Safety and efficacy of frequency domain optical coherence tomography in pigs

被引:3
|
作者
Li, Xiankai [1 ,2 ]
Villard, Joseph W. [1 ]
Ouyang, Yongjian
Michalek, Joel E.
Jabara, Refat [3 ,4 ]
Sims, Dan [5 ]
Kemp, Nate [5 ]
Glynn, Tim [5 ]
Banas, Christopher [5 ]
Bailey, Steven R. [1 ]
Feldman, Marc D. [1 ,6 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Janey Briscoe Div Cardiol, San Antonio, TX 78229 USA
[2] Tongji Univ, Sch Med, Dept Cardiol, Shanghai Peoples Hosp 10, Shanghai 200092, Peoples R China
[3] Hadassah Hebrew Univ, Med Ctr, Jerusalem, Israel
[4] St Josephs Translat Res Inst, Atlanta, GA USA
[5] Volcano Corp, Billerica, MA USA
[6] S Texas Vet Hlth Care Syst, San Antonio, TX USA
关键词
optical coherence tomography; safety; efficacy; frequency domain; CORONARY STENT SYSTEM; NANOTHIN POLYZENE-F; ARTERY LESIONS; PLAQUES;
D O I
10.4244/EIJV7I4A80
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To determine the safety and efficacy of frequency domain OCT, which can scan at much higher rates and make it possible to avoid an occlusion balloon and image during an angiographic injection through guide catheter. The catheters have diameters ranging from 2.7 to 3.5 Fr. The presence of the imaging catheter increases fluid resistance to the injection of viscous solutions necessary for clearing the blood. Methods and results: The Volcano 3.5 Fr frequency domain OCT catheter system was investigated for safety in (a) n=10 porcine studies using acute and 30-day histology, and (b) for efficacy in n=9 in vivo porcine coronary arteries. We found: (a) frequency domain imaging is safe in the porcine model using histology as an endpoint; (b) the addition of a viscous contrast (iodixonal) to saline is superior for lumen clearance compared to saline alone; (c) hand injection, 4 ml/sec, and 6 ml/sec power injection all provided similar vessel wall clearance; (d) the anticipated loss of vessel wall visualisation with left main injection (due to half the injectate in the non-imaged vessel) was not evident in proximal and middle coronary artery OCT catheter positions. Conclusions: Frequency domain OCT is safe and efficacious in the porcine model.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 50 条
  • [31] Intravascular Frequency-Domain Optical Coherence Tomography Assessment of Carotid Artery Disease in Symptomatic and Asymptomatic Patients
    不详
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 675 - 684
  • [32] Frequency domain optical coherence tomography with subsequent depth resolved spectroscopic image analysis
    Kasseck, Christoph
    Jaedicke, Volker
    Gerhardt, Nils C.
    Welp, Hubert
    Hofmann, Martin R.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [33] New Concepts in Polypoidal Choroidal Vasculopathy Imaging: A Focus on Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Teo, Kelvin Y. C.
    Cheung, Gemmy C. M.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (02): : 165 - 171
  • [34] Complex Frequency Domain Doppler Optical Coherence Tomography Based on Phase Difference Resolved Technology
    Chen Hongqin
    Nan Nan
    Zhang Xi
    Chen Ziyang
    Pu Jixiong
    Sasaki, Osami
    Wang Xiangzhao
    ACTA OPTICA SINICA, 2019, 39 (11)
  • [35] Three-dimensional imaging of fibrous cap by frequency-domain optical coherence tomography
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Costa, Marco A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 547 - 549
  • [36] Clinical Studies of Frequency Domain Optical Coherence Tomography in the Coronary Arteries: The First 2000 Patients
    Petersen, Christopher
    Adler, Desmond
    Schmitt, Joseph
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [37] Substance identification by depth resolved spectroscopic pattern reconstruction in frequency domain optical coherence tomography
    Kasseck, Christoph
    Jaedicke, Volker
    Gerhardt, Nils C.
    Welp, Hubert
    Hofmann, Martin R.
    OPTICS COMMUNICATIONS, 2010, 283 (23) : 4816 - 4822
  • [38] System design and image processing algorithms for frequency domain optical coherence tomography in the coronary arteries
    Adler, Desmond C.
    Xu, Chenyang
    Petersen, Christopher
    Schmitt, Joseph M.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [39] 3D imaging of tomato seeds using frequency domain optical coherence tomography
    Fan, Chuanmao
    Yao, Gang
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY IV, 2012, 8369
  • [40] Numerical compensation of dispersion mismatch in discretely swept optical-frequency-domain-reffectometry optical coherence tomography
    Choi, Donghak
    Hiko-Oka, Hideaki
    Amano, Takuji
    Furukawa, Hiroyuki
    Kano, Fumiyoshi
    Nakanishi, Motoi
    Shimizu, Kimiya
    Ohbayashi, Kohji
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (07): : 6022 - 6027