Sensitive determination of nanogram levels of diacerein in a pharmaceutical formulation by flow injection chemiluminescence analysis

被引:7
作者
Han-Chun Yao
Xiao-Feng Yang
Hua Li [1 ]
机构
[1] NW Univ Xian, Inst Analyt Sci, Xian 710069, Peoples R China
[2] NW Univ Xian, Dept Chem, Xian 710069, Peoples R China
关键词
flow injection; chemiluminescence; diacerein; pharmaceutical formulation;
D O I
10.1002/jccs.200700136
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple, sensitive and inexpensive flow injection chemiluminescence (FI-CL) method for the determination of diacerein was proposed. It was based on the greatly enhancive effect of diacerein on the CL reaction between luminol and hydrogen peroxide,in alkaline medium. The enhanced CL intensity was linear with the concentration of diacerein over the range 1.0-500 ng/mL with a detection limit (3 sigma) of 0.2 ng/mL. The relative standard deviation was 1.1% (n = 8, 20 ng/mL diacerein) and the sample throughput was about 120 samples h(-1). This simple method has been successfully applied for the determination of diacerein in a pharmaceutical formulation without interference from its potential impurities. The degradation of diacerein was also investigated briefly.
引用
收藏
页码:949 / 956
页数:8
相关论文
共 21 条
[1]   Effects of diacerhein in an accelerated canine model of osteoarthritis [J].
Brandt, KD ;
Smith, G ;
Kang, SY ;
Myers, S ;
OConnor, B ;
Albrecht, M .
OSTEOARTHRITIS AND CARTILAGE, 1997, 5 (06) :438-449
[2]  
CRUZ T, 2003, PCT INT APPL, P26
[3]   INFLUENCE OF RENAL-FUNCTION ON THE PHARMACOKINETICS OF DIACEREIN AFTER A SINGLE ORAL DOSE [J].
DEBORD, P ;
LOUCHAHI, K ;
TOD, M ;
COURNOT, A ;
PERRET, G ;
PETITJEAN, O .
EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 1994, 19 (01) :13-19
[4]   Chemiluminescence as a diagnostic tool. A review [J].
Dodeigne, C ;
Thunus, L ;
Lejeune, R .
TALANTA, 2000, 51 (03) :415-439
[5]   Investigation on the chemiluminescence reaction of luminol-H2O2-S2-/R-SH system [J].
Du, JX ;
Li, YH ;
Lu, JR .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :79-83
[6]   Flow injection chemiluminescence determination of thiamine based on its enhancing effect on the luminol-hydrogen peroxide system [J].
Du, JX ;
Li, YH ;
Lu, JR .
TALANTA, 2002, 57 (04) :661-665
[7]   Sensitive determination of captopril by flow injection analysis with chemiluminescence detection based on the enhancement of the luminol reaction [J].
Economou, A ;
Themelis, DG ;
Theodoridis, G ;
Tzanavaras, PD .
ANALYTICA CHIMICA ACTA, 2002, 463 (02) :249-255
[8]   A validated HPLC stability-indicating method for the determination of diacerhein in bulk drug substance [J].
Giannellini, V ;
Salvatore, F ;
Bartolucci, G ;
Coran, SA ;
Bambagiotti-Alberti, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) :776-780
[9]   Plant tissue-based chemiluminescence flow biosensor for glycolic acid [J].
Li, BX ;
Zhang, ZJ ;
Jin, Y .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1203-1206
[10]   Microheterogeneous systems of micelles and microemulsions as reaction media in chemiluminescent analysis [J].
Lin, JM ;
Yamada, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (02) :99-107