Accuracy of computed tomography attenuation values in the characterization of pleural fluid: An ROC study

被引:40
作者
Nandalur, KR [1 ]
Hardie, AH
Bollampally, SR
Parmar, JP
Hagspiel, KD
机构
[1] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA 22903 USA
[2] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
关键词
pleural effusion; tomography; X-ray computed; exudates and transudates;
D O I
10.1016/j.acra.2005.05.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To assess the accuracy of computed tomography (CT) in characterizing pleural fluid based on attenuation values. Materials and Methods. Protocol was approved by the local institutional review board and informed consent was waived. We retrospectively analyzed 145 pleural effusions of 145 patients (mean/standard deviation age: 60.7/15.9 years; 69 females) who underwent CT of the thorax and diagnostic thoracentesis within 7 days of each other. Effusions were classified as transudates or exudates using laboratory markers based on Light's criteria. The mean Hounsfield units (HU) of an effusion was determined by a region of interest on the three slices with the greatest anteroposterior diameter. A receiver operating characteristic curve was constructed to determine threshold values for classification on the basis of mean HU and to examine overall accuracy, using the area under the curve (A,). Results. Of the 101 exudates and 44 transudates, the mean attenuation of exudates (17.1 HU/standard deviation 4.4) was significantly higher than transudates (12.5 HU/6.3), (P <.001). There was a modest but significant positive relationship between mean HU and laboratory markers, with the strongest relationship with pleural/serum protein (r = 0.57, P <.001) and total pleural protein (r = 0.56, P <.001). The overall accuracy of attenuation values for identifying exudates was moderate, Az = 0.775, standard error = 0.039, with the largest limitation being the overlap with transudates in the 10-20 HU range, which constituted 66% (90/145) of the total effusions measured. Conclusion. Although the mean attenuation of exudates is significantly higher than transudates, the clinical use of CT numbers to characterize pleural fluid is not recommended, as their accuracy is only moderate. Moreover, there is a notable overlap in attenuation values between transudates and exudates for a majority of effusions.
引用
收藏
页码:987 / 991
页数:5
相关论文
共 14 条
[1]  
ABRAHAMIAN FM, PLEURAL EFFUSION
[2]   PLEURAL EXUDATES AND TRANSUDATES - DIAGNOSIS WITH CONTRAST-ENHANCED CT [J].
AQUINO, SL ;
WEBB, WR ;
GUSHIKEN, BJ .
RADIOLOGY, 1994, 192 (03) :803-808
[3]   THE EVALUATION OF PLEURAL EFFUSION [J].
BARTTER, T ;
SANTARELLI, R ;
AKERS, SM ;
PRATTER, MR .
CHEST, 1994, 106 (04) :1209-1214
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   COMPARATIVE-ANALYSIS OF THE BIOCHEMICAL PARAMETERS USED TO DISTINGUISH BETWEEN PLEURAL TRANSUDATES AND EXUDATES [J].
BURGESS, LJ ;
MARITZ, FJ ;
TALJAARD, JJF .
CHEST, 1995, 107 (06) :1604-1609
[6]  
GOOD JT, 1980, CHEST, V78, P55, DOI 10.1378/chest.78.1.55
[7]   Ultrasound-guided thoracentesis - Is it a safer method? [J].
Jones, PW ;
Moyers, JP ;
Rogers, JT ;
Rodriguez, RM ;
Lee, YCG ;
Light, RW .
CHEST, 2003, 123 (02) :418-423
[8]   CT IN DIFFERENTIAL-DIAGNOSIS OF DIFFUSE PLEURAL DISEASE [J].
LEUNG, AN ;
MULLER, NL ;
MILLER, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :487-492
[9]   Pleural effusion [J].
Light, RW .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (25) :1971-1977
[10]   PLEURAL EFFUSIONS - DIAGNOSTIC SEPARATION OF TRANSUDATES AND EXUDATES [J].
LIGHT, RW ;
LUCHSINGER, PC ;
MACGREGOR, MI ;
BALL, WC .
ANNALS OF INTERNAL MEDICINE, 1972, 77 (04) :507-+