The analysis of pneumatic atomization of Newtonian and non-Newtonian fluids for different medical nebulizers

被引:6
|
作者
Ochowiak, Marek [1 ]
Matuszak, Magdalena [1 ]
Wlodarczak, Sylwia [1 ]
机构
[1] Poznan Univ Tech, Inst Chem Technol & Engn, Fac Chem Technol, Poznan, Poland
关键词
Atomization; pneumatic nebulizer; shear and extensional viscosity; surface tension; droplet size histogram; mean droplet diameter; VIBRATING-MESH NEBULIZATION; DRY POWDER INHALER; AIR-JET; DRUG-DELIVERY; ULTRASONIC ATOMIZATION; EXTENSIONAL VISCOSITY; PHYSICOCHEMICAL PROPERTIES; PERFORMANCE; INHALATION; SIZE;
D O I
10.1080/03639045.2017.1358274
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Objective: The article contains results of the experimental studies on atomization process of inhaled drugs and aqueous solutions of glycerol with aqueous solutions of glycerol polyacrylamide (Rokrysol WF1) in pneumatic nebulizers. In experiments, the different concentration of aqueous solutions of glycerol polyacrylamide have been tested. In addition, the effect of nebulizer design on atomization process has been determined. The one of the main elements of medical pneumatic nebulizer is nebulizer cup. Significance: The experiment with this scope is new and is very important from the point of view of aerosol therapy. Methods: The results have been obtained by the use of the digital microphotography technique. In order to determine a physicochemical properties of tested liquids, a rheological measurements and measurements of the surface tension were carried out. Results: The differences between characteristics of aerosol for the liquids have been observed. The analysis of the droplets size distributions shows that the different diameters of droplets for Newtonian and non-Newtonian fluids have been formed during atomization in pneumatic nebulizers equipped with different nebulizer cups. The effect of the mouthpiece location on the droplets diameters has been shown. Conclusions: Precise design of nebulizer and nebulizer cups, and also physicochemical properties of atomized liquids are of high importance in order to the effectiveness of drug delivery to patient's respiratory tracts.
引用
收藏
页码:1999 / 2010
页数:12
相关论文
共 50 条
  • [21] CFD Analysis of Taylor Bubble in a Co-Flow Microchannel with Newtonian and Non-Newtonian Liquid
    Sontti, Somasekhara Goud
    Atta, Arnab
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2017, 56 (25) : 7401 - 7412
  • [22] Fractional order based velocity control system for a nanorobot in non-Newtonian fluids
    Muresan, C., I
    Birs, I. R.
    Folea, S.
    Ionescu, C.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2018, 66 (06) : 991 - 997
  • [23] A novel check microvalve designed for non-Newtonian fluids by applying an optimization algorithm
    Dong, Xin
    Liu, Xiaomin
    CHEMICAL ENGINEERING JOURNAL, 2021, 407
  • [24] Marangoni convection of non-Newtonian power law fluids in a shallow rectangular cavity
    Naïmi, M
    Hasnaoui, M
    Platten, JK
    ENGINEERING COMPUTATIONS, 2000, 17 (6-7) : 638 - 668
  • [25] Micromixing of Non-Newtonian Fluids in a Passive Micromixer with an Inner Eccentric Cylindrical Obstacle
    Bayareh, Morteza
    Ghahfarokhi, Narges Jafari
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2024, 43 (09): : 3350 - 3356
  • [26] Stability of non-newtonian fluid flows
    L. A. Spodareva
    Journal of Applied Mechanics and Technical Physics, 2000, 41 (3) : 446 - 451
  • [27] Heat Transfer and Fluid Flow Characteristics for Newtonian and Non-Newtonian Fluids in a Tube-in-Tube Helical Coil Heat Exchanger
    Kushwaha, Naveen
    Kumawat, Tara Chand
    Nigam, Krishna Deo Prasad
    Kumar, Vimal
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (09) : 3972 - 3984
  • [28] The effects of pulsation and retraction on non-Newtonian flows in three-stream injector atomization systems
    Strasser, Wayne
    Battaglia, Francine
    CHEMICAL ENGINEERING JOURNAL, 2017, 309 : 532 - 544
  • [29] Numerical investigation of Newtonian and non-Newtonian multiphase flows using ISPH method
    Zainali, A.
    Tofighi, N.
    Shadloo, M. S.
    Yildiz, M.
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2013, 254 : 99 - 113
  • [30] Newtonian and non-Newtonian spray interaction with a high-speed moving surface
    Dressler, D. M.
    Li, L. K. B.
    Green, S. I.
    Davy, M. H.
    Eadie, D. T.
    ATOMIZATION AND SPRAYS, 2009, 19 (01) : 19 - 39