Fixation of syndesmotic ruptures in 38 patients with a malleolar fracture - A randomized study comparing a metallic and a bioobsorbable screw

被引:53
作者
Kaukonen, JP
Lamberg, T
Korkala, O
Pajarinen, D
机构
[1] Paijat Hame Cent Hosp, Lahti, Finland
[2] Helsinki Univ Hosp, Helsinki, Finland
关键词
ankle fracture; syndesmosis rupture; polylevolactic acid; PLLA;
D O I
10.1097/01.bot.0000155313.50627.f6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To compare the performance of a metallic and a biodegradable screw in the fixation of tibia-fibula syndesmotic ruptures. Design: A randomized, prospective, and blinded study. Setting: Central hospital, Department Of Surgery. Patients: Forty consecutive patients with a clinically verified syndesmotic rupture in association with a malleolar fracture, of whom 38 completed the study. Intervention: After syndesmosis rupture was diagnosed, implant selection was performed intraoperatively by a strict randomization with sealed envelopes. Eighteen patients were treated with a metallic screw, and 20 with a bioabsorbable polylevolactic acid screw. The metallic screws were removed in a second operation at 8 weeks postoperatively. All patients had a treatment-blinded clinical and radiographic control after a mean follow-up of 35 (range 17-51) months. Main Outcome Measures: Return to previous physical activity level, evaluation of ankle stability, range of motion, circumference of the ankle, and a radiographic evaluation of both ankles including a measure of the talocrural, medial joint, and syndesmotic space widths. Results: More patients with a polylevolactic acid screw returned to their previous activity level, and there was less swelling in the ankles of these patients, but joint motion was similar between the groups. The mean values of syndesmotic and medial joint spaces were significantly higher in the radiographs of the operated ankles when compared to the uninjured ankle, but there was not a correlation to the type of screw used. Conclusions: Polylevolactic acid screws worked as well, or slightly better than, metallic ones in syndesmosis fixation in patients with an ankle fracture.
引用
收藏
页码:392 / 395
页数:4
相关论文
共 15 条
  • [1] BOSTMAN OM, 1995, CLIN ORTHOP RELAT R, P101
  • [2] Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw -: A case report
    Böstman, OM
    Pihlajamaki, HK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (12) : 1791 - 1794
  • [3] Polyglycolide bioabsorbable screws in the treatment of ankle fractures
    Hovis, WD
    Bucholz, RW
    [J]. FOOT & ANKLE INTERNATIONAL, 1997, 18 (03) : 128 - 131
  • [4] Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation
    Hovis, WD
    Kaiser, BW
    Watson, JT
    Bucholz, RW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) : 26 - 31
  • [5] A PERFORMANCE-TEST PROTOCOL AND SCORING SCALE FOR THE EVALUATION OF ANKLE INJURIES
    KAIKKONEN, A
    KANNUS, P
    JARVINEN, M
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (04) : 462 - 469
  • [6] STABILIZATION OF ANKLE SYNDESMOSIS INJURIES WITH A SYNDESMOSIS SCREW
    KAYE, RA
    [J]. FOOT & ANKLE, 1989, 9 (06): : 290 - 293
  • [7] Evaluation of the syndesmotic screw in low Weber C ankle fractures
    Kennedy, JG
    Soffe, KE
    Dalla Vedova, P
    Stephens, MM
    O'Brien, T
    Walsh, MG
    McManus, F
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (05) : 359 - 366
  • [8] Korkala O, 1999, ANN CHIR GYNAECOL FE, V88, P295
  • [9] LINDSJO U, 1985, CLIN ORTHOP RELAT R, P28
  • [10] Partio E K, 1992, J Orthop Trauma, V6, P209, DOI 10.1097/00005131-199206000-00013