Evaluation of the cobas 4800 CT/NG test for detecting Chlamydia trachomatis

被引:3
|
作者
Parra, Manuel [1 ]
Palomares, Jose Carlos [1 ]
Bernal, Samuel [1 ]
Sivianes, Nieves [1 ]
Perez, Luis [1 ]
Pueyo, Isabel [2 ]
Almeida, Carmen [3 ]
Martin-Mazuelos, Estrella [1 ]
机构
[1] Hosp Univ Valme, Mol Microbiol Lab, Unidad Clin Enfermedades Infecciosas & Microbiol, Seville, Spain
[2] Ctr Infecc Transmis Sexual, Seville, Spain
[3] Hosp Univ Valme, Unidad Invest, Seville, Spain
来源
ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA | 2011年 / 29卷 / 06期
关键词
Chlamydia trachomatis; cobas; 4800; Cobas AMPLICOR; Urine; Exudado urogenital exudate; PELVIC-INFLAMMATORY-DISEASE; ACID AMPLIFICATION TESTS; NEISSERIA-GONORRHOEAE; CERVICAL-CANCER; INFECTIONS; SEQUENCE; VARIANT;
D O I
10.1016/j.eimc.2011.01.016
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Introduction: To evaluate the new automated system cobas 4800 CT/NG test for detection of Chlamydia trachomatis in urogenital specimens. Material and methods: We analyzed 696 specimens (488 swabs from urethral or cervical specimens, and 208 urines) to detect C. trachomatis. The results of the cobas 4800 CT/NG test (c4800) were compared to those obtained with Cobas AMPLICOR CT/NG test (CAM). Discordant results were analyzed with a conventional PCR assay and microchip electrophoresis system in agarose gel, MultiNA. Results: We made two simultaneous analyses. In the first one, we compared the results obtained with swab specimens using the c4800 system and CAM. In this case, the sensitivity, the specifity, the positive and negative predictive values (PPV and NPV) were: 77.9%, 100%, 100% and 96% respectively. In the second one, we compared the results obtained for urine and its corresponding swab specimens on the c4800. The values obtained were: 100%, 98.9%, 92.9% and 100% respectively. The kappa values of these comparisons were: 0.857 for swab specimens on the c4800 and CAM, and 0.957 for urine versus swab specimens on the c4800. Conclusions: The results obtained with c4800 system were completely comparable with those obtained with CAM. We also noted an excellent correlation with these results when we compared swab specimens with their urine samples in the c4800 system. Therefore this sample type could be used routinely to diagnose infections in men and women. (C) 2010 Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [1] Evaluation of the cobas 4800 CT/NG Test for detecting Chlamydia trachomatis and Neisseria gonorrhoeae DNA in urogenital swabs and urine specimens
    Parra-Sanchez, Manuel
    Carlos Palomares, Jose
    Bernal, Samuel
    Trinidad Gonzalez, Maria
    Sivianes, Nieves
    Perez, Luis
    Pueyo, Isabel
    Martin-Mazuelos, Estrella
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 74 (04) : 338 - 342
  • [2] Despite Excellent Test Characteristics of the cobas 4800 CT/NG Assay, Detection of Oropharyngeal Chlamydia trachomatis and Neisseria gonorrhoeae Remains Challenging
    van Niekerk, J. M.
    van der Veer, B. M. J. W.
    Hoebe, C. J. P. A.
    van de Bovenkamp, J.
    van Herk, C.
    van Loo, I. H. M.
    van Alphen, L. B.
    Wolffs, P. F. G.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (02)
  • [3] Vaginal Swabs Are the Optimal Specimen for Detection of Genital Chlamydia trachomatis or Neisseria gonorrhoeae Using the Cobas 4800 CT/NG Test
    Van Der Pol, Barbara
    Taylor, Stephanie N.
    Liesenfeld, Oliver
    Williams, James A.
    Hook, Edward W., III
    SEXUALLY TRANSMITTED DISEASES, 2013, 40 (03) : 247 - 250
  • [4] Comparison of the CT OligoGen kit with cobas 4800 assay for detection of Chlamydia trachomatis
    Parra-Sanchez, Manuel
    Marcuello-Lopez, Ana
    Garcia-Rey, Silvia
    Zakariya-Yousef, Ismail
    Sivianes-Valdecantos, Nieves
    Sierra-Atienza, Celestina
    Bernal-Martinez, Samuel
    Pueyo-Rodrigez, Isabel
    Martin-Mazuelos, Estrella
    Carlos Palomares-Folia, Jose
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2015, 33 (10): : 642 - 645
  • [5] Cobas® 4800: a fully automated system for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Van der Pol, Barbara
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2013, 13 (02) : 131 - 140
  • [6] Detection of Neisseria gonorrhoeae or Chlamydia trachomatis from oral wash specimens using the Abbott RealTime CT/NG assay and the Cobas 4800 CT/NG assay: A prospective study
    Matsumoto, Masahiro
    Hamasuna, Ryoichi
    Le, Phuong Thi
    Fujimoto, Naohiro
    Matsumoto, Tetsuro
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2022, 28 (04) : 480 - 485
  • [7] Evaluation of the Roche cobas® CT/NG Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Male Urine
    Taylor, Stephanie N.
    Liesenfeld, Oliver
    Lillis, Rebecca A.
    Body, Barbara A.
    Nye, Melinda
    Williams, James
    Eisenhut, Carol
    Hook, Edward W., III
    Van der Pol, Barbara
    SEXUALLY TRANSMITTED DISEASES, 2012, 39 (07) : 543 - 549
  • [8] Evaluation of the Performance of the Cobas CT/NG Test for Use on the Cobas 6800/8800 Systems for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Male and Female Urogenital Samples
    Van Der Pol, Barbara
    Fife, Kenneth
    Taylor, Stephanie N.
    Nye, Melinda B.
    Chavoustie, Steven E.
    Eisenberg, David L.
    Crane, LaShonda
    Hirsch, Gregory
    Arcenas, Rodney
    Marlowe, Elizabeth M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2019, 57 (04)
  • [9] A profile of the cobas® CT/NG assay on the cobas® 6800/8800 system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Van Der Pol, Barbara
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2020, 20 (04) : 375 - 380
  • [10] Is confirmatory testing of Roche cobas 4800 CT/NG test Neisseria gonorrhoeae positive samples required? Comparison of the Roche cobas 4800 CT/NG test with an opa/pap duplex assay for the detection of N gonorrhoeae
    Perry, Michael D.
    Jones, Rachel N.
    Corden, Sally A.
    SEXUALLY TRANSMITTED INFECTIONS, 2014, 90 (04) : 303 - 308