Safety and efficacy of frequency domain optical coherence tomography in pigs

被引:3
|
作者
Li, Xiankai [1 ,2 ]
Villard, Joseph W. [1 ]
Ouyang, Yongjian
Michalek, Joel E.
Jabara, Refat [3 ,4 ]
Sims, Dan [5 ]
Kemp, Nate [5 ]
Glynn, Tim [5 ]
Banas, Christopher [5 ]
Bailey, Steven R. [1 ]
Feldman, Marc D. [1 ,6 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Janey Briscoe Div Cardiol, San Antonio, TX 78229 USA
[2] Tongji Univ, Sch Med, Dept Cardiol, Shanghai Peoples Hosp 10, Shanghai 200092, Peoples R China
[3] Hadassah Hebrew Univ, Med Ctr, Jerusalem, Israel
[4] St Josephs Translat Res Inst, Atlanta, GA USA
[5] Volcano Corp, Billerica, MA USA
[6] S Texas Vet Hlth Care Syst, San Antonio, TX USA
关键词
optical coherence tomography; safety; efficacy; frequency domain; CORONARY STENT SYSTEM; NANOTHIN POLYZENE-F; ARTERY LESIONS; PLAQUES;
D O I
10.4244/EIJV7I4A80
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To determine the safety and efficacy of frequency domain OCT, which can scan at much higher rates and make it possible to avoid an occlusion balloon and image during an angiographic injection through guide catheter. The catheters have diameters ranging from 2.7 to 3.5 Fr. The presence of the imaging catheter increases fluid resistance to the injection of viscous solutions necessary for clearing the blood. Methods and results: The Volcano 3.5 Fr frequency domain OCT catheter system was investigated for safety in (a) n=10 porcine studies using acute and 30-day histology, and (b) for efficacy in n=9 in vivo porcine coronary arteries. We found: (a) frequency domain imaging is safe in the porcine model using histology as an endpoint; (b) the addition of a viscous contrast (iodixonal) to saline is superior for lumen clearance compared to saline alone; (c) hand injection, 4 ml/sec, and 6 ml/sec power injection all provided similar vessel wall clearance; (d) the anticipated loss of vessel wall visualisation with left main injection (due to half the injectate in the non-imaged vessel) was not evident in proximal and middle coronary artery OCT catheter positions. Conclusions: Frequency domain OCT is safe and efficacious in the porcine model.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 50 条
  • [21] Ventricular Fibrillation During Optical Coherence Tomography/Optical Frequency Domain Imaging - A Large Single-Center Experience -
    Terada, Noriko
    Kuramochi, Tatsuhiko
    Sugiyama, Tomoyo
    Kanaji, Yoshihisa
    Hoshino, Masahiro
    Usui, Eisuke
    Yamaguchi, Masao
    Hada, Masahiro
    Misawa, Toru
    Sumino, Yohei
    Hirano, Hidenori
    Nogami, Kai
    Ueno, Hiroki
    Wakasa, Nobutaka
    Hosokawa, Masahiro
    Murai, Tadashi
    Lee, Tetsumin
    Yonetsu, Taishi
    Kobashi, Kazuhiko
    Kakuta, Tsunekazu
    CIRCULATION JOURNAL, 2020, 84 (02) : 178 - 185
  • [22] In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound
    Soo-Joong Kim
    Hang Lee
    Koji Kato
    Taishi Yonetsu
    Ik-Kyung Jang
    The International Journal of Cardiovascular Imaging, 2013, 29 : 967 - 975
  • [23] In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound
    Kim, Soo-Joong
    Lee, Hang
    Kato, Koji
    Yonetsu, Taishi
    Jang, Ik-Kyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) : 967 - 975
  • [24] Extending the Effective Ranging Depth of Spectral Domain Optical Coherence Tomography by Spatial Frequency Domain Multiplexing
    Wu, Tong
    Wang, Qingqing
    Liu, Youwen
    Wang, Jiming
    He, Chongjun
    Gu, Xiaorong
    APPLIED SCIENCES-BASEL, 2016, 6 (11):
  • [25] Multirate Spectral Domain Optical Coherence Tomography
    Gaur, Prabhav
    Grieco, Andrew
    Fainman, Yeshaiahu
    IEEE PHOTONICS JOURNAL, 2023, 15 (05):
  • [26] Synthetic Fourier Domain Optical Coherence Tomography
    Alexandrov, Sergey
    McAuley, Ryan
    Dey, Rajib
    Arangath, Anand
    Zhou, Yi
    Nolan, Andrew
    Owens, Peter
    Leahy, Martin
    ADVANCED PHOTONICS RESEARCH, 2024, 5 (04):
  • [27] Improved sensitivity of optical frequency domain reflectometry-optical coherence tomography using a semiconductor optical amplifier
    Jayavel, Pachamuthu
    Amano, Takuji
    Choi, DongHak
    Furukawa, Hiroyuki
    Hiro-Oka, Hideaki
    Asakai, Kota
    Ohbayashi, Kohji
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2006, 45 (46-50): : L1317 - L1319
  • [28] Frequency-domain optical coherence tomography based on minimum-phase functions
    Ozcan, A.
    Digonnet, M. J. F.
    Kino, G. S.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [29] Volumetric Characterization of Human Coronary Calcification by Frequency-Domain Optical Coherence Tomography
    Mehanna, Emile
    Bezerra, Hiram G.
    Prabhu, David
    Brandt, Eric
    Chamie, Daniel
    Yamamoto, Hirosada
    Attizzani, Guilherme F.
    Tahara, Satoko
    Van Ditzhuijzen, Nienke
    Fujino, Yusuke
    Kanaya, Tomoaki
    Stefano, Gregory
    Wang, Wei
    Gargesha, Madhusudhana
    Wilson, David
    Costa, Marco A.
    CIRCULATION JOURNAL, 2013, 77 (09) : 2334 - 2340
  • [30] An advanced algorithm for dispersion encoded full range frequency domain optical coherence tomography
    Koettig, Felix
    Cimalla, Peter
    Gaertner, Maria
    Koch, Edmund
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES VI, 2013, 8802