Computer-assisted surgery (CAS)-guided correction arthrodesis of the ankle and subtalar joint with retrograde nail fixation

被引:6
|
作者
Richter, M. [1 ]
机构
[1] Klinikum Coburg, D-96450 Coburg, Germany
来源
OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE | 2011年 / 23卷 / 02期
关键词
Ankle; Arthrodesis; Subtalar joint; Computer-assisted surgery; Retrograde nail; TOTAL KNEE ARTHROPLASTY; TIBIOTALOCALCANEAL ARTHRODESIS; POSTERIOR INSTRUMENTATION; INTRAMEDULLARY NAIL; PLACEMENT; SPINE; HIP;
D O I
10.1007/s00064-010-8070-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Restoration of a stable and plantigrade foot in deformities of the ankle and/or hindfoot and concomitant degenerative changes at the ankle and subtalar joint. Deformities of the ankle and/or hindfoot and concomitant degenerative changes at the ankle and subtalar joint. Active local infection or relevant arterial insufficiency. Prone position and posterolateral approach to ankle and subtalar joint. Placement of dynamic reference bases (DRB) in the tibia and through a stab incision in the talus or calcaneus. Two-dimensional (2D) image acquisition for navigation. Definition of axes of the tibia, calcaneus, and hindfoot, and of extent of correction. Exposition of ankle and subtalar joint and removal of remaining cartilage. Computer-assisted surgery (CAS)-guided correction and transfixation of the corrected position with 2.5 mm K-wires. Three-dimensional (3D) image acquisition for analysis of the accuracy of the correction and planning of the drilling for the retrograde nail. CAS-guided drilling insertion of the nail. Insertion of locking screws in the calcaneus, talus and tibia. 3D image acquisition for analysis of the accuracy of the correction implant position. Partial weight bearing (15 kg) in an orthosis (Vacuped) for 6 weeks, followed by full weight bearing in a stable standard shoe. From 1 September 2006 to 31 August 2008, 14 correction arthrodeses were performed. The accuracy was assessed by intraoperative 3D imaging. All achieved angles/translations were within a maximum deviation of 2A degrees/mm when compared to the planned correction. Complications that were associated with CAS were not observed. In all 14 cases completing follow-up, timely fusion was registered.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 47 条
  • [42] Is determination of the hip rotation center during computer-assisted surgery influenced by the pinless femoral sensor attachment method? An in vitro preliminary study comparing osseous pin fixation
    de Thomasson, E.
    Gouzy, S.
    Cloerec, F.
    Geais, L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (03) : 375 - 378
  • [43] Accuracy of the Yakebot dental implant robotic system versus fully guided static computer-assisted implant surgery template in edentulous jaw implantation: A preliminary clinical study
    Wang, Wenxue
    Xu, Hao
    Mei, Dongmei
    Zhou, Chen
    Li, Xiaojing
    Han, Ze'yu
    Zhou, Xiaobin
    Li, Xin
    Zhao, Baodong
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 309 - 316
  • [44] Open-sleeve templates for computer-assisted implant surgery at healed or extraction sockets: An in vitro comparison to closed-sleeve guided system and free-hand approach
    Li, Junying
    Meneghetti, Priscila Ceolin
    Galli, Matthew
    Mendonca, Gustavo
    Chen, Zhaozhao
    Wang, Hom-Lay
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (07) : 757 - 767
  • [45] Cone Beam Computed Tomography vs Multislice Computed Tomography in Computer-Aided Design/Computer-Assisted Manufacture Guided Implant Surgery Based on Three-Dimensional Optical Scanning and Stereolithographic Guides: Does Image Modality Matter?
    Widmann, Gerlig
    Fischer, Bastian
    Berggren, Johannes Peter Michael
    Dennhardt, Albina
    Schullian, Peter
    Reto, Bale
    Puelacher, Wolfgang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : 527 - 533
  • [46] Intraoperative Präzision mechanischer, elektromagnetischer, infrarot- und lasergeführter Navigationssysteme in der computergestützten ChirurgieIntraoperative precision of mechanical, electromagnetical, infrared and laser-guided navigation systems for computer-assisted surgery
    R. Marmulla
    M. Hilbert
    H. Niederdellmann
    Mund-, Kiefer- und Gesichtschirurgie, 1998, 2 (Suppl 1): : S145 - S148
  • [47] Technology integration and process management. Concept and implementation of a novel platform for one-staged diagnosis and therapy of acutely ill and injured patients as well as for elective, computer-assisted surgery [Technologieintegration und prozessmanagement. Konzept und implementierung einer neuartigen plattform für einzeitige diagnostik und therapie des akut kranken und verletzten sowie für elektive computerassistierte chirurgie (CAS)]
    Messmer P.
    Jacob A.L.
    Fries E.
    Gross T.
    Suhm N.
    Steinbrich W.
    Frede K.E.
    Schneider T.
    Regazzoni P.
    Der Unfallchirurg, 2001, 104 (10): : 1025 - 1030