Performance of the resurfaced hip. Part 2: the influence of prosthesis stem design on remodelling and fracture of the femoral neck

被引:6
作者
Dickinson, A. S. [1 ]
Taylor, A. C. [2 ]
Jeffers, J. R. T. [2 ]
Browne, M. [1 ]
机构
[1] Univ Southampton, Bioengn Res Grp, Southampton SO17 1BJ, Hants, England
[2] Finsbury Dev Ltd, Leatherhead, Surrey, England
关键词
hip resurfacing; finite element analysis; bone remodelling; neck fracture; prosthesis design; FINITE-ELEMENT-ANALYSIS; SURFACE ARTHROPLASTY; LOAD-TRANSFER; FOLLOW-UP; FEMUR; HEAD; PREDICTION; MODELS; BIOMECHANICS; ORIENTATION;
D O I
10.1243/09544119JEIM680
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hip resurfacing is a popular treatment for osteoarthritis in young, active patients. Previous studies have shown that occasional failures - femoral neck fracture and implant loosening, possibly associated with bone adaptation - are affected by prosthesis sizing and positioning, in addition to patient and surgical factors. With the aim of improving tolerance to surgical variation, finite element modelling was used to indicate the effects of prosthesis metaphyseal stem design on bone remodelling and femoral neck fracture, with a range of implant orientations. The analysis suggested that the intact femoral neck strength in trauma could be maintained across a wider range of varus-valgus orientations for short-stemmed and stemless prostheses. Furthermore, the extent of periprosthetic bone remodelling was lower for the short-stemmed implant, with slightly reduced stress shielding and considerably reduced densification around the stem, potentially preventing further progressive proximal stress shielding. The study suggests that a short-stemmed resurfacing head offers improved tolerance to misalignment and remodelling stimulus over traditional designs. While femoral neck fracture and implant loosening are multifactorial, biomechanical factors are of clear importance to the clinical outcome, so this may reduce the risk for patients at the edge of the indications for hip resurfacing, or shorten the surgical learning curve.
引用
收藏
页码:841 / 851
页数:11
相关论文
共 47 条
[1]  
Amstutz H C, 1998, J Orthop Sci, V3, P169, DOI 10.1007/s007760050038
[2]   Fracture of the neck of the femur after surface arthroplasty of the hip [J].
Amstutz, HC ;
Campbell, PA ;
Le Duff, MJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09) :1874-1877
[3]  
AMSTUTZ HC, 1986, CLIN ORTHOP RELAT R, P92
[4]  
APPLEYARD R, 2009, 55 ANN M ORTH RES SO
[5]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[6]   Metal-on-metal surface arthroplasty with a cemented femoral component -: A 7-10 year follow-up study [J].
Beaulé, PE ;
Le Duff, M ;
Campbell, P ;
Dorey, FJ ;
Park, SH ;
Amstutz, HC .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :17-22
[7]   Notching of the femoral neck during resurfacing arthroplasty of the hip -: A vascular study [J].
Beaulé, PE ;
Campbell, PA ;
Hoke, R ;
Dorey, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (01) :35-39
[8]   Orientation of the femoral component in surface arthroplasty of the hip -: A biomechanical and clinical analysis [J].
Beaulé, PE ;
Lee, JL ;
Le Duff, MJ ;
Amstutz, HC ;
Ebramzadeh, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09) :2015-2021
[9]  
Berend ME, 2007, ORTHOPEDICS, V30, P724, DOI 10.3928/01477447-20070901-17
[10]   ANCHORAGE OF THE FEMORAL HEAD PROSTHESIS TO THE SHAFT OF THE FEMUR [J].
CHARNLEY, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1960, 42 (01) :28-30