Evaluation of the cobas 4800 CT/NG test for detecting Chlamydia trachomatis

被引:3
|
作者
Parra, Manuel [1 ]
Palomares, Jose Carlos [1 ]
Bernal, Samuel [1 ]
Sivianes, Nieves [1 ]
Perez, Luis [1 ]
Pueyo, Isabel [2 ]
Almeida, Carmen [3 ]
Martin-Mazuelos, Estrella [1 ]
机构
[1] Hosp Univ Valme, Mol Microbiol Lab, Unidad Clin Enfermedades Infecciosas & Microbiol, Seville, Spain
[2] Ctr Infecc Transmis Sexual, Seville, Spain
[3] Hosp Univ Valme, Unidad Invest, Seville, Spain
来源
ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA | 2011年 / 29卷 / 06期
关键词
Chlamydia trachomatis; cobas; 4800; Cobas AMPLICOR; Urine; Exudado urogenital exudate; PELVIC-INFLAMMATORY-DISEASE; ACID AMPLIFICATION TESTS; NEISSERIA-GONORRHOEAE; CERVICAL-CANCER; INFECTIONS; SEQUENCE; VARIANT;
D O I
10.1016/j.eimc.2011.01.016
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Introduction: To evaluate the new automated system cobas 4800 CT/NG test for detection of Chlamydia trachomatis in urogenital specimens. Material and methods: We analyzed 696 specimens (488 swabs from urethral or cervical specimens, and 208 urines) to detect C. trachomatis. The results of the cobas 4800 CT/NG test (c4800) were compared to those obtained with Cobas AMPLICOR CT/NG test (CAM). Discordant results were analyzed with a conventional PCR assay and microchip electrophoresis system in agarose gel, MultiNA. Results: We made two simultaneous analyses. In the first one, we compared the results obtained with swab specimens using the c4800 system and CAM. In this case, the sensitivity, the specifity, the positive and negative predictive values (PPV and NPV) were: 77.9%, 100%, 100% and 96% respectively. In the second one, we compared the results obtained for urine and its corresponding swab specimens on the c4800. The values obtained were: 100%, 98.9%, 92.9% and 100% respectively. The kappa values of these comparisons were: 0.857 for swab specimens on the c4800 and CAM, and 0.957 for urine versus swab specimens on the c4800. Conclusions: The results obtained with c4800 system were completely comparable with those obtained with CAM. We also noted an excellent correlation with these results when we compared swab specimens with their urine samples in the c4800 system. Therefore this sample type could be used routinely to diagnose infections in men and women. (C) 2010 Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [21] Impact of improper sample handling on Cobas CT/NG testing platform with dual swab sample collection kit for detecting Chlamydia trachomatis and Neisseria gonorrhoeae
    Navarathna, Dhammika H.
    Sayers, Kelle B.
    Murray, Derek C.
    MICROBIOLOGY SPECTRUM, 2024, 12 (01):
  • [22] Performance of the NG OligoGen kit for the diagnosis of Neisseria gonorrhoeae: comparison with cobas 4800 assay
    Parra-Sanchez, M.
    Garcia-Rey, S.
    Marcuello, A.
    Zakariya-Yousef, I.
    Bernal, S.
    Pueyo, I.
    Martin-Mazuelos, E.
    Palomares, J. C.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2016, 84 (01) : 4 - 6
  • [23] Performance of the Abbott RealTime CT/NG for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Gaydos, C. A.
    Cartwright, C. P.
    Colaninno, P.
    Welsch, J.
    Holden, J.
    Ho, S. Y.
    Webb, E. M.
    Anderson, C.
    Bertuzis, R.
    Zhang, L.
    Miller, T.
    Leckie, G.
    Abravaya, K.
    Robinson, J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (09) : 3236 - 3243
  • [24] Comparison of urine and cervical samples for detecting human papillomavirus (HPV) with the Cobas 4800 HPV test
    Bernal, Samuel
    Palomares, Jose C.
    Artura, Antonio
    Parra, Manuel
    Cabezas, Jose L.
    Robles, Antonio
    Martin Mazuelos, Estrella
    JOURNAL OF CLINICAL VIROLOGY, 2014, 61 (04) : 548 - 552
  • [25] Swabs (dry or collected in universal transport medium) and semen can be used for the detection of Chlamydia trachomatis using the cobas 4800 system
    Le Roy, Chloe
    Papaxanthos, Aline
    Liesenfeld, Oliver
    Mehats, Virginie
    Clerc, Maithe
    Bebear, Cecile
    de Barbeyrac, Bertille
    JOURNAL OF MEDICAL MICROBIOLOGY, 2013, 62 : 217 - 222
  • [26] Performance of the Cepheid CT/NG Xpert Rapid PCR Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Gaydos, Charlotte A.
    Van der Pol, Barbara
    Jett-Goheen, Mary
    Barnes, Mathilda
    Quinn, Nicole
    Clark, Carey
    Daniel, Grace E.
    Dixon, Paula B.
    Hook, Edward W., III
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (06) : 1666 - 1672
  • [27] Performance Evaluation of the LabGenius C-CT/NG-BMX Assay for Chlamydia trachomatis and Neisseria gonorrhoeae Detection
    Lim, Yong Kwan
    Kweon, Oh Joo
    Park, Ae Ja
    Kim, Hongkyung
    Yoon, Sumi
    Kim, Tae-Hyoung
    Lee, Mi-Kyung
    ANNALS OF LABORATORY MEDICINE, 2025, 45 (02) : 218 - 222
  • [28] Meta-analysis of the Cepheid Xpert® CT/NG assay for extragenital detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) infections
    Bristow, Claire C.
    Morris, Sheldon R.
    Little, Susan J.
    Mehta, Sanjay R.
    Klausner, Jeffrey D.
    SEXUAL HEALTH, 2019, 16 (04) : 314 - 319
  • [29] Analytical Evaluation of GeneXpert CT/NG, the First Genetic Point-of-Care Assay for Simultaneous Detection of Neisseria gonorrhoeae and Chlamydia trachomatis
    Tabrizi, Sepehr N.
    Unemo, Magnus
    Golparian, Daniel
    Twin, Jimmy
    Limnios, Athena E.
    Lahra, Monica
    Guy, Rebecca
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (06) : 1945 - 1947
  • [30] A previously documented Neisseria macacae isolate providing a false-positive result with Roche cobas 4800 CT/NG does not cross-react with the later generation cobas 6800 CT/NG assay
    Pryce, Todd M.
    Bromhead, Collette
    Whiley, David M.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2023, 42 (01) : 121 - 123