X-RAY DOSE ESTIMATION FROM CATHODE RAY TUBE MONITORS BY MONTE CARLO CALCULATION

被引:0
作者
Khaledi, Navid [1 ]
Arbabi, Azim [2 ]
Dabaghi, Moloud [1 ]
机构
[1] Islamic Azad Univ, Dept Radiat Med, Sci & Res Branch, Tehran, Iran
[2] Shahid Beheshti Med Univ, Imam Hossein Hosp, Dept Med Phys, Tehran, Iran
来源
HEALTH PHYSICS | 2015年 / 108卷 / 04期
关键词
dose equivalent; effective; dosimetry; Monte Carlo; x ray; DISPLAY TERMINALS; RADIATION;
D O I
10.1097/HP.0000000000000221
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Cathode Ray Tube (CRT) monitors are associated with the possible emission of bremsstrahlung radiation produced by electrons striking the monitor screen. Because of the low dose rate, accurate dosimetry is difficult. In this study, the dose equivalent (DE) and effective dose (ED) to an operator working in front of the monitor have been calculated using the Monte Carlo (MC) method by employing the MCNP code. The mean energy of photons reaching the operator was above 17 keV. The phantom ED was 454 mu Sv y(-1) (348 nSv h(-1)), which was reduced to 16 mu Sv y(-1) (12 nSv h(-1)) after adding a conventional leaded glass sheet. The ambient dose equivalent (ADE) and personal dose equivalent (PDE) for the head, neck, and thorax of the phantom were also calculated. The uncertainty of calculated ED, ADE, and PDE ranged from 3.3% to 10.7% and 4.2% to 14.6% without and with the leaded glass, respectively.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 50 条
[41]   Monte Carlo simulation analysis of X-ray density logging shields [J].
Liu, Rui ;
Yu, Huawei ;
Zhu, Qian ;
Yue, Aizhong ;
Wang, Hu ;
Liu, Chaozhuo ;
Zhang, Qianwen ;
Yang, Shu ;
Zhu, Linke ;
Zhang, Xiaolei .
He Jishu/Nuclear Techniques, 2024, 47 (08)
[42]   Monte Carlo simulator of realistic x-ray beam for diagnostic applications [J].
Bontempi, Marco ;
Andreani, Lucia ;
Rossi, Pier Luca ;
Visani, Andrea .
MEDICAL PHYSICS, 2010, 37 (08) :4201-4209
[43]   X-ray spectra by means of Monte Carlo simulations for imaging applications [J].
Tirao, G. ;
Quintana, C. ;
Malano, F. ;
Valente, M. .
X-RAY SPECTROMETRY, 2010, 39 (06) :376-383
[44]   Monte Carlo simulation of gold nanoparticles for X-ray enhancement application [J].
Dheyab, Mohammed Ali ;
Aziz, Azlan Abdul ;
Rahman, Azhar Abdul ;
Ashour, Nabeel Ibrahim ;
Musa, Ahmed Sadeq ;
Braim, Farhank Saber ;
Jameel, Mahmood S. .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2023, 1867 (04)
[45]   X-ray microanalysis of real materials using Monte Carlo simulations [J].
Gauvin, R ;
Lifshin, E .
MICROCHIMICA ACTA, 2004, 145 (1-4) :41-47
[46]   A bone composition model for Monte Carlo x-ray transport simulations [J].
Zhou, Hu ;
Keall, Paul J. ;
Graves, Edward E. .
MEDICAL PHYSICS, 2009, 36 (03) :1008-1018
[47]   Monte Carlo Simulation of an X-Ray Pixel Beam Microirradiation System [J].
Schreiber, E. C. ;
Chang, S. X. .
RADIATION RESEARCH, 2009, 171 (03) :332-341
[48]   Medical X-ray tube [J].
Taubin, M. ;
Yaskolko, A. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 :722-724
[49]   Fast dose calculation in x-ray guided interventions by using deep learning [J].
Villa, Mateo ;
Nasr, Bahaa ;
Benoit, Didier ;
Padoy, Nicolas ;
Visvikis, Dimitris ;
Bert, Julien .
PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (16)
[50]   Calculation of the modulation transfer function for the X-ray imaging detector DIXI using Monte Carlo simulation data [J].
del Risco Norrlid, L ;
Rönnqvist, C ;
Fransson, K ;
Brenner, R ;
Gustafsson, L ;
Edling, F ;
Kullander, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01) :209-217