Wind-induced responses of tall buildings under combined aerodynamic control

被引:30
作者
Zheng, Chaorong [1 ,2 ]
Xie, Yu [2 ]
Khan, Mahram [2 ]
Wu, Yue [1 ,2 ]
Liu, Jing [3 ,4 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[3] Heilongiiang Prov Key Lab Bldg Energy Efficiency, Harbin 150090, Heilongjiang, Peoples R China
[4] Harbin Inst Technol, Sch Architecture, Harbin 150090, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Tall building; Wind-induced response; Combined aerodynamic control; Shape optimization; Air suction; BACKWARD-FACING STEP; BIDIRECTIONAL CONTROL; INDUCED VIBRATION; BOUNDARY-LAYER; FLOW-CONTROL; SUPPRESSION; MITIGATION; SEPARATION; SIMULATION; SUCTION;
D O I
10.1016/j.engstruct.2018.08.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The new trend towards constructing taller buildings makes modern tall buildings be increasingly susceptible to wind excitations. Therefore, a combined aerodynamic control, including the shape optimization of the cross-section (passive aerodynamic control) and air suction (active aerodynamic control), is put forward to achieve a more considerable reduction of the wind-induced responses of a tall building with square cross-section, so as to improve its wind-resistance performance. Firstly, based on the wind excitations acquired by wind tunnel test of four suction controlled tall building models with different cross-sections (consists of the square, corner-recessed square, corner-chamfered square and Y-shaped cross-sections, and are denoted as Models 1-4 respectively), the wind-induced responses of the prototype tall buildings and simplified mass-spring models are calculated using the time history analysis method. Secondly, effects of the suction flux coefficient C-Q, shapes of the cross-sections and wind direction angles theta on the characteristics of the wind-induced responses are analyzed. The results show that the combined aerodynamic control is very effective in reducing the along-wind and across-wind responses at most cases, however, it can sometimes be unfavorable to the torsional responses. Among the four tall buildings, Model 2 has the best performance in the along-wind direction, with a maximum reduction of the extremum tip displacement of 34% caused by the shape optimization, and 29% caused by the air suction and a total of 63% caused by the combined aerodynamic control at a relatively low C-Q (C-Q = 0.0159). However, the regularity is quite different for the across-wind responses; when theta is equal to 0 degrees, the maximum reduction of the extremum tip displacement in the across-wind direction caused by the shape optimization and air suction are 49% for Model 4 and 47% for Model 1 respectively. Finally, a quantitative discussion on the reduction of the wind-induced responses of tall buildings caused by the combined aerodynamic control is conducted, which can provide a valuable reference for further studies or potential engineering applications.
引用
收藏
页码:86 / 100
页数:15
相关论文
共 44 条
[1]  
[Anonymous], ENG STRUCT
[2]  
[Anonymous], 2012, GB 50009-2012
[3]  
[Anonymous], 1999, Wind Struct, DOI [10.12989/was.1999.2.3.201, DOI 10.12989/WAS.1999.2.3.201]
[4]  
[Anonymous], ADV STRUCTURAL WIND
[5]  
[Anonymous], WIND EXCITED VIBRATI
[6]  
[Anonymous], 2010, J BUILDING STRUCT
[7]  
[Anonymous], NUMERICAL INVESTIGAT
[8]  
[Anonymous], ENG STRUCT
[9]   Mitigation of wind-induced accelerations using Tuned Liquid Column Dampers: Experimental and numerical studies [J].
Cammelli, Stefano ;
Li, Yin Fai ;
Mijorski, Sergey .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 155 :174-181
[10]   Flow Control of an Airfoil via Injection and Suction [J].
Chng, T. L. ;
Rachman, A. ;
Tsai, H. M. ;
Zha, Ge-Cheng .
JOURNAL OF AIRCRAFT, 2009, 46 (01) :291-300