Damping Perception During Active Ankle and Knee Movement

被引:6
作者
Azocar, Alejandro F. [1 ,2 ,3 ]
Shorter, Amanda L. [3 ,4 ]
Rouse, Elliott J. [1 ,2 ,3 ]
机构
[1] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Robot Inst, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Neurob Lab, Ann Arbor, MI 48109 USA
[4] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
基金
美国国家科学基金会;
关键词
Assistive devices; human factors; perception; psychophysics; damping; HUMAN OPERATOR DYNAMICS; MECHANICAL-PROPERTIES; STANCE PHASE; IMPEDANCE; DISCRIMINATION; SENSE; REHABILITATION; MANIPULANDUM; INFORMATION; STIFFNESS;
D O I
10.1109/TNSRE.2019.2894156
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The mechanical impedance of the leg governs many important aspects of locomotion, including energy storage, transfer, and dissipation between joints. These mechanical properties, including stiffness and damping, have been recently quantified at the ankle joint during walking. However, little is known about the human ability to sense changes in impedance. Here, we investigate the ability to detect small changes in damping coefficients when interacting with a mechanical system coupled to the ankle or knee joint. Using a psychophysical experiment (adaptive, weighted staircase method) and an admittance-controlled dynamometer, we determined the 75% minimum detectable change by tasking subjects to compare the damping values of different virtual spring-mass-damper systems. The Weber fraction for damping coefficient ranged from 12% to 31%, with similar performance across the ankle and knee. Damping perception performance was similar to previous stiffness perception results, suggesting that both the stiffness and damping of the environment are important for the human sensorimotor system and motivating further investigation on the role of damping in biomechanics, motor control, and wearable robotic technologies.
引用
收藏
页码:198 / 206
页数:9
相关论文
共 51 条
[1]   Stable haptic interaction with virtual environments [J].
Adams, RJ ;
Hannaford, B .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1999, 15 (03) :465-474
[2]   Active-impedance control of a lower-limb Assistive exoskeleton [J].
Aguirre-Ollinger, Gabriel ;
Colgate, J. Edward ;
Peshkin, Michael A. ;
Goswami, Ambarish .
2007 IEEE 10TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, VOLS 1 AND 2, 2007, :188-+
[3]   Stiffness Perception During Active Ankle and Knee Movement [J].
Azocar, Alejandro F. ;
Rouse, Elliott J. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (12) :2949-2956
[4]   JOINT PROPRIOCEPTION IN NORMAL, OSTEOARTHRITIC AND REPLACED KNEES [J].
BARRETT, DS ;
COBB, AG ;
BENTLEY, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :53-56
[5]   Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait [J].
Blaya, JA ;
Herr, H .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2004, 12 (01) :24-31
[6]   Force encoding in muscle spindles during stretch of passive muscle [J].
Blum, Kyle P. ;
D'Incamps, Boris Lamotte ;
Zytnicki, Daniel ;
Ting, Lena H. .
PLOS COMPUTATIONAL BIOLOGY, 2017, 13 (09)
[7]  
Bregman D. J. J., 2011, THESIS
[8]   CONTRIBUTIONS OF CUTANEOUS AND JOINT RECEPTORS TO STATIC KNEE-POSITION SENSE IN MAN [J].
CLARK, FJ ;
HORCH, KW ;
BACH, SM ;
LARSON, GF .
JOURNAL OF NEUROPHYSIOLOGY, 1979, 42 (03) :877-888
[9]   VIBROTACTILE DIFFERENCE THRESHOLDS FOR INTENSITY AND EFFECT OF A MASKING STIMULUS [J].
CRAIG, JC .
PERCEPTION & PSYCHOPHYSICS, 1974, 15 (01) :123-127
[10]   Elastic coupling of limb joints enables faster bipedal walking [J].
Dean, J. C. ;
Kuo, A. D. .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2009, 6 (35) :561-573