Data center holistic demand response algorithm to smooth microgrid tie-line power fluctuation

被引:44
作者
Yang, Ting [1 ]
Zhao, Yingjie [1 ]
Pen, Haibo [1 ]
Wang, Zhaoxia [2 ]
机构
[1] Tianjin Univ, Minist Educ, Key Lab Smart Grid, Tianjin 300072, Peoples R China
[2] Inst High Performance Comp Agcy Sci Technol & Res, Singapore 138632, Singapore
基金
中国国家自然科学基金;
关键词
Controllable load; Data center; Holistic demand response; Tie-line power control; ENERGY; INTEGRATION; MANAGEMENT; TRACKING; SYSTEM; POINT;
D O I
10.1016/j.apenergy.2018.09.093
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the rapid development of cloud computing, artificial intelligence technologies and big data applications, data centers have become widely deployed. High density IT equipment in data centers consumes a lot of electrical power, and makes data center a hungry monster of energy consumption. To solve this problem, renewable energy is increasingly integrated into data center power provisioning systems. Compared to the traditional power supply methods, renewable energy has its unique characteristics, such as intermittency and randomness. When renewable energy supplies power to the data center industrial park, this kind of power supply not only has negative effects on the normal operation of precision equipment, such as CPU/GPU chips and hard disk, in data center, but it would also impact the stability of the utility power grids operation. To solve this problem, this paper presents a novel tie-line power fluctuation smoothing algorithm with consideration of data center's holistic demand response. The contributions of this paper are: (1) overcoming the limitations of treating IT load as uncontrollable workload in the traditional demand response research, we design a data center resource scheduling model to realize IT load demand response controllability; (2) two novel mechanisms are proposed: (i) the server cluster workload scheduling method with time shift mechanism, and (ii) the data center UPS (Uninterruptible Power Supply) energy storage dynamic response mechanism. (3) Combining these two mechanisms as holistic demand response of data center, we present a tie-line power fluctuation smoothing algorithm to improve power supply reliability, which is beneficial to both the high density and precision IT equipment in the data center and the utility power grid. In the experiments, the results show that the new algorithm can effectively regulate the tie-line power fluctuations under different server cluster utilization ranges and scenarios of large-scale penetration of distributed renewable energy scenarios. The new algorithm is hence able to contribute beneficially to the reliability and stability of intelligent industrial park micro-grid and utility power grids.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 42 条
[1]   Reliability and economic assessment of a microgrid power system with the integration of renewable energy resources [J].
Adefarati, T. ;
Bansal, R. C. .
APPLIED ENERGY, 2017, 206 :911-933
[2]  
Aksanli B., 2012, ACM SIGOPS Operating Systems Review, V45, P53, DOI DOI 10.1145/2094091.2094105
[3]  
Amini M.H., 2013, IEEE PES General Meeting 2013, Vancouver, 21-25 July 2013, P1
[4]  
[Anonymous], 2006, WIND ENG
[5]  
Arlitt M, 2012, INTSOC CONF THERMAL, P552, DOI 10.1109/ITHERM.2012.6231479
[6]   Improving energy efficiency of dedicated cooling system and its contribution towards meeting an energy-optimized data center [J].
Cho, Jinkyun ;
Kim, Yundeok .
APPLIED ENERGY, 2016, 165 :967-982
[7]  
Christy Sujatha D., 2011, Proceedings of the 2011 IEEE 3rd International Conference on Cloud Computing Technology and Science (CloudCom 2011), P646, DOI 10.1109/CloudCom.2011.100
[8]  
Chuangang Ren, 2012, 2012 IEEE 20th International Symposium on Modelling, Analysis & Simulation of Computer and Telecommunication Systems (MASCOTS), P391, DOI 10.1109/MASCOTS.2012.51
[9]   Eco-Aware Online Power Management and Load Scheduling for Green Cloud Datacenters [J].
Deng, Xiang ;
Wu, Di ;
Shen, Junfeng ;
He, Jian .
IEEE SYSTEMS JOURNAL, 2016, 10 (01) :78-87