Hepatic MR imaging: comparison of 2D and 3D gradient echo techniques

被引:31
作者
Kim, MJ [1 ]
Mitchell, DG [1 ]
Ito, K [1 ]
Kim, PN [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Philadelphia, PA 19107 USA
来源
ABDOMINAL IMAGING | 2001年 / 26卷 / 03期
关键词
liver; MR-MR; pulse sequence;
D O I
10.1007/s002610000177
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To compare fat-suppressed three-dimensional gradient echo (3D-GRE) and two-dimensional gradient echo (2D-GRE) techniques for hepatic magnetic resonance imaging. Methods: For 107 patients with suspected focal hepatic lesions, unenhanced 2D-GRE multislice in-phase and opposed-phase images and 3D-GRE images were obtained. Two radiologists independently and in random order reviewed the images. Quantitative analysis compared contrast-to-noise ratio (C/N) of liver masses and of the liver to spleen and signal-to-noise ratio (S/N) of the liver. Subjective grading of lesion conspicuity, confidence for lesion detection, artifacts, and overall image quality were also evaluated. Results: Conspicuity and confidence for focal lesions was statistically significantly higher on 3D-GRE than on 2D-GRE images, Liver-to-spleen C/N was higher on 3D-GRE images than on in-phase and opposed-phase 2D-GRE images (p < 0.01). Liver S/N was higher on in-phase 2D-GRE images than on 3D-GRE and opposed-phase 2D-GRE images (p < 0.001). Lesion-to-liver C/N was higher on 3D-GRE images than on 2D-GRE images for nonsolid lesions (p < 0.05), but there was no significant difference for solid lesions. Motion and pulsation artifacts were significantly fewer on 3D-GRE images, but graininess and shading were significantly higher. Overall image quality was not significantly different for the three sequences. Conclusion: Fat-suppressed 3D-GRE sequences can afford comparable or better image quality than 2D-GRE images and may have the potential to detect more focal hepatic lesions.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 18 条
[1]   MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN [J].
BRANTZAWADZKI, M ;
GILLAN, GD ;
NITZ, WR .
RADIOLOGY, 1992, 182 (03) :769-775
[2]   DYNAMIC 3-DIMENSIONAL IMAGING WITH PARTIAL K-SPACE SAMPLING - INITIAL APPLICATION FOR GADOLINIUM-ENHANCED RATE CHARACTERIZATION OF BREAST-LESIONS [J].
CHENEVERT, TL ;
HELVIE, MA ;
AISEN, AM ;
FRANCIS, IR ;
ADLER, DD ;
ROUBIDOUX, MA ;
LONDY, FJ .
RADIOLOGY, 1995, 196 (01) :135-142
[3]   SHORT TI INVERSION-RECOVERY IMAGING OF THE LIVER - PULSE-SEQUENCE OPTIMIZATION AND COMPARISON WITH SPIN-ECHO IMAGING [J].
DOUSSET, M ;
WEISSLEDER, R ;
HENDRICK, RE ;
STARK, DD ;
FRETZ, CJ ;
ELIZONDO, G ;
HAHN, PF ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1989, 171 (02) :327-333
[4]   A CHEMICAL-SHIFT SELECTIVE INVERSION RECOVERY SEQUENCE FOR FAT-SUPPRESSED MRI - THEORY AND EXPERIMENTAL VALIDATION [J].
KALDOUDI, E ;
WILLIAMS, SCR ;
BARKER, GJ ;
TOFTS, PS .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :341-355
[5]   FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING OF THE LIVER - PULSE SEQUENCE OPTIMIZATION AND COMPARISON WITH SPIN-ECHO MR IMAGING [J].
LOW, RN ;
FRANCIS, IR ;
HERFKENS, RJ ;
JEFFREY, RB ;
GLAZER, GM ;
FOO, TKF ;
SHIMAKAWA, A ;
PELC, NJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :501-509
[6]   LIVER AND PANCREAS - IMPROVED SPIN-ECHO T1 CONTRAST BY SHORTER ECHO TIME AND FAT SUPPRESSION AT 1.5-T [J].
MITCHELL, DG ;
VINITSKI, S ;
SAPONARO, S ;
TASCIYAN, T ;
BURK, DL ;
RIFKIN, MD .
RADIOLOGY, 1991, 178 (01) :67-71
[7]   TREATMENT OF HEPATOCELLULAR-CARCINOMA BY CHEMOEMBOLIZATION - EVALUATION WITH 3DFT MR IMAGING [J].
MURAKAMI, T ;
NAKAMURA, H ;
TSUDA, K ;
NAKANISHI, K ;
HORI, S ;
TOMODA, K ;
MITANI, T ;
KOZUKA, T ;
MONDEN, M ;
WAKASA, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) :295-299
[8]   3DFT-FISP MRI WITH GADOPENTETATE DIMEGLUMINE IN DIFFERENTIAL-DIAGNOSIS OF SMALL LIVER-TUMORS [J].
NAKAMURA, H ;
MURAKAMI, T ;
ISHIDA, T ;
TSUDA, K ;
HASHIMOTO, T ;
NAKANISHI, K ;
MITANI, T ;
TOMODA, K ;
HORI, S ;
KOZUKA, T .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (01) :49-54
[9]   Half-Fourier, three-dimensional technique for dynamic contrast-enhanced MR imaging of both breasts and axillae: Initial characterization of breast lesions [J].
Perman, WH ;
Heiberg, EV ;
Herrmann, VM .
RADIOLOGY, 1996, 200 (01) :263-269
[10]   A HALF-FOURIER GRADIENT-ECHO TECHNIQUE FOR DYNAMIC MR-IMAGING [J].
PERMAN, WH ;
ELGHAZZAWY, O ;
GADO, MH ;
LARSON, KB ;
PERLMUTTER, JS .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :357-366