The reliability and validity of the 30-seconds sit-to-stand test and its capacity for assessment of the functional status of hemodialysis patients

被引:13
作者
Figueiredo, Pedro Henrique Scheidt [1 ,2 ]
Veloso, Larissa Raphaela de Souza [1 ]
Lima, Marcia Maria Oliveira [1 ]
Vieira, Carlos Filipe Delmondes [2 ]
Alves, Frederico Lopes [3 ,4 ]
Lacerda, Ana Cristina Rodrigues [1 ,2 ]
Lima, Vanessa Pereira [1 ,2 ]
Rodrigues, Vanessa Gomes Brandao [2 ,3 ,4 ]
Maciel, Emilio Henrique Barroso [3 ,4 ]
Costa, Henrique Silveira [1 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri, Phys Therapy Sch, Diamantina, MG, Brazil
[2] Univ Fed Vales Jequitinhonha & Mucuri, Programa Posgrad Reabilitacao & Desempenho Func, Diamantina, MG, Brazil
[3] Santa Casa Caridade Diamantina Hosp, Hemodialysis Unit, Diamantina, MG, Brazil
[4] Univ Fed Vales Jequitinhonha & Mucuri, Sch Med, Diamantina, MG, Brazil
关键词
Exercise tolerance; Outcome assessment; Validity; Hemodialysis; 6-MINUTE WALK TEST; QUALITY-OF-LIFE; MAINTENANCE HEMODIALYSIS; PHYSICAL-ACTIVITY; REFERENCE VALUES; MUSCLE STRENGTH; PEOPLE; DISEASE; PERFORMANCE; MOBILITY;
D O I
10.1016/j.jbmt.2021.02.020
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate the validity of the 30-seconds sit-to-stand test (STS-30) and its reliability in hemodialysis patients. Methods: Patients receiving hemodialysis treatment three times a week for at least six months were evaluated using STS-30, Incremental Shuttle Walking Test, and health-related quality of life by KDQOL-SF questionnaire. The data obtained from the Incremental Shuttle Walking Test were divided into tertiles, and the STS-30 results were compared among tertiles. The accuracy of the STS-30 to identify low exercise capacity was evaluated. A second STS-30 was performed after 6 to 8- weeks for the reliability analyses using Intraclass Correlation Coefficient (ICC). Minimal detectable change scores were calculated. Results: Sixty-three individuals (66.7% men) aged 48.3 years (95%CI 44.6-51.9) were evaluated. There were significant correlations between STS-30, exercise capacity (r = 0.72), and physical domains of health-related quality of life (0.30 <= r <= 0.51). Tertile 1 of the Incremental Shuttle Walking Test was different from tertiles 2 and 3 for STS-30 [difference of 3.4 repetitions (95%CI 1.5-5.4) and 4.7 repetitions (95%CI 2.8-6.7), respectively]. The value of 12 repetitions was the cut-off points for stratification of individuals with low exercise capacity. The STS-30 had a high test-retest reliability (ICC 0.93) and the minimal detectable change was 2.1 repetitions. Conclusion: The STS-30 is a reliable test, associated with exercise capacity and physical domains of health-related quality of life. Thus, is a valid method for functional evaluation in hemodialysis patients. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 47 条
  • [1] Modified 30-Second Sit-to-Stand Test: Reliability and Validity in Older Adults Unable to Complete Traditional Sit-to-Stand Testing
    McAllister, Linda S.
    Palombaro, Kerstin M.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2020, 43 (03) : 153 - 158
  • [2] Reliability and validity of the five-repetition sit-to-stand test for children with cerebral palsy
    Wang, Tze-Hsuan
    Liao, Hua-Fang
    Peng, Yi-Chun
    CLINICAL REHABILITATION, 2012, 26 (07) : 664 - 671
  • [3] Reliability and validity of sit-to-stand test protocols in patients with coronary artery disease
    Wang, Zheng
    Yan, Jianhua
    Meng, Shu
    Li, Jiajia
    Yu, Yi
    Zhang, Tingting
    Tsang, Raymond C. C.
    El-Ansary, Doa
    Han, Jia
    Jones, Alice Y. M.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [4] Sit-to-stand test in children with bronchiectasis: Does it measure functional exercise capacity?
    Zeren, Melih
    Gurses, Hulya Nilgun
    Kulli, Hilal Denizoglu
    Ucgun, Hikmet
    Cakir, Erkan
    HEART & LUNG, 2020, 49 (06): : 796 - 802
  • [5] The 1-min sit-to-stand test A simple functional capacity test in cystic fibrosis?
    Radtke, Thomas
    Puhan, Milo A.
    Hebestreit, Helge
    Kriemler, Susi
    JOURNAL OF CYSTIC FIBROSIS, 2016, 15 (02) : 223 - 226
  • [6] Test-retest reliability and validity of the timed up and go test and 30-second sit to stand test in patients with pulmonary hypertension
    Kahraman, Buse Ozcan
    Ozsoy, Ismail
    Akdeniz, Bahri
    Ozpelit, Ebru
    Sevinc, Can
    Acar, Serap
    Savci, Sema
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 304 : 159 - 163
  • [7] Assessment of the 4-meter walk test test-retest reliability and concurrent validity and its correlation with the five sit-to-stand test in chronic ambulatory stroke survivors
    Cabanas-Valdes, Rosa
    Garcia-Rueda, Laura
    Salgueiro, Carina
    Perez-Bellmunt, Albert
    Rodriguez-Sanz, Jacobo
    Lopez-de-Cells, Carlos
    GAIT & POSTURE, 2023, 101 : 8 - 13
  • [8] Test-Retest Reliability and Validity of 1-Minute Sit-to-Stand Test in Patients With Chronic Heart Failure
    Tanriverdi, Aylin
    Kahraman, Buse Ozcan
    Ozpelit, Ebru
    Savci, Sema
    HEART LUNG AND CIRCULATION, 2023, 32 (04) : 518 - 524
  • [9] A comparative study of the five-repetition sit-to-stand test and the 30-second sit-to-stand test to assess exercise tolerance in COPD patients
    Zhang, Qin
    Li, Yan-xia
    Li, Xue-lian
    Yin, Yan
    Li, Rui-lan
    Qiao, Xin
    Li, Wei
    Ma, Hai-feng
    Ma, Wen-hui
    Han, Yu-feng
    Zeng, Guang-qiao
    Wang, Qiu-yue
    Kang, Jian
    Hou, Gang
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 2833 - 2839
  • [10] Validity of the 30-Second Sit-to-Stand test as a measure of lower extremity function in persons with multiple sclerosis: Preliminary evidence
    Zheng, Peixuan
    Huynh, Trinh L. T.
    Jones, C. Danielle
    Feasel, Corey D.
    Jeng, Brenda
    Motl, Robert W.
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2023, 71