Optimization of vortex-assisted ionic liquid dispersive liquid-liquid microextraction by experimental design prior to hydride generation atomic absorption spectrometry for determination of selenium species in food, beverage and water samples

被引:20
作者
Altunay, Nail [1 ]
Elik, Adil [2 ]
Katin, Konstantin [3 ]
机构
[1] Sivas Cumhuriyet Univ, Fac Sci, Dept Biochem, TR-58140 Sivas, Turkey
[2] Sivas Cumhuriyet Univ, Fac Sci, Dept Chem, TR-58140 Sivas, Turkey
[3] Natl Res Nucl Univ MEPhI, Inst Nanoengn Elect Spintron & Photon, Kashirskoe Shosse 31, Moscow 115409, Russia
关键词
Selenium; Experimental design; Food analysis; Food composition; Room temperature ionic liquid; Hydride generation atomic absorption spectrometry; DEEP EUTECTIC SOLVENT; INORGANIC SELENIUM; SPECTROPHOTOMETRIC DETERMINATION; SPECIATION; EXTRACTION; PRECONCENTRATION; PLASMA;
D O I
10.1016/j.jfca.2021.103871
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
We applied novel vortex-assisted ionic liquid dispersive liquid-liquid microextraction (VA-IL-DLLME) method to preconcentration and extraction of Se(IV) ions from water, beverage and food samples. The method was optimized using central composite design combined with the response surface analysis. After extraction, inorganic selenium species (total Se, Se(IV) and Se(VI)) were determined by hydride generation atomic absorption spectrometry. 1-n-Octyl-3-methylimidazolium bis(trifluoromethane)-sulfonamide [C8mim NTf2] and tetrahydrofuran were used as the extraction and dispersive solvents, respectively. Applied vortex assisted the extractant dispersion and accelerated the mass transfer process. Obtained optimum conditions for microextraction procedure are as follows: mass of [C8mim NTf2], pH, extraction time and THF volume should be equal to 85 mg, 6.8, 15 min and 730 mu L, respectively. Under these conditions, we observed linear range, limit of detection and enrichment factor equal to 5-500ng L-1, 1.5 ng L-1 and 120, respectively. We also fount linear regression coefficients in the dependence between Absorbance and Se(IV) concentration: Absorbance = 0.0652 C-Se(IV) + 0.0185. We added 200 mu g kg(-1) of Se(IV) to selected food samples and 100 ng L-1 of Se(IV) to selected waters and beverages. Relative standard deviations and recovery values were within the ranges of 2.4-3.5 % and 92.7 divided by 103.4 %, respectively. The optimized VA-IL-DLLME method reported here provides high extraction efficiency, fast extraction and lower detection limit without a heating step than alternative microextraction methods. This method also requires environmental solvents for determination and preconcentration of trace Se species in the selected samples. In addition, the reported VA-IL-DLLME procedure is the first method which use [C8mim NTf2] as extraction solvent for the preconcentration and separation of Se(IV) ions.
引用
收藏
页数:8
相关论文
共 38 条
[1]   A newly synthesized graft copolymer for magnetic solid phase microextraction of total selenium and its electrothermal atomic absorption spectrometric determination in food and water samples [J].
Acikkapi, Ayse Nihan ;
Tuzen, Mustafa ;
Hazer, Baki .
FOOD CHEMISTRY, 2019, 284 :1-7
[2]   Effects of selenite and selenate application on distribution and transformation of selenium fractions in soil and its bioavailability for wheat (Triticum aestivum L.) [J].
Ali, Fayaz ;
Peng, Qin ;
Wang, Dan ;
Cui, Zewei ;
Huang, Jie ;
Fu, Dongdong ;
Liang, Dongli .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (09) :8315-8325
[3]   Alcohol-DES based vortex assisted homogenous liquid-liquid microextraction approach for the determination of total selenium in food samples by hydride generation AAS: Insights from theoretical and experimental studies [J].
Altunay, Nail ;
Elik, Adil ;
Kaya, Savas .
TALANTA, 2020, 215
[4]   Vortex assisted-ionic liquid dispersive liquid-liquid microextraction and spectrophotometric determination of quercetin in tea, honey, fruit juice and wine samples after optimization based on response surface methodology [J].
Altunay, Nail ;
Bingol, Deniz ;
Elik, Adil ;
Gurkan, Ramazan .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 221
[5]   Determination of sub-ng g-1 levels of total inorganic arsenic and selenium in foods by hydride-generation atomic absorption spectrometry after pre-concentration [J].
Altunay, Nail ;
Gurkan, Ramazan .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2017, 34 (03) :390-403
[6]  
Altunay N, 2016, ANAL METHODS-UK, V8, P8208, DOI [10.1039/C6AY02638A, 10.1039/c6ay02638a]
[7]   Separation/preconcentration of ultra-trace levels of inorganic Sb and Se from different sample matrices by charge transfer sensitized ion-pairing using ultrasonic-assisted cloud point extraction prior to their speciation and determination by hydride generation AAS [J].
Altunay, Nail ;
Gurkan, Ramazan .
TALANTA, 2016, 159 :344-355
[8]  
[Anonymous], 1996, Trace Elements in Human Nutrition and Health
[9]   A simple and sensitive vortex-assisted ionic liquid-dispersive microextraction and spectrophotometric determination of selenium in food samples [J].
Bagda, Esra ;
Tuezen, Mustafa .
FOOD CHEMISTRY, 2017, 232 :98-104
[10]   Preparation and antioxidant properties of selenium nanoparticles-loaded chitosan microspheres [J].
Bai, Kaikai ;
Hong, Bihong ;
He, Jianlin ;
Hong, Zhuan ;
Tan, Ran .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 :4527-4539