Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigations

被引:11
|
作者
Duetschler, Alisha [1 ,2 ]
Bauman, Grzegorz [3 ,4 ]
Bieri, Oliver [3 ,4 ]
Cattin, Philippe C. [3 ,5 ]
Ehrbar, Stefanie [6 ,7 ]
Engin-Deniz, Georg [1 ,2 ]
Giger, Alina [3 ,5 ]
Josipovic, Mirjana [8 ]
Jud, Christoph [3 ,5 ]
Krieger, Miriam [1 ,2 ]
Nguyen, Damien [3 ,4 ]
Persson, Gitte F. [8 ,9 ,10 ]
Salomir, Rares [11 ,12 ]
Weber, Damien C. [1 ,6 ,13 ]
Lomax, Antony J. [1 ,2 ]
Zhang, Ye [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Forschungsstr 111, CH-5232 Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Basel, Dept Biomed Engn, Allschwil, Switzerland
[4] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Basel, Switzerland
[5] Univ Basel, Ctr Med Image Anal & Nav, Allschwil, Switzerland
[6] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[7] Univ Zurich, Zurich, Switzerland
[8] Copenhagen Univ Hosp, Dept Oncol, Rigshosp, Copenhagen, Denmark
[9] Copenhagen Univ Hosp, Dept Oncol, Herlev Gentofte Hosp, Herlev, Denmark
[10] Univ Copenhagen, Fac Med Sci, Dept Clin Med, Copenhagen, Denmark
[11] Univ Geneva, Fac Med, Image Guided Intervent Lab 949, Geneva, Switzerland
[12] Univ Hosp Geneva, Radiol Div, Geneva, Switzerland
[13] Univ Bern, Dept Radiat Oncol, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
4D imaging; 4DMRI; 4D numerical phantom; intrafraction motion; proton therapy; RESPIRATORY MOTION; XCAT PHANTOM; PROTON; CT; SIMULATION; THERAPY; MODEL; REGISTRATION; DEFORMATION; FRAMEWORK;
D O I
10.1002/mp.15591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Respiratory motion is one of the major challenges in radiotherapy. In this work, a comprehensive and clinically plausible set of 4D numerical phantoms, together with their corresponding "ground truths," have been developed and validated for 4D radiotherapy applications. Methods The phantoms are based on CTs providing density information and motion from multi-breathing-cycle 4D Magnetic Resonance imagings (MRIs). Deformable image registration (DIR) has been utilized to extract motion fields from 4DMRIs and to establish inter-subject correspondence by registering binary lung masks between Computer Tomography (CT) and MRI. The established correspondence is then used to warp the CT according to the 4DMRI motion. The resulting synthetic 4DCTs are called 4DCT(MRI)s. Validation of the 4DCT(MRI) workflow was conducted by directly comparing conventional 4DCTs to derived synthetic 4D images using the motion of the 4DCTs themselves (referred to as 4DCT(CT)s). Digitally reconstructed radiographs (DRRs) as well as 4D pencil beam scanned (PBS) proton dose calculations were used for validation. Results Based on the CT image appearance of 13 lung cancer patients and deformable motion of five volunteer 4DMRIs, synthetic 4DCT(MRI)s with a total of 871 different breathing cycles have been generated. The 4DCT(MRI)s exhibit an average superior-inferior tumor motion amplitude of 7 +/- 5 mm (min: 0.5 mm, max: 22.7 mm). The relative change of the DRR image intensities of the conventional 4DCTs and the corresponding synthetic 4DCT(CT)s inside the body is smaller than 5% for at least 81% of the pixels for all studied cases. Comparison of 4D dose distributions calculated on 4DCTs and the synthetic 4DCT(CT)s using the same motion achieved similar dose distributions with an average 2%/2 mm gamma pass rate of 90.8% (min: 77.8%, max: 97.2%). Conclusion We developed a series of numerical 4D lung phantoms based on real imaging and motion data, which give realistic representations of both anatomy and motion scenarios and the accessible "ground truth" deformation vector fields of each 4DCT(MRI). The open-source code and motion data allow foreseen users to generate further 4D data by themselves. These numeric 4D phantoms can be used for the development of new 4D treatment strategies, 4D dose calculations, DIR algorithm validations, as well as simulations of motion mitigation and different online image guidance techniques for both proton and photon radiation therapy.
