Novel handheld PET probes provide intraoperative localization of PET-avid lymph nodes

被引:2
作者
Gonzalez, Segundo J. [1 ]
Wong, Joyce [1 ]
Gonzalez, Lorena [1 ]
Brader, Peter [2 ]
Zakowski, Maureen [3 ]
Goenen, Mithat [4 ]
Fong, Yuman [1 ]
Strong, Vivian E. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Surg, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10065 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10065 USA
[4] Mem Sloan Kettering Canc Ctr, Dept Epidemiol & Biostat, New York, NY 10065 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2011年 / 25卷 / 10期
关键词
PET probes; Minimally invasive surgery; Intraoperative probe; Beta rays; High-energy gamma rays; NUDE RAT MODEL; BREAST-CANCER; GAMMA-PROBE; BIOPSY; CARCINOMA; POSITRON; SURGERY;
D O I
10.1007/s00464-011-1696-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction The accurate intraoperative localization of malignant nodes can pose a challenge to the surgical oncologist. Positron emission tomography (PET) scanning has significantly increased our ability to detect suspicious lesions. We investigated the ability of a novel, handheld tool to evaluate suspicious nodes intraoperatively and to correlate its findings with those seen on preoperative PET scan. Methods Ten nude rats were inoculated with a lymphogenic mesothelioma tumor line and followed weekly with PET scan studies. When suspicious lymph nodes were found, animals were dissected and the intraoperative amount of tissue radiation was analyzed as "tumor-to-background ratio" (TBR) using the PET probes. Results The intraoperative probe was used to guide dissections and select high-risk nodes based on their specific radiotracer uptake. A total of 52 nodes were harvested; eight of these were suspicious on preoperative PET scan studies. Using a TBR of 2.5, the intraoperative probes were able to localize all suspicious nodes previously seen on PET scan. Both gamma (sensitivity: 100%; specificity: 86%; positive predictive value (PPV): 57%; negative predictive value (NPV): 100%) and beta (sensitivity: 88%; specificity: 91%; PPV: 64%; NPV: 98%) probes showed an excellent area under the curve (AUC) in the receiver operating characteristic analysis (ROC). Both probes had an AUC of 0.95 for localizing suspicious nodes on PET scan. Furthermore, the AUC for detecting malignancy for the gamma probe was 0.90 (95% confidence interval (CI), 0.83-0.99), and for the beta probe it was 0.97 (95% CI, 0.94-1.0), suggesting a better performance of the beta probe for detecting malignancy. Conclusions This novel tool may be used synergistically with the PET scan examination to maximize intraoperative nodal selection and sampling.
引用
收藏
页码:3214 / 3221
页数:8
相关论文
共 20 条
[1]  
BELLAMY E, 2007, CANC IMAGING, V7, pS116
[2]   Sentinel lymph nodes in breast cancer after 10 years: rethinking basic principles [J].
Bleiweiss, Ira J. .
LANCET ONCOLOGY, 2006, 7 (08) :686-692
[3]  
Buck AK, 2004, J NUCL MED, V45, P461
[4]   Novel perioperative imaging with 18F-FDG PET/CT and intraoperative 18F-FDG detection using a handheld gamma probe in recurrent ovarian cancer [J].
Cohn, David E. ;
Hall, Nathan C. ;
Povoski, Stephen P. ;
Seamon, Leigh G. ;
Farrar, William B. ;
Martin, Edward W., Jr. .
GYNECOLOGIC ONCOLOGY, 2008, 110 (02) :152-157
[5]   INTRAOPERATIVE BETA-PROBE - A DEVICE FOR DETECTING TISSUE LABELED WITH POSITRON OR ELECTRON EMITTING ISOTOPES DURING SURGERY [J].
DAGHIGHIAN, F ;
MAZZIOTTA, JC ;
HOFFMAN, EJ ;
SHENDEROV, P ;
ESHAGHIAN, B ;
SIEGEL, S ;
PHELPS, ME .
MEDICAL PHYSICS, 1994, 21 (01) :153-157
[6]   8-YEAR RESULTS OF A RANDOMIZED CLINICAL-TRIAL COMPARING TOTAL MASTECTOMY AND LUMPECTOMY WITH OR WITHOUT IRRADIATION IN THE TREATMENT OF BREAST-CANCER [J].
FISHER, B ;
REDMOND, C ;
POISSON, R ;
MARGOLESE, R ;
WOLMARK, N ;
WICKERHAM, L ;
FISHER, E ;
DEUTSCH, M ;
CAPLAN, R ;
PILCH, Y ;
GLASS, A ;
SHIBATA, H ;
LERNER, H ;
TERZ, J ;
SIDOROVICH, L .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (13) :822-828
[7]   Molecular imaging of cancer with positron emission tomography [J].
Gambhir, SS .
NATURE REVIEWS CANCER, 2002, 2 (09) :683-693
[8]  
Gonen M., 2007, Analyzing receiver operating characteristic curves with SAS
[9]   PET-Probe: Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery [J].
Gulec, Seza A. ;
Daghighian, Farhad ;
Essner, Richard .
ANNALS OF SURGICAL ONCOLOGY, 2016, 23 :9020-9027
[10]   PET probe-guided surgery [J].
Gulec, Seza A. .
JOURNAL OF SURGICAL ONCOLOGY, 2007, 96 (04) :353-357