Comparison of normal and weather corrected performance ratio of photovoltaic solar plants in hot and cold climates

被引:17
作者
Gopi, Ajith [1 ,2 ,4 ]
Sudhakar, K. [3 ,4 ,5 ]
Keng, Ngui Wai [1 ]
Krishnan, Ananthu R. [6 ]
机构
[1] Univ Malaysia Pahang, Coll Engn, Kuantan 26300, Pahang, Malaysia
[2] Agcy New & Renewable Energy Res & Technol ANERT, Thiruvananthapuram, Kerala, India
[3] Univ Malaysia Pahang, Fac Mech & Automot Engn Technol, Pekan 26600, Malaysia
[4] Univ Malaysia Pahang, Ctr Automot Engn, Pekan 26600, Pahang, Malaysia
[5] Maulana Azad Natl Inst Technol, Energy Ctr, Bhopal, India
[6] Inst Elect & Elect Engineers, Kerala Sect, Thiruvananthapuram 695001, Kerala, India
关键词
PV power plants; Performance ratio; Weather corrected performance ratio; Tropical regions; Solar radiation resource assessment; PV PLANT; TECHNOLOGIES; INSTALLATION; SYSTEMS;
D O I
10.1016/j.esd.2021.09.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Performance Ratio (PR) is one of the best performance metrics used to assess solar power plant performance. PR is also used for commercial acceptance of an installed PV power plants. If the PR is tested in different climatic conditions or seasons, there are bias errors, affecting the contractual acceptance testing. PR is often corrected to the Standard Test Conditions (STC), resulting in higher PR since modules usually operate at higher temperatures. This research work utilizes NREL's advanced methodology to determine weather corrected PR of PV power plants in six different geographical locations and climatic regions. The Solar PV plant performance is simulated to get the normal PR as per IEC 61724-1:2017. Percentage variation of Weather corrected PR with Normal PR is determined for all these six geographical regions and compared. The weather corrected PR of Montana (with the lowest annual average temperature of 1.58 degrees C.) PV power plant has a maximum variation of 7.64% from the normal PR during the summer and -8.61% variation in December during the winter. The weather corrected PR of Kuzhalmannam (with the highest annual average temperature of 27.28 degrees C) PV power plant has a maximum variation of only 1.16% from the normal PR during summer and a variation of -0.91% in July during the rainy season. It is concluded that the metric of weather-corrected PR gains paramount importance for colder areas, whereas it has minimal influence for tropical regions. (c) 2021 International Energy Initiative. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 44 条
  • [1] Electricity production from large scale PV plants: Benchmarking the potential of Morocco against California, US
    Alami Merrouni, Ahmed
    Amrani, Abdel-illah
    Mezrhab, Ahmed
    [J]. INTERNATIONAL CONFERENCE ON TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY, TMREES17, 2017, 119 : 346 - 355
  • [2] Ananthakrishnan R M. R. S, 1988, ONSET S W MONSOON KE
  • [3] Andre Mermoud B. W, 2020, PVSYST 7 USER MANUAL
  • [4] [Anonymous], 2020, MIN NEW REN EN
  • [5] [Anonymous], 2004, PHOTOVOLTAIC ARRAY P, DOI DOI 10.2172/919131
  • [6] [Anonymous], 2017, 6172412017 IEC
  • [7] [Anonymous], 2013, NRELTP520057991
  • [8] Performance analysis and investigation of a grid-connected photovoltaic installation in Morocco
    Attari, Kamal
    Elyaakoubi, Ali
    Asselman, Adel
    [J]. ENERGY REPORTS, 2016, 2 : 261 - 266
  • [9] Bahar H., 2020, Solar PV Tracking Report
  • [10] Berlin P, 2019, EVALUATION UNDERPERF