The reliability and validity of the 30-seconds sit-to-stand test and its capacity for assessment of the functional status of hemodialysis patients

被引:13
作者
Figueiredo, Pedro Henrique Scheidt [1 ,2 ]
Veloso, Larissa Raphaela de Souza [1 ]
Lima, Marcia Maria Oliveira [1 ]
Vieira, Carlos Filipe Delmondes [2 ]
Alves, Frederico Lopes [3 ,4 ]
Lacerda, Ana Cristina Rodrigues [1 ,2 ]
Lima, Vanessa Pereira [1 ,2 ]
Rodrigues, Vanessa Gomes Brandao [2 ,3 ,4 ]
Maciel, Emilio Henrique Barroso [3 ,4 ]
Costa, Henrique Silveira [1 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri, Phys Therapy Sch, Diamantina, MG, Brazil
[2] Univ Fed Vales Jequitinhonha & Mucuri, Programa Posgrad Reabilitacao & Desempenho Func, Diamantina, MG, Brazil
[3] Santa Casa Caridade Diamantina Hosp, Hemodialysis Unit, Diamantina, MG, Brazil
[4] Univ Fed Vales Jequitinhonha & Mucuri, Sch Med, Diamantina, MG, Brazil
关键词
Exercise tolerance; Outcome assessment; Validity; Hemodialysis; 6-MINUTE WALK TEST; QUALITY-OF-LIFE; MAINTENANCE HEMODIALYSIS; PHYSICAL-ACTIVITY; REFERENCE VALUES; MUSCLE STRENGTH; PEOPLE; DISEASE; PERFORMANCE; MOBILITY;
D O I
10.1016/j.jbmt.2021.02.020
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate the validity of the 30-seconds sit-to-stand test (STS-30) and its reliability in hemodialysis patients. Methods: Patients receiving hemodialysis treatment three times a week for at least six months were evaluated using STS-30, Incremental Shuttle Walking Test, and health-related quality of life by KDQOL-SF questionnaire. The data obtained from the Incremental Shuttle Walking Test were divided into tertiles, and the STS-30 results were compared among tertiles. The accuracy of the STS-30 to identify low exercise capacity was evaluated. A second STS-30 was performed after 6 to 8- weeks for the reliability analyses using Intraclass Correlation Coefficient (ICC). Minimal detectable change scores were calculated. Results: Sixty-three individuals (66.7% men) aged 48.3 years (95%CI 44.6-51.9) were evaluated. There were significant correlations between STS-30, exercise capacity (r = 0.72), and physical domains of health-related quality of life (0.30 <= r <= 0.51). Tertile 1 of the Incremental Shuttle Walking Test was different from tertiles 2 and 3 for STS-30 [difference of 3.4 repetitions (95%CI 1.5-5.4) and 4.7 repetitions (95%CI 2.8-6.7), respectively]. The value of 12 repetitions was the cut-off points for stratification of individuals with low exercise capacity. The STS-30 had a high test-retest reliability (ICC 0.93) and the minimal detectable change was 2.1 repetitions. Conclusion: The STS-30 is a reliable test, associated with exercise capacity and physical domains of health-related quality of life. Thus, is a valid method for functional evaluation in hemodialysis patients. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 47 条
  • [31] Self-performed Five Times Sit-To-Stand test at home as (pre-)screening tool for frailty in cancer survivors: Reliability and agreement assessment
    Maldegem, Sandra J. M. van Cappellen-van
    Hoedjes, Meeke
    Seidell, Jacob C.
    van de Poll-Franse, Lonneke, V
    Buffart, Laurien M.
    Mols, Floortje
    Beijer, Sandra
    JOURNAL OF CLINICAL NURSING, 2023, 32 (7-8) : 1370 - 1380
  • [32] One minute sit-to-stand test is an alternative to 6MWT to measure functional exercise performance in COPD patients
    Reychler, Gregory
    Boucard, Eliott
    Peran, Loic
    Pichon, Romain
    Le Ber-Moy, Catherine
    Ouksel, Hakima
    Liistro, Giuseppe
    Chambellan, Arnaud
    Beaumont, Marc
    CLINICAL RESPIRATORY JOURNAL, 2018, 12 (03) : 1247 - 1256
  • [33] Exercise capacity assessed with the one-minute sit-to-stand test (1-min STST) and echocardiographic findings in patients with heart failure with preserved ejection fraction (HFpEF)
    Kronberger, Christina
    Mousavi, Roya Anahita
    Ozturk, Begum
    Dachs, Theresa-Marie
    Rettl, Rene
    Camuz-Ligios, Luciana
    Litschauer, Brigitte
    Badr-Eslam, Roza
    HEART & LUNG, 2022, 55 : 134 - 139
  • [34] Concurrent and discriminant validity and reliability of an Android App to assess time, velocity and power during sit-to-stand test in community-dwelling older adults
    Juan D. Ruiz-Cárdenas
    Alessio Montemurro
    María del Mar Martínez-García
    Juan J. Rodríguez-Juan
    Aging Clinical and Experimental Research, 2023, 35 (8) : 1631 - 1640
  • [35] Concurrent and discriminant validity and reliability of an Android App to assess time, velocity and power during sit-to-stand test in community-dwelling older adults
    Ruiz-Cardenas, Juan D.
    Montemurro, Alessio
    del Mar Martinez-Garcia, Maria
    Rodriguez-Juan, Juan J.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2023, 35 (08) : 1631 - 1640
  • [36] Differences in power and performance during sit-to-stand test and its relationships to functional measures in older adults with and without Parkinson's disease
    Baltasar-Fernandez, Ivan
    Parrino, Rosalia
    Strand, Keri
    Signorile, Joseph F.
    EXPERIMENTAL GERONTOLOGY, 2024, 195
  • [37] Reliability and validity of the Glittre-ADL test to assess the functional status of patients with interstitial lung disease
    Alexandre, Hellen Fontao
    Cani, Katerine Cristhine
    Araujo, Juliana
    Mayer, Anamaria Fleig
    CHRONIC RESPIRATORY DISEASE, 2021, 18
  • [38] Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients
    Schwenk, M.
    Gogulla, S.
    Englert, S.
    Czempik, A.
    Hauer, K.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (11) : 1931 - 1946
  • [39] Physical Activity Capacity Assessment of Patients With Chronic Disease and the 1-Minute Sit to Stand Test: Is There an Interest?
    Allado, Edem
    Poussel, Mathias
    Albuisson, Eliane
    Paysant, Jean
    Temperelli, Margaux
    Hily, Oriane
    Moussu, Anthony
    Benhajji, Noura
    Gauchard, Gerome
    Chenuel, Bruno
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2022, 4
  • [40] One-minute sit-to-stand test to detect gas exchange capacity during exercise stress in patients with idiopathic or progressive pulmonary fibrosis: A randomized, crossover trial
    Miyata, Yoshito
    Tanaka, Akihiko
    Goto, Yuiko
    Ebato, Takaya
    Suganuma, Hiromitsu
    Nojo, Makoto
    Mikuni, Hatsuko
    Uno, Tomoki
    Uchida, Yoshitaka
    Jinno, Megumi
    Ohta, Shin
    Homma, Tetsuya
    Watanabe, Yoshio
    Kusumoto, Sojiro
    Sagara, Hironori
    RESPIRATORY INVESTIGATION, 2025, 63 (03) : 241 - 246