Voltage Rollercoaster Filtering of Low-Mass Contaminants During Native Protein Analysis

被引:13
作者
McGee, John P. [1 ,2 ,3 ]
Melani, Rafael D. [1 ,2 ,3 ]
Goodwin, Michael [4 ]
McAlister, Graeme [4 ]
Huguet, Romain [4 ]
Senko, Michael W. [4 ]
Compton, Philip D. [1 ,2 ,3 ]
Kelleher, Neil L. [1 ,2 ,3 ]
机构
[1] Northwestern Univ, Chem Life Proc Inst, Dept Chem & Biol Engn, Prote Ctr Excellence, Evanston, IL 60208 USA
[2] Northwestern Univ, Chem Life Proc Inst, Dept Chem, Prote Ctr Excellence, Evanston, IL 60208 USA
[3] Northwestern Univ, Chem Life Proc Inst, Dept Mol Biosci, Prote Ctr Excellence, Evanston, IL 60208 USA
[4] Thermo Fisher Sci, San Jose, CA 95134 USA
基金
美国国家卫生研究院;
关键词
CHARGE-STATE DISTRIBUTION; SPACE-CHARGE; QUADRUPOLE; IONS; SPECTROMETRY; COMPLEXES; GAS;
D O I
10.1021/jasms.9b00037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Intact protein mass spectrometry (MS) via electrospray-based methods is often degraded by low-mass contaminants, which can suppress the spectral quality of the analyte of interest via space-charge effects. Consequently, selective removal of contaminants by their mobilities would benefit native MS if achieved without additional hardware and before the mass analyzer regions used for selection, analyte readout, or tandem MS. Here, we use the high-pressure multipole within the source of an Orbitrap Tribrid as the foundation for a coarse ion filter. Using this method, we show complete filtration of 2 mM polyethylene glycol (PEG-1000) during native MS of SILu mAb antibody present at a 200X lower concentration. We also show the generality of the process by rescuing 10 mu M tetrameric pyruvate kinase from 2 mM PEG-1000, asserting this voltage rollercoaster filtering (VRF) method for use in native MS as an efficient alternative to conventional purification methods.
引用
收藏
页码:763 / 767
页数:9
相关论文
共 22 条
[1]  
Amster IJ, 1996, J MASS SPECTROM, V31, P1325
[2]   Quality control in mass spectrometry-based proteomics [J].
Bittremieux, Wout ;
Tabb, David L. ;
Impens, Francis ;
Staes, An ;
Timmerman, Evy ;
Martens, Lennart ;
Laukens, Kris .
MASS SPECTROMETRY REVIEWS, 2018, 37 (05) :697-711
[3]  
Erwig MS, 2019, METHODS MOL BIOL, V1936, P37, DOI 10.1007/978-1-4939-9072-6_3
[4]   Note: Integration of trapped ion mobility spectrometry with mass spectrometry [J].
Fernandez-Lima, F. A. ;
Kaplan, D. A. ;
Park, M. A. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (12)
[5]   EQUILIBRIUM SPACE-CHARGE DISTRIBUTION IN A QUADRUPOLE ION-TRAP [J].
GUAN, SH ;
MARSHALL, AG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (02) :64-71
[6]   Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS [J].
Guevremont, R ;
Barnett, DA ;
Purves, RW ;
Vandermey, J .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4577-4584
[7]   Space Charge Induced Nonlinear Effects in Quadrupole Ion Traps [J].
Guo, Dan ;
Wang, Yuzhuo ;
Xiong, Xingchuang ;
Zhang, Hua ;
Zhang, Xiaohua ;
Yuan, Tao ;
Fang, Xiang ;
Xu, Wei .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (03) :498-508
[8]   Simple and universal tool to remove on-line impurities in mono- or two-dimensional liquid chromatography-mass spectrometry analysis [J].
Hesse, Anne-Marie ;
Marcelo, Paulo ;
Rossier, Jean ;
Vinh, Joelle .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :175-182
[9]   Cleaning up the masses: Exclusion lists to reduce contamination with HPLC-MS/MS [J].
Hodge, Kelly ;
Ten Have, Sara ;
Hutton, Luke ;
Lamond, Angus I. .
JOURNAL OF PROTEOMICS, 2013, 88 :92-103
[10]   Effects of solvent on the maximum charge state and charge state distribution of protein ions produced by electrospray ionization [J].
Iavarone, AT ;
Jurchen, JC ;
Williams, ER .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) :976-985