A hydrogen peroxide biosensor based on direct electron transfer from hemoglobin to an electrode modified with Nafion and activated nanocarbon

被引:39
作者
Song, Jie [1 ,2 ]
Xu, JiMing [2 ]
Zhao, PuSu [2 ]
Lu, LuDe [1 ]
Bao, JianChun [1 ]
机构
[1] Nanjing Univ Sci & Technol, Mat Chem Lab, Nanjing 210094, Jiangsu, Peoples R China
[2] Huaiyin Normal Univ, Jiangsu Key Lab Chem Low Dimens Mat, Huaian 223300, Jiangsu, Peoples R China
关键词
Hydrogen peroxide biosensor; AC/NF composite film; Hemoglobin; Direct electron transfer; DIRECT ELECTROCHEMISTRY; CARBON; BIOELECTROCATALYSIS; BIOELECTROCHEMISTRY; ELECTROCATALYSIS; IMMOBILIZATION; GLUCOSE;
D O I
10.1007/s00604-010-0470-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor for hydrogen peroxide (HP) was developed by immobilizing hemoglobin on a glassy carbon electrode modified with activated carbon nanoparticles/Nafion. The characteristics of the sensor were studied by UV-vis spectroscopy and electrochemical methods. The immobilized Hb retained its native secondary structure, undergoes direct electron transfer (with a heterogeneous rate constant of 3.37 +/- 0.5 s(-1)), and displays excellent bioelectrocatalytic activity to the reduction of HP. Under the optimal conditions, its amperometric response varies linearly with the concentration of HP in the range from 0.9 mu M to 17 mu M. The detection limit is 0.4 mu M (at S/N = 3). Due to the commercial availability and low cost of activated carbon nanoparticles, it can be considered as a useful supporting material for construction of other third-generation biosensors.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 36 条
[1]  
BOND AM, 1980, MODERN POLAROGRAPHIC, P27
[2]   Direct electron transfer and bioelectrocatalysis of hemoglobin at a carbon nanotube electrode [J].
Cai, CX ;
Chen, J .
ANALYTICAL BIOCHEMISTRY, 2004, 325 (02) :285-292
[3]   Hemoglobin on Phosphonic Acid Terminated Self-Assembled Monolayers at a Gold Electrode: Immobilization, Direct Electrochemistry, and Electrocatalysis [J].
Chen, Yu ;
Jin, Bo ;
Guo, Li-Rong ;
Yang, Xiao-Jing ;
Chen, Wei ;
Gu, Gang ;
Zheng, Li-Min ;
Xia, Xing-Hua .
CHEMISTRY-A EUROPEAN JOURNAL, 2008, 14 (34) :10727-10734
[4]   Direct electrochemistry and electrocatalysis of hemoglobin at three-dimensional gold film electrode modified with self-assembled monolayers of 3-mercaptopropylphosphonic acid [J].
Chen, Yu ;
Yang, Xiao-Jing ;
Guo, Li-Rong ;
Li, Jing ;
Xia, Xing-Hua ;
Zheng, Li-Min .
ANALYTICA CHIMICA ACTA, 2009, 644 (1-2) :83-89
[5]   Investigation of biosensor signal bioamplification:: Comparison of direct electrochemistry phenomena of individual Laccase, and dual Laccase-Tyrosinase copper enzymes, at a Sonogel-Carbon electrode [J].
ElKaoutit, Mohammed ;
Naranjo-Rodriguez, Ignacio ;
Riffi Temsamani, Khalid ;
Dominguez, Manuel ;
Luis Hidalgo-Hidalgo de Cisneros, Jose .
TALANTA, 2008, 75 (05) :1348-1355
[6]   Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP sephadex membrane [J].
Fan, CH ;
Wang, HY ;
Sun, S ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2850-2854
[7]   A SPECTROPHOTOMETRIC STUDY OF IONIZATIONS IN METHAEMOGLOBIN [J].
GEORGE, P ;
HANANIA, G .
BIOCHEMICAL JOURNAL, 1953, 55 (02) :236-243
[8]   FERROCENE AND FERRICENIUM ION AS VERSATILE PHOTOMETRIC TITRANTS OF H2O2 AND D-GLUCOSE IN THE PRESENCE OF PEROXIDASE AND GLUCOSE-OXIDASE - A FERROCENE-PEROXIDASE STAIRWAY [J].
GORAL, VN ;
NELEN, MI ;
RYABOV, AD .
ANALYTICAL LETTERS, 1995, 28 (12) :2139-2148
[9]   OXYGEN-TOXICITY, OXYGEN RADICALS, TRANSITION-METALS AND DISEASE [J].
HALLIWELL, B ;
GUTTERIDGE, JMC .
BIOCHEMICAL JOURNAL, 1984, 219 (01) :1-14
[10]   Amperometric biosensor for hydrogen peroxide and nitrite based on hemoglobin immobilized on one-dimensional gold nanoparticle [J].
Hong, Jianmin ;
Dai, Zhihui .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) :222-226