Experimental analysis of a transfer function for the transient response of an evaporator in an absorption refrigeration GAX system

被引:6
作者
Garcia-Arellano, C. [1 ]
Garcia-Valladares, O. [1 ]
Gomez, V. H. [1 ]
机构
[1] Univ Nacl Autonoma Mexico, CIE, Temixco 62580, Morelos, Mexico
关键词
GAX; Transfer function; Operational stability; Simulation; Control; HEAT-PUMP SYSTEM; SOLAR-ENERGY; SIMULATION; SPEED; CYCLE; OPTIMIZATION; TEMPERATURE;
D O I
10.1016/j.applthermaleng.2010.05.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The absorption refrigeration systems (ARS) are highly non-linear, therefore presents oscillations on the responses of its components. The physical analysis of these systems is complex, particularly the transitory response. This paper presents the prediction response of an evaporator for an ARS GAX when occurs a modification in the refrigerant mass flow rate at the evaporator inlet section: this is obtained by means of a transfer function in order to determinate the cooling load and improve the stabilization time for different operation conditions. Different control instruments have been installed in different sections of GAX system in order to obtain an operational stability and carried out the theoretical and experimental analysis. The theoretical results show a close tendency with experimental data, errors below 2.5% are found. The results obtained between the heat load and the refrigerant mass flow rate at the evaporator will be used to design a control algorithm in order to obtain a complete autonomy system. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2026 / 2033
页数:8
相关论文
共 24 条
[1]   Experimental analysis of the scroll compressor performances varying its speed [J].
Aprea, C ;
Mastrullo, R ;
Renno, C .
APPLIED THERMAL ENGINEERING, 2006, 26 (10) :983-992
[2]   Experimental analysis of a transfer function for an air cooled evaporator [J].
Aprea, C ;
Renno, C .
APPLIED THERMAL ENGINEERING, 2001, 21 (04) :481-493
[3]  
Benjamin C., 2002, Automatic Control Systems, V8th
[4]  
CARMODY SA, 1993, THERMODYNAMICS DESIG, V30
[5]   Study and control of the optimal generation temperature in NH3-H2O absorption refrigeration systems [J].
Fernández-Seara, J ;
Vázquez, M .
APPLIED THERMAL ENGINEERING, 2001, 21 (03) :343-357
[6]   Theoretical and experimental evaluation of an indirect-fired GAX cycle cooling system [J].
Gomez, V. H. ;
Vidal, A. ;
Best, R. ;
Garcia-Valladares, O. ;
Velazquez, N. .
APPLIED THERMAL ENGINEERING, 2008, 28 (8-9) :975-987
[7]   Thermodynamic analysis of the absorption refrigeration system with geothermal energy:: an experimental study [J].
Keçeciler, A ;
Acar, HI ;
Dogan, A .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (01) :37-48
[8]   Numerical simulation of a variable speed refrigeration system [J].
Koury, RNN ;
Machado, L ;
Ismail, KAR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (02) :192-200
[9]   A new method for controlling refrigerant flow in automobile air conditioning [J].
Li, XQ ;
Chen, JP ;
Chen, ZJ ;
Liu, WH ;
Hu, W ;
Liu, XB .
APPLIED THERMAL ENGINEERING, 2004, 24 (07) :1073-1085
[10]  
MacArthur J.W., 1984, International Journal of Refrigeration, V7, P123