Volar-locking plate versus external fixator in the management of distal radius fractures: An isokinetic study

被引:6
|
作者
Dundar, Abdulrahim [1 ]
Cankaya, Deniz [2 ]
Karakus, Dilek [3 ]
Tabak, Abdullah Yalcin [2 ]
机构
[1] Hitit Univ Training & Res Hosp, Dept Orthopaed & Traumatol, Corum, Turkey
[2] Gulhane Training & Res Hosp, Dept Orthopaed & Traumatol, Ankara, Turkey
[3] Ordu Univ Training & Res Hosp, Dept Phys Med & Rehabil, Ordu, Turkey
来源
ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY | 2022年 / 28卷 / 08期
关键词
Distal radius fracture; external fixation; isokinetic evaluation; volar plate; DISPLACED INTRAARTICULAR FRACTURES; OPEN REDUCTION; GRIP STRENGTH; RELIABILITY; MOTION;
D O I
10.14744/tjtes.2021.72606
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The aim of this study was to compare the clinical and isokinetic evaluation of distal radius fractures treated by volar locking plate (VLP) and external fixator. METHODS: The study included fifty patients with distal radius fracture type C1/C2/C3. Twenty-seven patients (12 men, 15 women; mean age 49.5 +/- 4.42) underwent open reduction and VLP fixation, and 23 patients (10 men, 13 women; 52.1 +/- 4.6) underwent closed reduction and external fixation. The follow-up period was at least 12 months and the mean following time was 13.5 +/- 1.02 (12-15) months. The functional parameters measured were range of motion (ROM) and grip strength. Radiographic parameters (radial inclination, palmar tilt, and radial height) and isokinetic evaluation were measured at the 6 months and at the final follow-up after surgery. The isokinetic test was done at the speed of 60 degrees/s. The non-fractured arm was tested first and all results were also expressed as a percentage of that on the normal side. Wrist scores according to the disability of the arm, shoulder, and hand (DASH) questionnaire were used. RESULTS: The DASH scores, grip strength, and palmar flexion were better in VLP group at the 6 months (p<0.05). However, there were no differences between two groups at the one year (p=0.79). Isokinetic evaluation of the VLP showed that peak pronation torque and total pronation work were better than external fixation at the 6 month (p<0.05). At the final of follow-up was seen no significant differences between two groups (p=0.11). CONCLUSION: We looked at external fixation and locked volar plates in a prospective study and we found an improved range of movement and isokinetic evaluation outcome at 6 months after locked plating, but there were no differences between two groups at the final of follow-up. Our study showed no evidence for the superiority of one treatment over the other at the final follow-up.
引用
收藏
页码:1156 / 1163
页数:8
相关论文
共 50 条
  • [31] Volar locking plate vs epibloc system for distal radius fractures in the elderly
    Solarino, Giuseppe
    Vicenti, Giovanni
    Abate, Antonella
    Carrozzo, Massimiliano
    Picca, Girolamo
    Colella, Antonio
    Moretti, Biagio
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S84 - S90
  • [32] Teardrop Alignment Changes After Volar Locking Plate Fixation of Distal Radius Fractures With Volar Ulnar Fragments
    McCarty, Justin C.
    Cross, Rachel E.
    Laane, Charlotte L. E.
    Hoftiezer, Yannick Albert J.
    Gavagnin, Aquiles
    Regazzoni, Pietro
    Dell'Oca, Alberto Fernandez
    Jupiter, Jesse B.
    Bhashyam, Abhiram R.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024,
  • [33] Evaluation of the Coronal Malposition of the Volar Locking Plate in the Treatment of Distal Radius Fractures
    Usta, Emirhan
    Akpolat, Ahmet O.
    Kahraman, Ahmet N.
    Kara, Adnan
    Oc, Yunus
    Kilinc, Bekir E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [34] Volar locking plate (VLP) versus non-locking plate (NLP) in the treatment of die-punch fractures of the distal radius, an observational study
    Zhang, Xiong
    Hu, Chunhe
    Yu, Kunlun
    Bai, Jiangbo
    Tian, Dehu
    Xu, Yi
    Zhang, Bing
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 34 : 142 - 147
  • [35] Volar plate versus k-wire fixation of distal radius fractures
    Brennan, Stephen A.
    Kiernan, Christine
    Beecher, Suzanne
    O'Reilly, Rory T.
    Devitt, Brian M.
    Kearns, Stephen R.
    O'Sullivan, Michael E.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (02): : 372 - 376
  • [36] Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis
    Peng, Fei
    Liu, Yuan-xiang
    Wan, Zhen-yu
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (02) : 158 - 167
  • [37] Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study
    Lv, Zhenmu
    Zhao, Yan
    Zhang, Yingze
    Wang, Qiusheng
    Ding, Wenyuan
    Shen, Yong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (10): : 14721 - 14729
  • [38] External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes
    Shukla R.
    Jain R.K.
    Sharma N.K.
    Kumar R.
    Journal of Orthopaedics and Traumatology, 2014, 15 (4) : 265 - 270
  • [39] Radiological, Clinical, and Functional Outcomes of Combined Dorsal and Volar Locking Plate Osteosynthesis for Complex Distal Radius Fractures
    Luedi, Simona
    Kurz, Charlotte
    Deforth, Manja
    Ghafoor, Haval
    Haefeli, Mathias
    Honigmann, Philipp
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (04): : 377 - 387
  • [40] Treatment of unstable distal radius fractures: non-invasive dynamic external fixator versus volar locking plate - functional and radiological outcome in a prospective case-controlled series
    Bajwa, Ali S.
    Rammappa, Manju
    Lee, Ling
    Nanda, Rajesh
    SICOT-J, 2015, 1