The use of recombination chambers at radiation therapy facilities

被引:12
作者
Zielczynski, Mieczyslaw [2 ]
Golnik, Natalia [1 ]
Gryzinski, Michal A. [2 ]
Tulik, Piotr [1 ,2 ]
机构
[1] Warsaw Univ Technol, Inst Metrol & Biomed Engn, PL-02525 Warsaw, Poland
[2] Inst Atom Energy, PL-05400 Otwock, Poland
关键词
Dosimetry; Radiation therapy; Radiation quality; Recombination chamber; DOSIMETRY; QUALITY; INDEX;
D O I
10.1016/j.radmeas.2010.06.027
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The paper presents an overview of the applications of recombination chambers for dosimetric measurements at radiotherapy facilities. The chambers were used at electron, proton and heavy ion accelerators, in the beam and in the vicinity of the accelerators at very different dose rates. The examples of measurements discussed in the paper include: the determination of the absorbed dose and radiation quality parameters of a 170 MeV proton beam and BNCT (boron neutron capture therapy) beam, neutron dose measurements at a phantom surface outside the beam of a 15 MV electron medical accelerator, determination of ambient dose equivalent, H* (10) outside the irradiated phantom in the proton therapy treatment room at JINR (Dubna, Russia), and at working places outside the shielding of the heavy ion therapy facility at GSI (Darmstadt, Germany). (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1472 / 1475
页数:4
相关论文
共 10 条
[1]  
GOLNIK N, 1995, RADIAT PROT DOSIM, V61, P125
[2]   Recombination index of radiation quality of medical high energy neutron beams [J].
Golnik, N ;
Cherevatenko, EP ;
Serov, AY ;
Shvidkij, SV ;
Sychev, BS ;
Zielczynski, M .
RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) :215-218
[3]  
Golnik N., 1996, IAE20A
[4]  
GRYZINSKI MA, 2009, R16200978 JINR
[5]   Investigations of recombination chambers for BNCT beam dosimetry [J].
Tulik, P. ;
Golnik, N. ;
Zielczynski, M. .
RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) :648-651
[6]   A comparison of different recombination methods in mixed radiation fields at high energy accelerators [J].
Zielczyniski, M. ;
Golnik, N. ;
Gryzinski, M. A. .
RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) :248-252
[7]   A new approach to the dosimetry of mixed radiation using a recombination chamber [J].
Zielczynski, M .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :267-271
[8]  
ZIELCZYNSKI M, 1994, RADIAT PROT DOSIM, V52, P419
[9]  
ZIELCZYNSKI M, 1994, P INT S MEAS ASS DOS, P383
[10]  
ZIELCZYNSKI M, 2000, IAE MONOGRAFIES SWIE, V3