Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigations

被引:11
|
作者
Duetschler, Alisha [1 ,2 ]
Bauman, Grzegorz [3 ,4 ]
Bieri, Oliver [3 ,4 ]
Cattin, Philippe C. [3 ,5 ]
Ehrbar, Stefanie [6 ,7 ]
Engin-Deniz, Georg [1 ,2 ]
Giger, Alina [3 ,5 ]
Josipovic, Mirjana [8 ]
Jud, Christoph [3 ,5 ]
Krieger, Miriam [1 ,2 ]
Nguyen, Damien [3 ,4 ]
Persson, Gitte F. [8 ,9 ,10 ]
Salomir, Rares [11 ,12 ]
Weber, Damien C. [1 ,6 ,13 ]
Lomax, Antony J. [1 ,2 ]
Zhang, Ye [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Forschungsstr 111, CH-5232 Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Basel, Dept Biomed Engn, Allschwil, Switzerland
[4] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Basel, Switzerland
[5] Univ Basel, Ctr Med Image Anal & Nav, Allschwil, Switzerland
[6] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[7] Univ Zurich, Zurich, Switzerland
[8] Copenhagen Univ Hosp, Dept Oncol, Rigshosp, Copenhagen, Denmark
[9] Copenhagen Univ Hosp, Dept Oncol, Herlev Gentofte Hosp, Herlev, Denmark
[10] Univ Copenhagen, Fac Med Sci, Dept Clin Med, Copenhagen, Denmark
[11] Univ Geneva, Fac Med, Image Guided Intervent Lab 949, Geneva, Switzerland
[12] Univ Hosp Geneva, Radiol Div, Geneva, Switzerland
[13] Univ Bern, Dept Radiat Oncol, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
4D imaging; 4DMRI; 4D numerical phantom; intrafraction motion; proton therapy; RESPIRATORY MOTION; XCAT PHANTOM; PROTON; CT; SIMULATION; THERAPY; MODEL; REGISTRATION; DEFORMATION; FRAMEWORK;
D O I
10.1002/mp.15591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Respiratory motion is one of the major challenges in radiotherapy. In this work, a comprehensive and clinically plausible set of 4D numerical phantoms, together with their corresponding "ground truths," have been developed and validated for 4D radiotherapy applications. Methods The phantoms are based on CTs providing density information and motion from multi-breathing-cycle 4D Magnetic Resonance imagings (MRIs). Deformable image registration (DIR) has been utilized to extract motion fields from 4DMRIs and to establish inter-subject correspondence by registering binary lung masks between Computer Tomography (CT) and MRI. The established correspondence is then used to warp the CT according to the 4DMRI motion. The resulting synthetic 4DCTs are called 4DCT(MRI)s. Validation of the 4DCT(MRI) workflow was conducted by directly comparing conventional 4DCTs to derived synthetic 4D images using the motion of the 4DCTs themselves (referred to as 4DCT(CT)s). Digitally reconstructed radiographs (DRRs) as well as 4D pencil beam scanned (PBS) proton dose calculations were used for validation. Results Based on the CT image appearance of 13 lung cancer patients and deformable motion of five volunteer 4DMRIs, synthetic 4DCT(MRI)s with a total of 871 different breathing cycles have been generated. The 4DCT(MRI)s exhibit an average superior-inferior tumor motion amplitude of 7 +/- 5 mm (min: 0.5 mm, max: 22.7 mm). The relative change of the DRR image intensities of the conventional 4DCTs and the corresponding synthetic 4DCT(CT)s inside the body is smaller than 5% for at least 81% of the pixels for all studied cases. Comparison of 4D dose distributions calculated on 4DCTs and the synthetic 4DCT(CT)s using the same motion achieved similar dose distributions with an average 2%/2 mm gamma pass rate of 90.8% (min: 77.8%, max: 97.2%). Conclusion We developed a series of numerical 4D lung phantoms based on real imaging and motion data, which give realistic representations of both anatomy and motion scenarios and the accessible "ground truth" deformation vector fields of each 4DCT(MRI). The open-source code and motion data allow foreseen users to generate further 4D data by themselves. These numeric 4D phantoms can be used for the development of new 4D treatment strategies, 4D dose calculations, DIR algorithm validations, as well as simulations of motion mitigation and different online image guidance techniques for both proton and photon radiation therapy.
引用
收藏
页码:2890 / 2903
页数:14
相关论文
共 50 条
  • [31] 4DCBCT-based motion modeling and 3D fluoroscopic image generation for lung cancer radiotherapy
    Dhou, Salam
    Hurwitz, Martina
    Mishra, Pankaj
    Berbeco, Ross
    Lewis, John
    MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [32] Evaluation of the Elekta Symmetry™ 4D IGRT system by using a moving lung phantom
    Hun-Joo Shin
    Shin-Wook Kim
    Chul Seung Kay
    Jae-Hyuk Seo
    Gi-Woong Lee
    Ki-Mun Kang
    Hong Seok Jang
    Young-nam Kang
    Journal of the Korean Physical Society, 2015, 67 : 260 - 263
  • [33] Hybrid unsupervised paradigm based deformable image fusion for 4D CT lung image modality
    Iqbal, Muhammad Zafar
    Razzak, Imran
    Qayyum, Abdul
    Nguyen, Thanh Thi
    Tanveer, M.
    Sowmya, Arcot
    INFORMATION FUSION, 2024, 102
  • [34] Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer
    Valdes, Gilmer
    Robinson, Clifford
    Lee, Percy
    Morel, Delphine
    Low, Daniel
    Iwamoto, Keisuke S.
    Lamb, James M.
    MEDICAL DOSIMETRY, 2015, 40 (01) : 64 - 69
  • [35] Accelerating 4D image reconstruction for magnetic resonance-guided radiotherapy
    Lecoeur, Bastien
    Barbone, Marco
    Gough, Jessica
    Oelfke, Uwe
    Luk, Wayne
    Gaydadjiev, Georgi
    Wetscherek, Andreas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [36] A radiobiological analysis of the effect of 3D versus 4D image-based planning in lung cancer radiotherapy
    Roland, Teboh
    Mavroidis, Panayiotis
    Gutierrez, Alonso
    Goytia, Virginia
    Papanikolaou, Niko
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (18) : 5509 - 5523
  • [37] 4D dose-position verification in radiation therapy using the RADPOS system in a deformable lung phantom
    Cherpak, Amanda
    Serban, Monica
    Seuntjens, Jan
    Cygler, Joanna E.
    MEDICAL PHYSICS, 2011, 38 (01) : 179 - 187
  • [38] Simultaneous multi-slice accelerated 4D-MRI for radiotherapy guidance
    Keijnemans, K.
    Borman, P. T. S.
    van Lier, A. L. H. M. W.
    Verhoeff, J. J. C.
    Raaymakers, B. W.
    Fast, M. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (09)
  • [39] The impact of breathing guidance and prospective gating during thoracic 4DCT imaging: an XCAT study utilizing lung cancer patient motion
    Pollock, Sean
    Kipritidis, John
    Lee, Danny
    Bernatowicz, Kinga
    Keall, Paul
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (17) : 6485 - 6501
  • [40] 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
    Li, Yi
    Ma, Jing-lu
    Chen, Xin
    Tang, Feng-wen
    Zhang, Xiao-zhi
    RADIATION ONCOLOGY, 2016, 11