Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigations

被引:11
|
作者
Duetschler, Alisha [1 ,2 ]
Bauman, Grzegorz [3 ,4 ]
Bieri, Oliver [3 ,4 ]
Cattin, Philippe C. [3 ,5 ]
Ehrbar, Stefanie [6 ,7 ]
Engin-Deniz, Georg [1 ,2 ]
Giger, Alina [3 ,5 ]
Josipovic, Mirjana [8 ]
Jud, Christoph [3 ,5 ]
Krieger, Miriam [1 ,2 ]
Nguyen, Damien [3 ,4 ]
Persson, Gitte F. [8 ,9 ,10 ]
Salomir, Rares [11 ,12 ]
Weber, Damien C. [1 ,6 ,13 ]
Lomax, Antony J. [1 ,2 ]
Zhang, Ye [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Forschungsstr 111, CH-5232 Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Basel, Dept Biomed Engn, Allschwil, Switzerland
[4] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Basel, Switzerland
[5] Univ Basel, Ctr Med Image Anal & Nav, Allschwil, Switzerland
[6] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[7] Univ Zurich, Zurich, Switzerland
[8] Copenhagen Univ Hosp, Dept Oncol, Rigshosp, Copenhagen, Denmark
[9] Copenhagen Univ Hosp, Dept Oncol, Herlev Gentofte Hosp, Herlev, Denmark
[10] Univ Copenhagen, Fac Med Sci, Dept Clin Med, Copenhagen, Denmark
[11] Univ Geneva, Fac Med, Image Guided Intervent Lab 949, Geneva, Switzerland
[12] Univ Hosp Geneva, Radiol Div, Geneva, Switzerland
[13] Univ Bern, Dept Radiat Oncol, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
4D imaging; 4DMRI; 4D numerical phantom; intrafraction motion; proton therapy; RESPIRATORY MOTION; XCAT PHANTOM; PROTON; CT; SIMULATION; THERAPY; MODEL; REGISTRATION; DEFORMATION; FRAMEWORK;
D O I
10.1002/mp.15591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Respiratory motion is one of the major challenges in radiotherapy. In this work, a comprehensive and clinically plausible set of 4D numerical phantoms, together with their corresponding "ground truths," have been developed and validated for 4D radiotherapy applications. Methods The phantoms are based on CTs providing density information and motion from multi-breathing-cycle 4D Magnetic Resonance imagings (MRIs). Deformable image registration (DIR) has been utilized to extract motion fields from 4DMRIs and to establish inter-subject correspondence by registering binary lung masks between Computer Tomography (CT) and MRI. The established correspondence is then used to warp the CT according to the 4DMRI motion. The resulting synthetic 4DCTs are called 4DCT(MRI)s. Validation of the 4DCT(MRI) workflow was conducted by directly comparing conventional 4DCTs to derived synthetic 4D images using the motion of the 4DCTs themselves (referred to as 4DCT(CT)s). Digitally reconstructed radiographs (DRRs) as well as 4D pencil beam scanned (PBS) proton dose calculations were used for validation. Results Based on the CT image appearance of 13 lung cancer patients and deformable motion of five volunteer 4DMRIs, synthetic 4DCT(MRI)s with a total of 871 different breathing cycles have been generated. The 4DCT(MRI)s exhibit an average superior-inferior tumor motion amplitude of 7 +/- 5 mm (min: 0.5 mm, max: 22.7 mm). The relative change of the DRR image intensities of the conventional 4DCTs and the corresponding synthetic 4DCT(CT)s inside the body is smaller than 5% for at least 81% of the pixels for all studied cases. Comparison of 4D dose distributions calculated on 4DCTs and the synthetic 4DCT(CT)s using the same motion achieved similar dose distributions with an average 2%/2 mm gamma pass rate of 90.8% (min: 77.8%, max: 97.2%). Conclusion We developed a series of numerical 4D lung phantoms based on real imaging and motion data, which give realistic representations of both anatomy and motion scenarios and the accessible "ground truth" deformation vector fields of each 4DCT(MRI). The open-source code and motion data allow foreseen users to generate further 4D data by themselves. These numeric 4D phantoms can be used for the development of new 4D treatment strategies, 4D dose calculations, DIR algorithm validations, as well as simulations of motion mitigation and different online image guidance techniques for both proton and photon radiation therapy.
