METHODS COMPARISON: ASSESSING AGREEMENT OF PHYSIOLOGICAL PARAMETERS OBTAINED FROM EXERCISE ON TWO DIFFERENT CYCLE ERGOMETERS

被引:1
作者
Siedlik, Jake A. [1 ]
Harrison, Grant [2 ]
Brigman, Robert [1 ]
Graham, Zachary A. [1 ]
Weir, Joseph P. [1 ]
Gallagher, Philip M. [1 ]
Vardiman, John P. [1 ]
机构
[1] Univ Kansas, Dept Hlth Sport & Exercise Sci, Lawrence, KS 66045 USA
[2] Univ Wisconsin, Dept Exercise & Sport Sci, La Crosse, WI 54601 USA
关键词
Bland-Altman; cycling; test; HR; (V) over doto(2); HEART-RATE-VARIABILITY; PERFORMANCE; VALIDITY; TESTS; POWER; RELIABILITY; SRM;
D O I
10.1097/JSC.0000000000000205
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Siedlik, JA, Harrison, G, Brigman, R, Graham, ZA, Weir, JP, Gallagher, PM, and Vardiman, JP. Methods comparison: Assessing agreement of physiological parameters obtained from exercise on two different cycle ergometers. J Strength Cond Res 29(4): 1139-1145, 2015-The purpose of this study was to determine the agreement of physiological parameters measured during exercise testing on 2 devices at established power outputs (POs). Ten trained male cyclists were recruited. The devices used for comparison were the Lode stationary bicycle ergometer (SBE) (Lode Excalibur) and the PowerTap Pro+ (BPT) (Saris Cycling Group) mobile ergometer. The physiological parameters recorded at established PO (50, 100, 150, 200, 250 W) were heart rate (HR), oxygen consumption ((V) over doto(2)), pulmonary ventilation (V-E), blood lactate, and ratings of perceived exertion (RPE). Subjects were randomized once to the SBE and 3 times to a bicycle equipped with a BPT. After 15 minutes of unloaded pedaling, the trial began with 5 minutes of cycling at 50 W. Intensity increased by 50 W every 5 minutes up to 250 W. Physiological measures were recorded at each PO. Bland-Altman plots were constructed including computation of the ratio of half the range of limits of agreement and the mean of the pairwise means along with bivariate regression calculations for analysis of the linear association between device measurements. Moderate to good agreement was found for HR with agreement improving as PO increased. Comparisons of (V) over doto(2) found agreement increased as the PO increased. V-E, RPE, and lactate did not consistently provide similar measures across trials. The level of agreement between HR and (V) over doto(2) when comparing the SBE and BPT suggests that the PowerTap Pro+ is a sufficient tool for estimating PO and associated physiological parameters in the field.
引用
收藏
页码:1139 / 1145
页数:7
相关论文
共 21 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
ATTAWAY R, 1992, CAN J SPORT SCI, V17, P56
[3]   Comparison Of Wpeak, VO2peak and the ventilation threshold from two different incremental exercise tests:: Relationship to endurance performance [J].
Bentley, DJ ;
McNaughton, LR .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2003, 6 (04) :422-435
[4]   Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM device [J].
Bertucci, W ;
Duc, S ;
Villerius, V ;
Pernin, JN ;
Grappe, F .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (10) :868-873
[5]   An applied research model for the sport sciences [J].
Bishop, David .
SPORTS MEDICINE, 2008, 38 (03) :253-263
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION [J].
BORG, GAV .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) :377-381
[8]   Validity and Reproducibility of the Ergomo®Pro Power Meter Compared With the SRM and Powertap Power Meters [J].
Duc, Sebastien ;
Villerius, Vincent ;
Bertucci, William ;
Grappe, Frederic .
INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2007, 2 (03) :270-281
[9]   The validity of predicting maximal oxygen uptake from perceptually regulated graded exercise tests of different durations [J].
Eston, Roger G. ;
Faulkner, James A. ;
Mason, Elizabeth A. ;
Parfitt, Gaynor .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 97 (05) :535-541
[10]   Accuracy of SRM and power tap power monitoring systems for bicycling [J].
Gardner, AS ;
Stephens, S ;
Martin, DT ;
Lawton, E ;
Lee, H ;
Jenkins, D .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (07) :1252-1258