Rapid and Sensitive Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Label-Free Manner Using Micromechanical Sensors

被引:4
作者
Aloraini, Dalal A. [1 ]
Almuqrin, Aljawhara H. [1 ]
Alanazi, Amal [2 ]
Ain, Qura Tul [2 ]
Alodhayb, Abdullah N. [2 ,3 ,4 ]
机构
[1] Princess Nourah bint Abdulrahman Univ, Coll Sci, Dept Phys, Riyadh 11671, Saudi Arabia
[2] King Saud Univ, King Abdullah Inst Nanotechnol, Riyadh 11451, Saudi Arabia
[3] King Saud Univ, Coll Sci, Dept Phys & Astron, Res Chair Tribol Surface & Interface Sci, Riyadh 11451, Saudi Arabia
[4] King Saud Univ, Coll Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
关键词
microcantilever sensor; DNA hybridization; SARS-CoV-2; detection; dynamic mode; DNA;
D O I
10.3390/s21134439
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coronavirus (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has been identified as a deadly pandemic. The genomic analysis of SARS-CoV-2 is performed using a reverse transcription-polymerase chain reaction (RT-PCR) technique for identifying viral ribonucleic acid (RNA) in infected patients. However, the RT-PCR diagnostic technique is manually laborious and expensive; therefore, it is not readily accessible in every laboratory. Methodological simplification is crucial to combat the ongoing pandemic by introducing quick, efficient, and affordable diagnostic methods. Here, we report how microcantilever sensors offer promising opportunities for rapid COVID-19 detection. Our first attempt was to capture the single-stranded complementary DNA of SARS-CoV-2 through DNA hybridization. Therefore, the microcantilever surface was immobilized with an oligonucleotide probe and detected using complementary target DNA hybridization by a shift in microcantilever resonance frequency. Our results show that microcantilever sensors can discriminate between complementary and noncomplementary target DNA on a micro to nanoscale. Additionally, the microcantilever sensors' aptitude toward partial complementary DNA determines their potential to identify new variants of coronavirus. Therefore, microcantilever sensing could be a vital tool in the effort to extinguish the spreading COVID-19 pandemic.
引用
收藏
页数:9
相关论文
共 29 条
[1]   Effect of surface patterning using femtosecond laser on micromechanical and structural properties of micromechanical sensors [J].
Al-Gawati, Mahmoud A. ;
Alhazaa, Abdulaziz ;
Albrithen, Hamad ;
Alnofiay, Jamal ;
Alodhayb, Abdullah .
MATERIALS RESEARCH EXPRESS, 2020, 7 (08)
[2]   Towards detecting the human immunodeficiency virus using microcantilever sensors [J].
Alodhayb, Abdullah ;
Brown, Nicole ;
Rahman, S. M. Saydur ;
Harrigan, Richard ;
Beaulieu, L. Y. .
APPLIED PHYSICS LETTERS, 2013, 102 (17)
[3]   Microcantilever-based platforms as biosensing tools [J].
Alvarez, Mar ;
Lechuga, Laura M. .
ANALYST, 2010, 135 (05) :827-836
[4]   Label-Free Biosensors for Laboratory-Based Diagnostics of Infections: Current Achievements and New Trends [J].
Andryukov, Boris G. ;
Besednova, Natalya N. ;
Romashko, Roman V. ;
Zaporozhets, Tatyana S. ;
Efimov, Timofey A. .
BIOSENSORS-BASEL, 2020, 10 (02)
[5]   Multiplexed and Extraction-Free Amplification for Simplified SARSCoV-2 RT-PCR Tests [J].
Byrnes, Samantha A. ;
Gallagher, Ryan ;
Steadman, Amy ;
Bennett, Crissa ;
Rivera, Rafael ;
Ortega, Corrie ;
Motley, S. Timothy ;
Jain, Paras ;
Weigl, Bernhard H. ;
Connelly, John T. .
ANALYTICAL CHEMISTRY, 2021, 93 (09) :4160-4165
[6]   Detection of Hepatitis B Virus (HBV) DNA at femtomolar concentrations using a silica nanoparticle-enhanced microcantilever sensor [J].
Cha, Byung Hak ;
Lee, Sang-Myung ;
Park, Jae Chan ;
Hwang, Kyo Seon ;
Kim, Sang Kyung ;
Lee, Yoon-Sik ;
Ju, Byeong-Kwon ;
Kim, Tae Song .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) :130-135
[7]  
Cheng H, 2020, INFECT DIS, DOI [10.1101/2020.03.18.20034561v1, DOI 10.1101/2020.03.18.20034561]
[8]   The origin, transmission and clinical therapies on coronavirus disease 2019 (COVID-19) outbreak - an update on the status [J].
Guo, Yan-Rong ;
Cao, Qing-Dong ;
Hong, Zhong-Si ;
Tan, Yuan-Yang ;
Chen, Shou-Deng ;
Jin, Hong-Jun ;
Tan, Kai-Sen ;
Wang, De-Yun ;
Yan, Yan .
MILITARY MEDICAL RESEARCH, 2020, 7 (01)
[9]   A CMOS Cantilever-Based Label-Free DNA SoC With Improved Sensitivity for Hepatitis B Virus Detection [J].
Huang, Yu-Jie ;
Huang, Che-Wei ;
Lin, Tsung-Hsien ;
Lin, Chih-Ting ;
Chen, Li-Guang ;
Hsiao, Po-Yun ;
Wu, Bi-Ru ;
Hsueh, Hsiao-Ting ;
Kuo, Bing-Jye ;
Tsai, Hann-Huei ;
Liao, Hsin-Hao ;
Juang, Ying-Zong ;
Wang, Chorng-Kuang ;
Lu, Shey-Shi .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (06) :820-831
[10]   Attogram detection using nanoelectromechanical oscillators [J].
Ilic, B ;
Craighead, HG ;
Krylov, S ;
Senaratne, W ;
Ober, C ;
Neuzil, P .
JOURNAL OF APPLIED PHYSICS, 2004, 95 (07) :3694-3703