引用
收藏
页码:2890 / 2903
页数:14
相关论文
共 50 条
  • [41] Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study
    Bernatowicz, K.
    Keall, P.
    Mishra, P.
    Knopf, A.
    Lomax, A.
    Kipritidis, J.
    MEDICAL PHYSICS, 2015, 42 (01) : 324 - 334
  • [42] Continuous real time 3D motion reproduction using dynamic MRI and precomputed 4DCT deformation fields
    Dasnoy-Sumell, Damien
    Souris, Kevin
    Van Ooteghem, G.
    Macq, Benoit
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (08): : 236 - 248
  • [43] Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data
    Werner, Rene
    Ehrhardt, Jan
    Schmidt-Richberg, Alexander
    Heiss, Anabell
    Handels, Heinz
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (06) : 595 - 605
  • [44] CT-PET image fusion using the 4D NCAT phantom with the purpose of attenuation correction
    Segars, WP
    Tsui, BMW
    Da Silva, AJ
    Shao, L
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1775 - 1779
  • [45] Generation of Realistic 4D Synthetic CSPAMM Tagged MR Sequences for Benchmarking Cardiac Motion Tracking Algorithms
    Zhou, Yitian
    De Craene, Mathieu
    Somphone, Oudom
    Sermesant, Maxime
    Bernard, Olivier
    SIMULATION AND SYNTHESIS IN MEDICAL IMAGING, SASHIMI 2016, 2016, 9968 : 108 - 117
  • [46] A novel 3D-printed phantom insert for 4D PET/CT imaging and simultaneous integrated boost radiotherapy
    Cervino, Laura
    Soultan, Dima
    Cornell, Mariel
    Yock, Adam
    Pettersson, Niclas
    Song, William Y.
    Aguilera, Joseph
    Advani, Sunil
    Murphy, James
    Hoh, Carl
    James, Claude
    Paravati, Anthony
    Coope, Robin
    Gill, Bradford
    Moiseenko, Vitali
    MEDICAL PHYSICS, 2017, 44 (10) : 5467 - 5474
  • [47] Serial 4DCT/4DPET imaging to predict and monitor response for locally-advanced non-small cell lung cancer chemo-radiotherapy
    Bissonnette, Jean-Pierre
    Yap, Mei Ling
    Clarke, Katy
    Shessel, Andrea
    Higgins, Jane
    Vines, Douglass
    Atenafu, Eshetu G.
    Becker, Nathan
    Leavens, Claudia
    Bezjak, Andrea
    Jaffray, David A.
    Sun, Alexander
    RADIOTHERAPY AND ONCOLOGY, 2018, 126 (02) : 347 - 354
  • [48] 4D motion models over the respiratory cycle for use in lung cancer radiotherapy planning
    McClelland, JR
    Chandler, AG
    Blackall, JM
    Ahmad, S
    Landau, DB
    Hawkes, DJ
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 173 - 183
  • [49] A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy
    McClelland, Jamie R.
    Blackall, Jane M.
    Tarte, Segolene
    Chandler, Adam C.
    Hughes, Simon
    Ahmad, Shahreen
    Landau, David B.
    Hawkes, David J.
    MEDICAL PHYSICS, 2006, 33 (09) : 3348 - 3358
  • [50] An image interpolation approach for acquisition time reduction in navigator-based 4D MRI
    Karani, Neerav
    Zhang, Lin
    Tanner, Christine
    Konukoglu, Ender
    MEDICAL IMAGE ANALYSIS, 2019, 54 : 20 - 29