Competitive smartphone-based portable electrochemical aptasensor system based on an MXene/cDNA-MB probe for the determination of Microcystin-LR

被引:23
|
作者
Fan, Liang [1 ]
Huang, Jinhui Jeanne [1 ]
Liao, Jianjun [2 ]
机构
[1] Nankai Univ, Coll Environm Sci & Engn, Sino Canada R&D Ctr Water & Environm Safety, Tianjin 300350, Peoples R China
[2] Hainan Univ, Sch Ecol & Environm Sci, Haikou 570228, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
Smartphone; Portable electrochemical system; Microcystin-LR; Competitive aptasensor; Mxene; BIOSENSOR; TOXICITY;
D O I
10.1016/j.snb.2022.132164
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A competitive smartphone-based portable electrochemical aptamer sensing system was developed for MC-LR detection. The platform was composed with a smartphone-controlled portable electrochemical system, a smartphone with custom application and a screen-printed carbon electrode (SPCE). The portable electrochemical system consisted a homemade ARM STM32 with chronoamperometry (CA), cyclic voltammetry (CV) and square wave voltammetry (SWV) modules that had a similar performance to commercial electrochemical workstations. The control of the portable electrochemical system, reception and visualization of the assay results were implemented by a smartphone. SPCE was modified by in situ electrodeposition with gold nanoparticles (AuNPs) and reduced graphene oxide (rGO). Subsequently, the aptamer was incubated onto the SPCE through Au-S bonds. The complementary DNA labeled with methylene blue (cDNA-MB) was conjugated onto the surface of MXene to form the probe for signal amplification. The competitive aptasensor was accomplished when the probe was complemented with the aptamer. The fabricated system exhibited the outstanding capability for the determination of MC-LR over a range of 0.0001-5 nM with a limit of detection of 4 x 10(-5) nM. Furthermore, the system demonstrated acceptable stability, reproducibility, specificity and high recovery rate. The smartphone-based competitive aptasensor system exhibited the merits of portability, low-cost and fast-response to satisfy the demand for on-site detection of MC-LR.
引用
收藏
页数:9
相关论文
共 16 条
  • [11] Construction of portable electrochemical immunosensors based on graphene hydrogel@polydopamine for microcystin-LR detection using multi-mesoporous carbon sphere-enzyme labels
    Gan, Cuifen
    Sun, Zihong
    Ling, Li
    He, Zuyu
    Lei, Hongtao
    Liu, Yingju
    RSC ADVANCES, 2016, 6 (57) : 51662 - 51669
  • [12] Visible-light-driven photoelectrochemical aptasensor based on reduced graphene oxide/Ti-Fe-O nanotube arrays for highly sensitive and selective determination of microcystin-LR
    Lu, Hanxing
    Wang, Guoqiang
    Dai, Ruihua
    Ding, Xue
    Liu, Meichuan
    Sun, Huanhuan
    Sun, Caiqin
    Zhao, Guohua
    ELECTROCHIMICA ACTA, 2019, 324
  • [13] Smartphone-based portable electrochemical-colorimetric dual-mode biosensor for glucose detection in a co-reaction system
    Xu, Jiaqi
    Shen, Jianing
    Zhang, Bo
    Zhang, Yao
    Lv, Xiaoqing
    Zhu, Guixian
    ELECTROCHIMICA ACTA, 2024, 481
  • [14] Cost-effective, wireless, and portable smartphone-based electrochemical system for on-site monitoring and spatial mapping of the nitrite contamination in water
    Xu, Ke
    Chen, Qiulin
    Zhao, Yuanyuan
    Ge, Chengjun
    Lin, Shiwei
    Liao, Jianjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 319
  • [15] Portable smartphone-based colorimetric system for simultaneous on-site microfluidic paper-based determination and mapping of phosphate, nitrite and silicate in coastal waters
    Ahmad Manbohi
    Seyyed Hamid Ahmadi
    Environmental Monitoring and Assessment, 2022, 194
  • [16] Portable smartphone-based colorimetric system for simultaneous on-site microfluidic paper-based determination and mapping of phosphate, nitrite and silicate in coastal waters
    Manbohi, Ahmad
    Ahmadi, Seyyed Hamid
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (03)