Biomechanical effects of progressive anterior cervical decompression

被引:63
作者
Chen, TY [1 ]
Crawford, NR [1 ]
Sonntag, VKH [1 ]
Dickman, CA [1 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Div Neurol Surg, Spine Biomech Res Lab, Phoenix, AZ USA
关键词
biomechanics; discectomy; instability; kinematics; uncinate process; uncovertebral joint;
D O I
10.1097/00007632-200101010-00003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A repeated-measures in vitro flexibility test was performed. Objectives. To determine the biomechanical functions of tissues resected during anterior cervical decompression of various extents. Summary of Background Data. The biomechanical consequences of discectomy have been studied in vitro, and uncovertebral joint removal has been modeled numerically. No studies have assessed the relative biomechanical contributions of different anterior column structures. Methods. In seven human cadaver C4-T1 specimens, 20 motion segments were studied. After each destructive step, including discectomy, unilateral uncinate process removal, bilateral uncinate process removal, and posterior longitudinal ligament transection, torques were applied to four-level specimens while the angular motion was measured at each lever. Results. Angular range of motion and neutral zone increased by variable but statistically significant amounts after each progressive resection, most notably in flexion and extension. Each resection step caused progressively larger shifts (up to 23 mm) in the location of the axis of rotation. Uncovertebral joint resection caused the most significant changes in the observed angular coupling. Conclusions. Anterior cervical decompression significantly increases the instability and alters the kinematics of cervical motion segments. Each structure resected contributes to normal stability and kinematics, so as many structures as possible should be left intact during anterior decompression without fusion. Because flexion and extension were the modes of motion that increased most significantly after decompression, the primary function of a grafting technique or fixation device should be to limit these motions.
引用
收藏
页码:6 / 13
页数:8
相关论文
共 18 条
  • [1] Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5-C6 segment
    Clausen, JD
    Goel, VK
    Traynelis, VC
    Scifert, J
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) : 342 - 347
  • [2] A new technique for determining 3-D joint angles: the tilt/twist method
    Crawford, NR
    Yamaguchi, GT
    Dickman, CA
    [J]. CLINICAL BIOMECHANICS, 1999, 14 (03) : 153 - 165
  • [3] AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO
    CRAWFORD, NR
    BRANTLEY, AGU
    DICKMAN, CA
    KOENEMAN, EJ
    [J]. SPINE, 1995, 20 (19) : 2097 - 2100
  • [4] Crawford NR, 1998, BIOM HLTH R, V21, P539
  • [5] Construction of local vertebral coordinate systems using a digitizing probe - Technical note
    Crawford, NR
    Dickman, CA
    [J]. SPINE, 1997, 22 (05) : 559 - 563
  • [6] Crawford NR, 1998, J SPINAL DISORD, V11, P416
  • [7] Crawford NR, 2000, NEUROSURGERY SCI BAS, P1073
  • [8] Hadley M N, 1993, Neurosurg Clin N Am, V4, P45
  • [9] The role of anteromedial foraminotomy and the uncovertebral joints in the stability of the cervical spine - A biomechanical study
    Kotani, Y
    McNulty, PS
    Abumi, K
    Cunningham, BW
    Kaneda, K
    McAfee, PC
    [J]. SPINE, 1998, 23 (14) : 1559 - 1565
  • [10] BIOMECHANICAL EVALUATION OF THE EXTENSOR MUSCULATURE OF THE CERVICAL-SPINE
    NOLAN, JP
    SHERK, HH
    [J]. SPINE, 1988, 13 (01) : 9 - 11