010) and 7 days (Group B, n = 3010) after collection. Four units in each group (0.133%) were found to be contaminated. In 6 units, bacteria were seen on direct Gram stain. In addition, 5 of the associated RBC units grew the same organisms on culture. The organisms include three coagulase-negative staphylococci and five Propionibacterium acnes. The positive rate of routine short-term bacterial culture was 0.035 percent during the same study period. CONCLUSION: Despite routine short-term bacterial culture, a significant risk of bacterial contamination remains at 5 and 7 days after collection. For now, the shelf life of PLT concentrates should remain 5 days.
引用
收藏
页码:1047 / 1052
页数:6
相关论文
共 22 条
[1]   TRANSFUSION-RELATED SEPSIS AFTER PROLONGED PLATELET STORAGE [J].
ANDERSON, KC ;
LEW, MA ;
GORGONE, BC ;
MARTEL, J ;
LEAMY, CB ;
SULLIVAN, B .
AMERICAN JOURNAL OF MEDICINE, 1986, 81 (03) :405-411
[2]   STRATEGIES FOR THE AVOIDANCE OF BACTERIAL-CONTAMINATION OF BLOOD COMPONENTS [J].
BARRETT, BB ;
ANDERSEN, JW ;
ANDERSON, KC .
TRANSFUSION, 1993, 33 (03) :228-233
[3]   BACTERIAL SEPSIS SECONDARY TO PLATELET TRANSFUSION - AN ADVERSE EFFECT OF EXTENDED STORAGE AT ROOM-TEMPERATURE [J].
BRAINE, HG ;
KICKLER, TS ;
CHARACHE, P ;
NESS, PM ;
DAVIS, J ;
REICHART, C ;
FULLER, AK .
TRANSFUSION, 1986, 26 (04) :391-393
[4]   Growth of bacteria in inoculated platelets: implications for bacteria detection and the extension of platelet storage [J].
Brecher, ME ;
Holland, PV ;
Pineda, AA ;
Tegtmeier, GE ;
Yomtovian, R .
TRANSFUSION, 2000, 40 (11) :1308-1312
[5]   Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms [J].
Brecher, ME ;
Means, N ;
Jere, CS ;
Heath, D ;
Rothenberg, S ;
Stutzman, LC .
TRANSFUSION, 2001, 41 (04) :477-482
[6]   THE USE OF A CHEMILUMINESCENCE-LINKED UNIVERSAL BACTERIAL RIBOSOMAL-RNA GENE PROBE AND BLOOD-GAS ANALYSIS FOR THE RAPID DETECTION OF BACTERIAL-CONTAMINATION IN WHITE CELL-REDUCED AND NONREDUCED PLATELETS [J].
BRECHER, ME ;
BOOTHE, G ;
KERR, A .
TRANSFUSION, 1993, 33 (06) :450-457
[7]   Rapid identification of bacterially contaminated platelets using reagent strips: Glucose and pH analysis as markers of bacterial metabolism [J].
Burstain, JM ;
Brecher, ME ;
Workman, K ;
Foster, M ;
Faber, GH ;
Mair, D .
TRANSFUSION, 1997, 37 (03) :255-258
[8]  
Chaney R, 1999, TRANSFUSION MED, V9, P177
[9]   A PROSPECTIVE-STUDY OF SYMPTOMATIC BACTEREMIA FOLLOWING PLATELET TRANSFUSION AND OF ITS MANAGEMENT [J].
CHIU, EKW ;
YUEN, KY ;
LIE, AKW ;
LIANG, R ;
LAU, YL ;
LEE, ACW ;
KWONG, YL ;
WONG, S ;
NG, MH ;
CHAN, TK .
TRANSFUSION, 1994, 34 (11) :950-954
[10]   BACTERIAL PROLIFERATION IN PLATELET CONCENTRATES [J].
HEAL, JM ;
SINGAL, S ;
SARDISCO, E ;
MAYER, T .
TRANSFUSION, 1986, 26 (04) :388-390