引用
收藏
页码:2890 / 2903
页数:14
相关论文
共 50 条
  • [1] Technical note: Towards more realistic 4DCT(MRI) numerical lung phantoms
    Jenny, Timothy
    Duetschler, Alisha
    Giger, Alina
    Pusterla, Orso
    Safai, Sairos
    Weber, Damien C.
    Lomax, Antony J.
    Zhang, Ye
    MEDICAL PHYSICS, 2024, 51 (01) : 579 - 590
  • [2] Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT
    Liu, Gang
    Hu, Fala
    Ding, Xuanfeng
    Li, Xiaoqiang
    Shao, Qihong
    Wang, Yuenan
    Yang, Jing
    Quan, Hong
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [3] Clinical evaluation of 4D MRI in the delineation of gross and internal tumor volumes in comparison with 4DCT
    Zhang, Jingjing
    Srivastava, Shreya
    Wang, Chunyu
    Beckham, Thomas
    Johnson, Christopher
    Dutta, Pinaki
    Shepherd, Annemarie
    Mechalakos, James
    Hunt, Margie
    Wu, Abraham
    Rimner, Andreas
    Li, Guang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 51 - 60
  • [4] 4DCT ventilation function image-based functional lung protection for esophageal cancer radiotherapy
    Zhou, Pixiao
    Wang, Ruihao
    Yu, Hui
    Liao, Zhiwei
    Zhang, Ying
    Huang, Zouqin
    Zhang, Shuxu
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (05) : 445 - 455
  • [5] Commissioning of a 4D MRI phantom for use in MR-guided radiotherapy
    Schneider, Sergej
    Dolde, Kai
    Engler, Johanna
    Hoffmann, Aswin
    Pfaffenberger, Asja
    MEDICAL PHYSICS, 2019, 46 (01) : 25 - 33
  • [6] Image-based retrospective 4D MRI in external beam radiotherapy: A comparative study with a digital phantom
    Paganelli, Chiara
    Kipritidis, John
    Lee, Danny
    Baroni, Guido
    Keall, Paul
    Riboldi, Marco
    MEDICAL PHYSICS, 2018, 45 (07) : 3161 - 3172
  • [7] 4DCT image-based lung motion field extraction and analysis
    Klinder, Tobias
    Lorenz, Cristian
    von Berg, Jens
    Renisch, Steffen
    Blaffert, Thomas
    Ostermann, Joern
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [8] Virtual 4DCT generated from 4DMRI in gated particle therapy: phantom validation and application to lung cancer patients
    Annunziata, S.
    Rabe, M.
    Vai, A.
    Molinelli, S.
    Nakas, A.
    Meschini, G.
    Pella, A.
    Vitolo, V.
    Barcellini, A.
    Imparato, S.
    Ciocca, M.
    Orlandi, E.
    Landry, G.
    Kamp, F.
    Kurz, C.
    Baroni, G.
    Riboldi, M.
    Paganelli, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14)
  • [9] A 4D biomechanical lung phantom for joint segmentation/registration evaluation
    Markel, Daniel
    Levesque, Ives
    Larkin, Joe
    Leger, Pierre
    El Naqa, Issam
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (19) : 7012 - 7030
  • [10] Accuracy and consistency of intensity-based deformable image registration in 4DCT for tumor motion estimation in liver radiotherapy planning
    Tascon-Vidarte, Jose D.
    Stick, Line Bjerregaard
    Josipovic, Mirjana
    Risum, Signe
    Jomier, Julien
    Erleben, Kenny
    Vogelius, Ivan Richter
    Darkner, Sune
    PLOS ONE, 2022, 17 (07):