Development of a validated stability-indicating LC method for nitazoxanide in pharmaceutical formulations

被引:13
|
作者
Malesuik, Marcelo Donadel [2 ]
Cardoso, Simone Goncalves [1 ]
Steppe, Martin [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Ciencias Farmaceut, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Rio Grande do Sul, Fac Farm, Program Posgrad Ciencias Farmaceut, BR-90046900 Porto Alegre, RS, Brazil
关键词
column liquid chromatography; stability-indicating method; validation; nitazoxanide;
D O I
10.1365/s10337-007-0454-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A reversed-phase liquid chromatographic (LC) method was developed for the assay of nitazoxanide (NTZ) in solid dosage formulations. An isocratic LC separation was performed on a Phenomenex Synergi Fusion C-18 column (250 mm x 4.6 mm, i.d., 4 mu m particle size) using a mobile phase of 0.1% o-phosphoric acid solution, pH 6.0: acetonitrile (45:55, v/v) at a flow rate of 1.0 mL min(-1). Detection was achieved with a photodiode array detector at 240 nm. The detector response for NTZ was linear over the concentration range from 2 to 100 mu g mL(-1) (r = 0.9999). The specificity and stability-indicating capability of the method were proved using stress conditions. The RSD values for intra-day precision were less than 1.0% for tablets and powder for oral suspension. The RSD values for inter-day precision were 0.6 and 0.7% for tablets and powder for oral suspension. The accuracy was 100.4% (RSD = 1.8%) for tablets and 100.9% (RSD = 0.3%) for powder for oral suspension. The limits of quantitation and detection were 0.4 and 0.1 mu g mL(-1). There was no interference of the excipients on the determination of the active pharmaceutical ingredient. The proposed method was precise, accurate, specific, and sensitive. It can be applied to the quantitative determination of drug in tablets and powder for oral suspension.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 50 条
  • [1] Development of a Validated Stability-Indicating LC Method for Nitazoxanide in Pharmaceutical Formulations
    Marcelo Donadel Malesuik
    Simone Gonçalves Cardoso
    Martin Steppe
    Chromatographia, 2008, 67 : 131 - 136
  • [2] Development and Validation of a Stability-Indicating LC Method for the Determination of Rupatadine in Pharmaceutical Formulations
    Daniele R. Nogueira
    Felipe B. D’Avila
    Clarice M. B. Rolim
    Sergio L. Dalmora
    Chromatographia, 2007, 66 : 915 - 919
  • [3] Development and validation of a stability-indicating LC method for the determination of rupatadine in pharmaceutical formulations
    Nogueira, Daniele R.
    D'Avila, Felipe B.
    Rolim, Clarice M. B.
    Dalmora, Sergio L.
    CHROMATOGRAPHIA, 2007, 66 (11-12) : 915 - 919
  • [4] Determination of rupatadine in pharmaceutical formulations by a validated stability-indicating MEKC method
    Nogueira, Daniele Rubert
    Sangoi, Maximiliano da Silva
    da Silva, Lucelia Magalhaes
    Todeschini, Vitor
    Dalmora, Sergio Luiz
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (16-17) : 3098 - 3105
  • [5] A validated stability-indicating LC method for zonisamide
    Pathare, Dnyandeo B.
    Jadhav, Ashok S.
    Shinqare, Murlidhar S.
    CHROMATOGRAPHIA, 2007, 66 (11-12) : 945 - 947
  • [6] A Validated Stability-Indicating LC Method for Zonisamide
    Dnyandeo B. Pathare
    Ashok S. Jadhav
    Murlidhar S. Shingare
    Chromatographia, 2007, 66 : 945 - 947
  • [7] Development and validation of a stability-indicating LC method for the assay of adapalene in bulk drug and pharmaceutical formulations
    Pujeri, S. S.
    Khader, A. M. A.
    Seetharamappa, J.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (06) : 585 - 590
  • [8] Development and validation of a stability-indicating LC method for the assay of adapalene in bulk drug and pharmaceutical formulations
    S. S. Pujeri
    A. M. A. Khader
    J. Seetharamappa
    Journal of Analytical Chemistry, 2012, 67 : 585 - 590
  • [9] A validated stability-indicating TLC-densitometric method for the determination of stanozolol in pharmaceutical formulations
    Syed Ghulam Musharraf
    Qamar ul Arfeen
    Wardah Mazhar
    Nayab Kanwal
    Chemistry Central Journal, 7
  • [10] A Validated and Stability-Indicating LC Assay Method for Valdecoxib
    Raju, T. Satyanarayana
    Raghavachary, K. S. V.
    Reddy, A. Raghupathi
    Varma, M. Satish
    Ravikumar, M.
    Swamy, P. Yadagiri
    CHROMATOGRAPHIA, 2009, 69 (5-6) : 507 - 511