Volar-locking plate versus external fixator in the management of distal radius fractures: An isokinetic study

被引:6
|
作者
Dundar, Abdulrahim [1 ]
Cankaya, Deniz [2 ]
Karakus, Dilek [3 ]
Tabak, Abdullah Yalcin [2 ]
机构
[1] Hitit Univ Training & Res Hosp, Dept Orthopaed & Traumatol, Corum, Turkey
[2] Gulhane Training & Res Hosp, Dept Orthopaed & Traumatol, Ankara, Turkey
[3] Ordu Univ Training & Res Hosp, Dept Phys Med & Rehabil, Ordu, Turkey
来源
ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY | 2022年 / 28卷 / 08期
关键词
Distal radius fracture; external fixation; isokinetic evaluation; volar plate; DISPLACED INTRAARTICULAR FRACTURES; OPEN REDUCTION; GRIP STRENGTH; RELIABILITY; MOTION;
D O I
10.14744/tjtes.2021.72606
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The aim of this study was to compare the clinical and isokinetic evaluation of distal radius fractures treated by volar locking plate (VLP) and external fixator. METHODS: The study included fifty patients with distal radius fracture type C1/C2/C3. Twenty-seven patients (12 men, 15 women; mean age 49.5 +/- 4.42) underwent open reduction and VLP fixation, and 23 patients (10 men, 13 women; 52.1 +/- 4.6) underwent closed reduction and external fixation. The follow-up period was at least 12 months and the mean following time was 13.5 +/- 1.02 (12-15) months. The functional parameters measured were range of motion (ROM) and grip strength. Radiographic parameters (radial inclination, palmar tilt, and radial height) and isokinetic evaluation were measured at the 6 months and at the final follow-up after surgery. The isokinetic test was done at the speed of 60 degrees/s. The non-fractured arm was tested first and all results were also expressed as a percentage of that on the normal side. Wrist scores according to the disability of the arm, shoulder, and hand (DASH) questionnaire were used. RESULTS: The DASH scores, grip strength, and palmar flexion were better in VLP group at the 6 months (p<0.05). However, there were no differences between two groups at the one year (p=0.79). Isokinetic evaluation of the VLP showed that peak pronation torque and total pronation work were better than external fixation at the 6 month (p<0.05). At the final of follow-up was seen no significant differences between two groups (p=0.11). CONCLUSION: We looked at external fixation and locked volar plates in a prospective study and we found an improved range of movement and isokinetic evaluation outcome at 6 months after locked plating, but there were no differences between two groups at the final of follow-up. Our study showed no evidence for the superiority of one treatment over the other at the final follow-up.
引用
收藏
页码:1156 / 1163
页数:8
相关论文
共 50 条
  • [41] Treatment of distal radius fractures with the external fixator
    Scholz, A. O.
    Schoepp, C.
    Boehm, H-J
    Kortmann, H-R
    TRAUMA UND BERUFSKRANKHEIT, 2007, 9 (01) : 19 - 23
  • [42] Comparative clinical study of locking screws versus smooth locking pegs in volar plating of distal radius fractures
    Boretto, J. G.
    Pacher, N.
    Giunta, D.
    Gallucci, G. L.
    Alfie, V.
    De Carli, P.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (07) : 755 - 760
  • [43] Outcome of External Fixator in Distal Radius Fractures
    Iqbal, Mohammad Faheem
    Ali, Sikandar
    Aziz, Shaheryar
    Khan, Dildar Ahmed
    Qureshi, Abdul Samad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (01): : 34 - 35
  • [44] Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
    Shao, Jin
    Kong, De-Ce
    Yang, Tie-Yi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08): : 16230 - +
  • [45] Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study
    Landgren, Marcus
    Abramo, Antonio
    Geijer, Mats
    Kopylov, Philippe
    Tagil, Magnus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (03): : 156 - 165
  • [46] Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study
    Wei Liu
    Lihui Yang
    Xiaochuan Kong
    Likun An
    Gang Hong
    Zicheng Guo
    Lei Zang
    BMC Musculoskeletal Disorders, 18
  • [47] Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes
    Calbiyik, Murat
    Ipek, Deniz
    MEDICAL SCIENCE MONITOR, 2018, 24 : 602 - 613
  • [48] Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study
    Liu, Wei
    Yang, Lihui
    Kong, Xiaochuan
    An, Likun
    Hong, Gang
    Guo, Zicheng
    Zang, Lei
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18 : 1 - 6
  • [49] Biomechanical Comparison of Locking versus Nonlocking Volar and Dorsal T-Plates for Fixation of Dorsally Comminuted Distal Radius Fractures
    Gondusky, Joseph S.
    Carney, Joseph
    Erpenbach, Jonathan
    Robertson, Claire
    Mahar, Andrew
    Oka, Richard
    Thompson, Michael
    Mazurek, Michael
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) : 44 - 50
  • [50] Biomechanics of Subcutaneous Locked Plating Versus Burke Plate and External Fixator for Comminuted Distal Radius Fractures
    Fleifel, Dominik
    Pytiak, Andrew V.
    Jin, Xin
    Cizmic, Zlatan
    Vaidya, Rahul
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)