Echocardiographic evaluation during weaning from mechanical ventilation

被引:16
|
作者
Schifelbain, Luciele Medianeira [1 ]
Rios Vieira, Silvia Regina [2 ]
Brauner, Janete Salles [2 ,3 ]
Pacheco, Deise Mota [4 ]
Naujorks, Alexandre Antonio [4 ]
机构
[1] Hosp Caridade Dr Astrogildo de Azevedo, Intens Care Unit, Santa Maria, RS, Brazil
[2] HCPA, Intens Care Unit, Porto Alegre, RS, Brazil
[3] Hosp Nossa Senhora da Conceicao, Porto Alegre, RS, Brazil
[4] Hosp Caridade Dr Astrogildo de Azevedo, Dept Cardiol, Santa Maria, RS, Brazil
关键词
Echocardiography; Doppler echocardiogram; Cardiorespiratory variables; Ventilator weaning; Artificial ventilation; MYOCARDIAL-ISCHEMIA; FAILURE;
D O I
10.1590/S1807-59322011000100019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION: Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. OBJECTIVES: To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T-tube; and comparing patient subgroups: success vs. failure in weaning. METHODS: Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T-tube. Pressure support ventilation vs. T-tube and weaning success vs. failure were compared using ANOVA and Student's t-test. The level of significance was p < 0.05. RESULTS: Twenty-four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T-tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. CONCLUSION: No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T-tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients.
引用
收藏
页码:107 / 111
页数:5
相关论文
共 50 条
  • [31] Critical illness-related corticosteroid insufficiency during difficult weaning from mechanical ventilation
    Bagate, Francois
    Bedet, Alexandre
    Tomberli, Francoise
    Boissier, Florence
    Razazi, Keyvan
    de Prost, Nicolas
    Carteaux, Guillaume
    Mekontso Dessap, Armand
    ANNALS OF INTENSIVE CARE, 2021, 11 (01)
  • [32] Respiratory Rate as a Predictor of Weaning Failure from Mechanical Ventilation
    Santos Lima, Emidio Jorge
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2013, 63 (01): : 1 - 12
  • [33] Clinical Practice Guidelines for Early Weaning from Mechanical Ventilation
    Pereira Valdes, Eddy
    MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS, 2009, 7 (01): : 6 - 10
  • [34] Obesity and Weaning from Mechanical Ventilation-An Exploratory Study
    Obi, Ogugua Ndili
    Mazer, Mark
    Bangley, Charles
    Kassabo, Zuheir
    Saadah, Khalid
    Trainor, Wayne
    Stephens, Kenneth
    Rice, Patricia L.
    Shaw, Robert
    CLINICAL MEDICINE INSIGHTS-CIRCULATORY RESPIRATORY AND PULMONARY MEDICINE, 2018, 12
  • [35] Diaphragm ultrasound in patients with prolonged weaning from mechanical ventilation
    Fritsch, Sebastian Johannes
    Siemer, Anna Grosse
    Dreher, Michael
    Marx, Gernot
    Bickenbach, Johannes
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (05) : 3248 - 3263
  • [36] Factors influencing weaning from mechanical ventilation in neurological and neurosurgical early rehabilitation patients
    Schmidt, Simone B.
    Boltzmann, Melanie
    Bertram, Markus
    Bucka, Christoph
    Hartwich, Michael
    Joebges, Michael
    Ketter, Guido
    Leineweber, Bernd
    Mertl-Roetzer, Marion
    Nowak, Dennis A.
    Platz, Thomas
    Scheidtmann, Klaus
    Thomas, Randall
    von Rosen, Friedrich
    Wallesch, Claus W.
    Woldag, Hartwig
    Peschel, Peter
    Mehrholz, Jan
    Pohl, Marcus
    Rollnik, Jens D.
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2018, 54 (06) : 939 - 946
  • [37] Value of Combination of Heart, Lung, and Diaphragm Ultrasound in Predicting Weaning Outcome of Mechanical Ventilation
    Xu, Xia
    Wu, Rong
    Zhang, Ya-jiang
    Li, Hui-wen
    He, Xiu-hong
    Wang, Shu-min
    MEDICAL SCIENCE MONITOR, 2020, 26
  • [38] Effects of the use of mechanical ventilation weaning protocol in the Coronary Care Unit: randomized study
    Piotto, Raquel Ferrari
    Maia, Lilia Nigro
    Machado, Mauricio de Nassau
    Orrico, Suzana Perez
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2011, 26 (02): : 213 - 221
  • [39] Automatic continuous P0.1 measurements during weaning from mechanical ventilation: a clinical study
    Flora, Delamaire
    Adel, Maamar
    Pauline, Guillot
    Quentin, Quelven
    Valentin, Coirier
    Benoit, Painvin
    Jean-Marc, Tadie
    Nicolas, Terzi
    Arnaud, Gacouin
    ANNALS OF INTENSIVE CARE, 2025, 15 (01):
  • [40] Weaning failure from mechanical ventilation due to hypertrophic obstructive cardiomyopathy
    Adamopoulos, C
    Tsagourias, M
    Arvaniti, K
    Veroniki, F
    Matamis, D
    INTENSIVE CARE MEDICINE, 2005, 31 (05) : 734 - 737