Feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory

被引:46
作者
Wang, Haoyu [2 ]
Miao, Yanwei [3 ]
Zhou, Kun [2 ]
Yu, Yanming [2 ]
Bao, Shanglian [2 ]
He, Qiang [4 ]
Dai, Yongming
Xuan, Stephanie Y.
Tarabishy, Bisher [1 ]
Ye, Yongquan [1 ,5 ]
Hu, Jiani [1 ]
机构
[1] Wayne State Univ, Dept Radiol, Detroit, MI 48201 USA
[2] Peking Univ, Beijing City Key Lab Med Phys & Engn, Beijing 100871, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Dalian 116011, Liaoning, Peoples R China
[4] Siemens Mindit Magnet Resonance Ltd Co, Shenzhen 518057, Guangdong, Peoples R China
[5] MR Collaborat NE Asia, Siemens Healthcare China, Shanghai 201318, Peoples R China
关键词
compressed sensing theory; temporal resolution; reference image; RICS; breast DCE-MRI; CONTRAST-ENHANCED MRI; BACK-PROJECTION HYPR; K-T FOCUSS; SIGNAL RECOVERY; PERFUSION MRI; BRAIN-TUMORS; DYNAMIC MRI; RECONSTRUCTION; ANGIOGENESIS; BARRIER;
D O I
10.1118/1.3483094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory. Methods: Two experiments were designed to investigate the feasibility of using reference image based compressed sensing (RICS) technique in DCE-MRI of the breast. The first experiment examined the capability of RICS to faithfully reconstruct uptake curves using undersampled data sets extracted from fully sampled clinical breast DCE-MRI data. An average approach and an approach using motion estimation and motion compensation (ME/MC) were implemented to obtain reference images and to evaluate their efficacy in reducing motion related effects. The second experiment, an in vitro phantom study, tested the feasibility of RICS for improving temporal resolution without degrading the spatial resolution. Results: For the uptake-curve reconstruction experiment, there was a high correlation between uptake curves reconstructed from fully sampled data by Fourier transform and from undersampled data by RICS, indicating high similarity between them. The mean Pearson correlation coefficients for RICS with the ME/MC approach and RICS with the average approach were 0.977 +/- 0.023 and 0.953 +/- 0.031, respectively. The comparisons of final reconstruction results between RICS with the average approach and RICS with the ME/MC approach suggested that the latter was superior to the former in reducing motion related effects. For the in vitro experiment, compared to the fully sampled method, RICS improved the temporal resolution by an acceleration factor of 10 without degrading the spatial resolution. Conclusions: The preliminary study demonstrates the feasibility of RICS for faithfully reconstructing uptake curves and improving temporal resolution of breast DCE-MRI without degrading the spatial resolution. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483094]
引用
收藏
页码:4971 / 4981
页数:11
相关论文
共 51 条
[1]   Temporally constrained reconstruction of dynamic cardiac perfusion MRI [J].
Adluru, Ganesh ;
Awate, Suyash P. ;
Tasdizen, Tolga ;
Whitaker, Ross T. ;
DiBella, Edward V. R. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1027-1036
[2]   New technologies and directed agents for applications of cancer imaging [J].
Atri, Mostafa .
JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (20) :3299-3308
[3]   MRI of tumor angiogenesis [J].
Barrett, Tristan ;
Brechbiel, Martin ;
Bernardo, Marcelino ;
Choyke, Peter L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :235-249
[4]   Dynamic contrast-enhanced MRI measurements of passive permeability through blood retinal barrier in diabetic rats [J].
Berkowitz, BA ;
Roberts, R ;
Luan, HM ;
Peysakhov, J ;
Mao, XZ ;
Thomas, KA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (07) :2391-2398
[5]  
BILGIN A, 2008, ISMRM 16 SCI M UNPUB
[6]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[7]   Near-optimal signal recovery from random projections: Universal encoding strategies? [J].
Candes, Emmanuel J. ;
Tao, Terence .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (12) :5406-5425
[8]   Stable signal recovery from incomplete and inaccurate measurements [J].
Candes, Emmanuel J. ;
Romberg, Justin K. ;
Tao, Terence .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 2006, 59 (08) :1207-1223
[9]   Angiogenesis in cancer and other diseases [J].
Carmeliet, P ;
Jain, RK .
NATURE, 2000, 407 (6801) :249-257
[10]   Temporal Stability of Adaptive 3D Radial MRI Using Multidimensional Golden Means [J].
Chan, Rachel W. ;
Ramsay, Elizabeth A. ;
Cunningham, Charles H. ;
Plewes, Donald B. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) :354-363